Analysis of serum transthyretin by on-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry using magnetic beads

被引:21
|
作者
Pero-Gascon, Roger [1 ]
Pont, Laura [1 ]
Benavente, Fernando [1 ]
Barbosa, Jose [1 ]
Sanz-Nebot, Victoria [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
Capillary electrophoresis; Magnetic beads; Mass spectrometry; On-line immunopurification; Transthyretin; CEREBROSPINAL-FLUID; OPIOID-PEPTIDES; MICROCHIP ELECTROPHORESIS; HUMAN PLASMA; PROTEIN; BIOMOLECULES; PREALBUMIN; BIOMARKERS; ISOFORMS; SORBENT;
D O I
10.1002/elps.201500495
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, an on-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry (IA-SPE-CE-MS) method using magnetic beads (MBs) is described for the analysis of serum transthyretin (TTR), which is a protein related to different types of amyloidosis. First, purification of TTR from serum was investigated by off-line immunoprecipitation and CE-MS. The suitability of three Protein A (ProA) MBs (Protein A Ultrarapid Agarose (TM) ( UAPA), Dynabeads (R) Protein A (DyPA) and SiMAG-Protein A (SiPA) and AffiAmino Ultrarapid Agarose (TM) (UAAF) MBs to prepare an IA sorbent with a polyclonal antibody (Ab) against TTR, was studied. In all cases, results were repeatable and it was possible the identification and the quantitation of the relative abundance of the six most abundant TTR proteoforms. Although recoveries were the best with UAPA MBs, UAAF MBs were preferred for on-line immunopurification because Ab was not eluted from the MBs. Under the optimized conditions with standards in IA-SPE-CEMS, microcartridge lifetime (> 20 analyses/day) and repeatability (2.9 and 4.3% RSD for migration times and peak areas) were good, the method was linear between 5 and 25 mu g/mL and LOD was around 1 mu g/mL (25 times lower than by CE-MS, approximate to 25 mu g/mL). A simple off-line sample pretreatment based on precipitation of the most abundant proteins with 5% (v/v) of phenol was necessary to clean-up serum samples. The potential of the on-line method to screen for familial amyloidotic polyneuropathy type I (FAP-I), which is the most common hereditary systemic amyloidosis, was demonstrated analysing serum samples from healthy controls and FAP-I patients.
引用
收藏
页码:1220 / 1231
页数:12
相关论文
共 50 条
  • [21] Determination of a lectin protein allergen in food by on-line aptamer affinity solid-phase extraction capillary electrophoresis-mass spectrometry
    Vergara-Barberan, Maria
    Simo-Alfonso, Ernesto Francisco
    Herrero-Martinez, Jose Manuel
    Benavente, Fernando
    MICROCHEMICAL JOURNAL, 2023, 190
  • [22] On-line aptamer affinity solid-phase extraction capillary electrophoresis-mass spectrometry for the analysis of protein biomarkers in biological fluids and food: A tutorial
    Vergara-Barberan, Maria
    Pont, Laura
    Salim, Hiba
    Gimenez, Estela
    Benavente, Fernando
    ADVANCES IN SAMPLE PREPARATION, 2023, 7
  • [23] Metabolic profiling for the identification of Huntington biomarkers by on-line solid-phase extraction capillary electrophoresis mass spectrometry combined with advanced data analysis tools
    Pont, Laura
    Benavente, Fernando
    Jaumot, Joaquim
    Tauler, Roma
    Alberch, Jordi
    Gines, Silvia
    Barbosa, Jose
    Sanz-Nebot, Victoria
    ELECTROPHORESIS, 2016, 37 (5-6) : 795 - 808
  • [24] On-line solid-phase extraction to enhance sensitivity in peptide biomarker analysis by microseparation techniques coupled to mass spectrometry: Capillary liquid chromatography versus capillary electrophoresis
    El Ouahabi, Oumaima
    Mancera-Arteu, Montserrat
    Pont, Laura
    Gimenez, Estela
    Sanz-Nebot, Victoria
    Benavente, Fernando
    MICROCHEMICAL JOURNAL, 2022, 183
  • [25] Miniaturised on-line solid-phase extraction for enhancement of concentration sensitivity in capillary electrophoresis
    Petersson, M
    Wahlund, KG
    Nilsson, S
    JOURNAL OF CHROMATOGRAPHY A, 1999, 841 (02) : 249 - 261
  • [26] The development of a two-leveled two cross interface for on-line coupling solid-phase extraction and capillary electrophoresis-mass spectrometry
    Lee, Wei-Han
    Her, Guor-Rong
    ELECTROPHORESIS, 2009, 30 (10) : 1675 - 1683
  • [27] On-line solid-phase extraction for liquid chromatography-mass spectrometry analysis of pesticides
    Lucci, Paolo
    Nunez, Oscar
    JOURNAL OF SEPARATION SCIENCE, 2014, 37 (20) : 2929 - 2939
  • [28] Accurate determination of the milk protein allergen β-lactoglobulin by on-line aptamer affinity solid-phase extraction capillary electrophoresis-mass spectrometry
    Vergara-Barberan, Maria
    Simo-Alfonso, Ernesto Francisco
    Herrero-Martinez, Jose Manuel
    Benavente, Fernando
    TALANTA, 2023, 259
  • [29] Evaluation of on-line solid phase extraction-capillary electrophoresis-electrospray-mass spectrometry for the analysis of neuropeptides in human plasma
    Hernandez, Elena
    Benavente, Fernando
    Sanz-Nebot, Victoria
    Barbosa, Jose
    ELECTROPHORESIS, 2008, 29 (16) : 3366 - 3376
  • [30] Analyses of gibberellins by capillary electrophoresis-mass spectrometry combined with solid-phase extraction
    Ge, Liya
    Peh, Clare Yunn Chyn
    Yong, Jean Wan Hong
    Tan, Swee Ngin
    Hua, Lin
    Ong, Eng Shi
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1159 (1-2) : 242 - 249