Analysis of serum transthyretin by on-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry using magnetic beads

被引:21
|
作者
Pero-Gascon, Roger [1 ]
Pont, Laura [1 ]
Benavente, Fernando [1 ]
Barbosa, Jose [1 ]
Sanz-Nebot, Victoria [1 ]
机构
[1] Univ Barcelona, Dept Analyt Chem, E-08028 Barcelona, Spain
关键词
Capillary electrophoresis; Magnetic beads; Mass spectrometry; On-line immunopurification; Transthyretin; CEREBROSPINAL-FLUID; OPIOID-PEPTIDES; MICROCHIP ELECTROPHORESIS; HUMAN PLASMA; PROTEIN; BIOMOLECULES; PREALBUMIN; BIOMARKERS; ISOFORMS; SORBENT;
D O I
10.1002/elps.201500495
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this paper, an on-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry (IA-SPE-CE-MS) method using magnetic beads (MBs) is described for the analysis of serum transthyretin (TTR), which is a protein related to different types of amyloidosis. First, purification of TTR from serum was investigated by off-line immunoprecipitation and CE-MS. The suitability of three Protein A (ProA) MBs (Protein A Ultrarapid Agarose (TM) ( UAPA), Dynabeads (R) Protein A (DyPA) and SiMAG-Protein A (SiPA) and AffiAmino Ultrarapid Agarose (TM) (UAAF) MBs to prepare an IA sorbent with a polyclonal antibody (Ab) against TTR, was studied. In all cases, results were repeatable and it was possible the identification and the quantitation of the relative abundance of the six most abundant TTR proteoforms. Although recoveries were the best with UAPA MBs, UAAF MBs were preferred for on-line immunopurification because Ab was not eluted from the MBs. Under the optimized conditions with standards in IA-SPE-CEMS, microcartridge lifetime (> 20 analyses/day) and repeatability (2.9 and 4.3% RSD for migration times and peak areas) were good, the method was linear between 5 and 25 mu g/mL and LOD was around 1 mu g/mL (25 times lower than by CE-MS, approximate to 25 mu g/mL). A simple off-line sample pretreatment based on precipitation of the most abundant proteins with 5% (v/v) of phenol was necessary to clean-up serum samples. The potential of the on-line method to screen for familial amyloidotic polyneuropathy type I (FAP-I), which is the most common hereditary systemic amyloidosis, was demonstrated analysing serum samples from healthy controls and FAP-I patients.
引用
收藏
页码:1220 / 1231
页数:12
相关论文
共 50 条
  • [1] On-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry using Fab' antibody fragments for the analysis of serum transthyretin
    Pont, Laura
    Benavente, Fernando
    Barbosa, Jose
    Sanz-Nebot, Victoria
    TALANTA, 2017, 170 : 224 - 232
  • [2] On-line immunoaffinity solid-phase extraction capillary electrophoresis mass spectrometry for the analysis of large biomolecules: A preliminary report
    Medina-Casanellas, Silvia
    Benavente, Fernando
    Gimenez, Estela
    Barbosa, Jose
    Sanz-Nebot, Victoria
    ELECTROPHORESIS, 2014, 35 (15) : 2130 - 2136
  • [3] Preparation and evaluation of an immunoaffinity sorbent for the analysis of opioid peptides by on-line immunoaffinity solid-phase extraction capillary electrophoresis-mass spectrometry
    Medina-Casanellas, Silvia
    Benavente, Fernando
    Barbosa, Jose
    Sanz-Nebot, Victoria
    ANALYTICA CHIMICA ACTA, 2012, 717 : 134 - 142
  • [4] Preparation and evaluation of an immunoaffinity sorbent with Fab' antibody fragments for the analysis of opioid peptides by on-line immunoaffinity solid-phase extraction capillary electrophoresis-mass spectrometry
    Medina-Casanellas, Silvia
    Benavente, Fernando
    Barbosa, Jose
    Sanz-Nebot, Victoria
    ANALYTICA CHIMICA ACTA, 2013, 789 : 91 - 99
  • [5] On-line Aptamer Affinity Solid-Phase Extraction Capillary Electrophoresis-Mass Spectrometry for the Analysis of Blood α-Synuclein
    Pero-Gascon, Roger
    Benavente, Fernando
    Minic, Zoran
    Berezovski, Maxim V.
    Sanz-Nebot, Victoria
    ANALYTICAL CHEMISTRY, 2020, 92 (01) : 1525 - 1533
  • [6] Evaluation of on-line solid-phase extraction capillary electrophoresis - mass spectrometry with a nanoliter valve for the analysis of peptide biomarkers
    Pero-Gascon, Roger
    Benavente, Fernando
    Neusuess, Christian
    Sanz-Nebot, Victoria
    ANALYTICA CHIMICA ACTA, 2020, 1140 (1140) : 1 - 9
  • [7] Identification of proteins by capillary electrophoresis tandem mass spectrometry - Evaluation of an on-line solid-phase extraction device
    Figeys, D
    Ducret, A
    Aebersold, R
    JOURNAL OF CHROMATOGRAPHY A, 1997, 763 (1-2) : 295 - 306
  • [8] Analysis of glycopeptide biomarkers by on-line TiO2 solid-phase extraction capillary electrophoresis-mass spectrometry
    Mancera-Arteu, Montserrat
    Lleshi, Nejsi
    Sanz-Nebot, Victoria
    Gimenez, Estela
    Benavente, Fernando
    TALANTA, 2020, 209
  • [9] Improved solid-phase microextraction device for use in on-line immunoaffinity capillary electrophoresis
    Guzman, NA
    ELECTROPHORESIS, 2003, 24 (21) : 3718 - 3727
  • [10] On-line dialysis solid-phase extraction coupled to capillary electrophoresis
    Veraart, JR
    van Hekezen, J
    Groot, MCE
    Gooijer, C
    Lingeman, H
    Velthorst, NH
    Brinkman, UAT
    ELECTROPHORESIS, 1998, 19 (16-17) : 2944 - 2949