Double-phase parathyroid technetium-99m-MIBI scintigraphy to identify functional autonomy in secondary hyperparathyroidism

被引:0
|
作者
Piga, M
Bolasco, P
Satta, L
Altieri, P
Loi, G
Nicolosi, A
Tarquini, A
Mariotti, S
机构
[1] UNIV CAGLIARI,DEPT NUCL MED,CAGLIARI,ITALY
[2] UNIV CAGLIARI,DEPT CLIN SURG,CAGLIARI,ITALY
[3] UNIV CAGLIARI,DEPT ENDOCRINOL,CAGLIARI,ITALY
[4] S MICHELE HOSP,DEPT DIALYSIS,CAGLIARI,ITALY
关键词
uremic secondary hyperparathyroidism; technetium-99m-MIBI; parathyroid hyperfunction; parathyroid hyperplasia;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Double-phase Tc-99m-methoxyisobutylisonitrile (MIBI) parathyroid scintigraphy has been proposed to detect hyperplastic parathyroid tissue, but the clinical usefulness of this technique in secondary hyperparathyroidism is still debated. Methods: Technetium-99m-MIBI parathyroid scintigraphy associated with parathyroid echography and [Tc-99m]pertechnetate thyroid scans were performed on 38 patients with chronic renal failure (CRF) and secondary hyperparathyroidism. In all patients, serum calcium, phosphorus, FT3, FT4, TSH, calcitonin and intact PTH (IPTH) were determined. Nine patients eventually underwent neck exploration and 28 parathyroid glands were removed. Results: Thyroid diseases were excluded in all patients. Echography revealed parathyroid enlargement in 22/38 (58%) patients, while MIBI scintigraphy was positive in 28/38 (74%), including 5-ectopic glands. Mean serum IPTH concentration was significantly higher in MIBI-positive patients compared to MIBI-negative patients. Mean echographic and surgical parathyroid size were significantly higher in MIBI-positive glands compared to MIBI-negative glands, but several discrepancies were observed in single patients. A significant positive correlation between serum IPTH and gland size was observed when MIBI-positive, but not MIBI-negative, parathyroids were considered. A paradoxical positive correlation between serum calcium and IPTH concentrations was found in MIBI-positive patients. Conclusion: Double-phase Tc-99m-MIBI scintigraphy is positive in the majority of patients with uremic hyperparathyroidism. Comparison of scintigraphic data with morphological and functional data strongly suggests that (TC)-T-99m-MIBI scans do not reveal simple parathyroid enlargement but rather, identify the presence of hyperfunctioning (autonomous) parathyroid tissue suggestive of tertiary hyperparathyroidism.
引用
收藏
页码:565 / 569
页数:5
相关论文
共 50 条
  • [41] Hurthle cell tumor and technetium-99m-SESTAMIBI scintigraphy (single injection double-phase study).
    Vattimo, A
    Volterrani, D
    Bertelli, P
    Burroni, L
    Vella, A
    [J]. RADIOACTIVE ISOTOPES IN CLINICAL MEDICINE AND RESEARCH, 1997, : 83 - 88
  • [42] DETECTION AND LOCALIZATION OF PARATHYROID ADENOMAS IN PATIENTS WITH HYPERPARATHYROIDISM USING A SINGLE RADIONUCLIDE IMAGING PROCEDURE WITH TECHNETIUM-99M-SESTAMIBI (DOUBLE-PHASE STUDY)
    TAILLEFER, R
    BOUCHER, Y
    POTVIN, C
    LAMBERT, R
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1992, 33 (10) : 1801 - 1807
  • [43] Localization of parathyroid enlargement:: dual-tracer subtraction technique and double-phase 99mTc-MIBI scintigraphy are complementary procedures
    Koranda, Pavel
    Halenka, Milan
    Myslivecek, Miroslav
    Kaminek, Milan
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (01) : 219 - 220
  • [44] Localization of parathyroid enlargement: dual-tracer subtraction technique and double-phase 99mTc-MIBI scintigraphy are complementary procedures
    Pavel Koranda
    Milan Halenka
    Miroslav Myslivecek
    Milan Kaminek
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2008, 35 : 219 - 220
  • [45] Double-phase 99mTc-sestamibi scintigraphy in the localization of abnormal parathyroid glands
    Bernà, L
    Piera, J
    Rodríguez-Espinosa, J
    Caixàs, A
    Puig-Domingo, M
    Farrerons, J
    Galofré, M
    Rousaud, F
    Matías-Guiu, X
    Estorch, M
    Carrió, I
    [J]. MEDICINA CLINICA, 1999, 112 (06): : 201 - 205
  • [46] Pinhole Collimator Double-Phase Scintigraphy with 99mTc-SESTAMIBI in Patients wirh Secondary Hyperparathyroidism Treated with Cinacalcet
    Fuster, D.
    Depetris, M.
    Paschoalin, R.
    Torregrosa, J. V.
    Setoain, X.
    Squarcia, M.
    Perissinotti, A.
    Mayoral, M.
    Pons, F.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S481 - S481
  • [47] Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism
    Francesca Pons
    Josep-Vicens Torregrosa
    Sergi Vidal-Sicart
    Lluís Sabater
    David Fuster
    Laureano Fernández-Cruz
    Ramón Herranz
    [J]. European Journal of Nuclear Medicine, 1997, 24 : 1494 - 1498
  • [48] 99mTc-Tetrofosmin or 99mTc-Sestamibi for double-phase parathyroid scintigraphy.
    Fröberg, AC
    Valkema, R
    Bonjer, HJ
    Krenning, EP
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 326P - 326P
  • [49] Preoperative parathyroid gland localization with technetium-99m sestamibi in secondary hyperparathyroidism
    Pons, F
    Torregrosa, JV
    Vidal-Sicart, S
    Sabater, L
    Fuster, D
    Fernández-Cruz, L
    Herranz, R
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1997, 24 (12) : 1494 - 1498
  • [50] IDENTIFICATION OF HURTHLE CELL TUMOR BY SINGLE-INJECTION, DOUBLE-PHASE SCINTIGRAPHY WITH TECHNETIUM-99M-SESTAMIBI
    VATTIMO, A
    BERTELLI, P
    CINTORINO, M
    BURRONI, L
    VOLTERRANI, D
    VELLA, A
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (05) : 778 - 782