The electric field and surface charges far and close to the battery for the transmission line

被引:2
|
作者
Hernandes, J. A. [1 ]
Nogueira, G. T. [1 ]
机构
[1] Univ Fed Juiz de Fora UFJF, Dept Fis, BR-36036000 Juiz De Fora, MG, Brazil
关键词
surface charges; electric field; transmission line; bi-cylinder coordinates; CARRYING STEADY CURRENTS; CONSTANT-CURRENT; CIRCUITS;
D O I
10.1088/0143-0807/37/2/025202
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
We consider two long resistive straight parallel wires carrying opposite constant currents and calculate the potential and electric field everywhere in space and the surface charge densities along the wires. The problem is solved through Laplace's equation in bi-cylinder coordinates, far from the battery. We compare these calculations with previous known results that used different methods. We also calculate the numerical solution for the case in which the battery is present, and show the equipotentials and surface charges close to the battery.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Modeling of an ionized electric field on the building near the UHVDC transmission line
    ZHEN YongZan
    CUI Xiang
    LU TieBing
    Science China Technological Sciences, 2014, (04) : 747 - 753
  • [32] A Numerical Analysis of Electric Field Distribution under EHVAC Transmission Line
    Rajeswari, P.
    Maheswari, R. V.
    Iruthayarajan, M. Willjuice
    2014 IEEE INTERNATIONAL CONFERENCE ON CIRCUIT, POWER AND COMPUTING TECHNOLOGIES (ICCPCT-2014), 2014, : 130 - 135
  • [33] Analysis on control index of total electric field for DC transmission line
    College of Electrical Engineering, Wuhan University, Wuhan 430072, China
    不详
    不详
    Gaodianya Jishu, 2012, 11 (2843-2847):
  • [34] Modeling of an ionized electric field on the building near the UHVDC transmission line
    ZHEN YongZan
    CUI Xiang
    LU TieBing
    Science China(Technological Sciences), 2014, 57 (04) : 747 - 753
  • [35] Modeling of an ionized electric field on the building near the UHVDC transmission line
    Zhen YongZan
    Cui Xiang
    Lu TieBing
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2014, 57 (04) : 747 - 753
  • [36] The Spatial Distribution of Electric Field as a Unifying Idea in Transmission Line Design
    Olsen, Robert G.
    Zhuang, Chijie
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (03) : 919 - 928
  • [37] CALCULATING THE ELECTRIC-FIELD OF A 3 PHASE TRANSMISSION-LINE
    KATS, RA
    PERELMAN, LS
    ELECTRICAL TECHNOLOGY, 1978, (01): : 15 - 25
  • [38] ELECTRIC-FIELD OF A TRANSMISSION-LINE OVER MULTILAYERED MEDIA
    MOGHRAM, IS
    TYLAVSKY, DJ
    PROCEEDINGS OF THE IEEE, 1987, 75 (01) : 170 - 171
  • [39] Modeling of an ionized electric field on the building near the UHVDC transmission line
    YongZan Zhen
    Xiang Cui
    TieBing Lu
    Science China Technological Sciences, 2014, 57 : 747 - 753
  • [40] Surface charges on silicon rubber (SiR) insulator and their effect on potential and electric field distribution
    Mahmoodi, Jamshid
    Mirzaie, Mohammad
    Akmal, Amir Abbas Shayegani