Effects of multiple draft tubes with perforated plates on average gas holdup, volumetric mass transfer coefficient and liquid mixing time in a bubble column

被引:1
|
作者
Kawasaki, Hiroyuki [1 ]
Yamamoto, Tatsurni [1 ]
机构
[1] Toyama Univ, Dept Mat Syst Engn & Life Sci, Toyama 9308555, Japan
关键词
bubble column; draft tube with perforated plate; gas holdup; volumetric mass transfer coefficient; liquid mixing time;
D O I
10.1252/kakoronbunshu.33.208
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experiments were performed to study the effects of multiple draft tubes with perforated plates on average gas holdup, phi, volumetric mass transfer coefficient, k(L)a, and liquid mixing time, t(M), in a bubble column with 5 draft tubes, and a varying number of holes, n, of constant diameter on the perforated plates. phi and k(L)a increased with increasing superficial gas velocity u(Go), and n, respectively. The highest values were obtained for 5 draft tubes with perforated plates having n=323. t(M) decreased with increasing u(Go). For the perforated plates with n = 21, t(M) increased with increasing N at the same u(Go); but with n=323, t(M) was independent of N and became equal to one with no draft tube.
引用
收藏
页码:208 / 210
页数:3
相关论文
共 50 条
  • [31] DETERMINATION OF THE OZONE VOLUMETRIC MASS TRANSFER COEFFICIENT IN BUBBLE COLUMN WITH TWO-FLUID NOZZLE GAS DISTRIBUTOR
    Sevic, Milica Dekovic
    Boskovic-Vragolovic, Nevenka
    Takic, Ljiljana
    Garic-Grulovic, Radmila
    Pejanovic, Srdan
    [J]. HEMIJSKA INDUSTRIJA, 2015, 69 (05) : 553 - 559
  • [32] Bubble column photobioreactor for Chlorella pyrenoidosa cultivation and validating gas hold up and volumetric mass transfer coefficient
    Mubarak, M.
    Shaija, A.
    Prashanth, P.
    [J]. ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2023, 45 (04) : 9779 - 9793
  • [33] Volumetric mass transfer coefficient and gas hold-up in highly viscous liquid in bubble columns
    Tokanai, H
    Harada, E
    Kuriyama, M
    [J]. KAGAKU KOGAKU RONBUNSHU, 2001, 27 (06) : 792 - 798
  • [34] Method for Determining the Ozone Mass Transfer Coefficient between the Gas and Liquid Phases in a Bubble Column Reactor
    Levanov, A. V.
    Lapina, A. V.
    Isaikina, O. Ya.
    [J]. RUSSIAN JOURNAL OF PHYSICAL CHEMISTRY A, 2024, 98 (07) : 1461 - 1465
  • [35] Effects of Bubble Interactions in Circulating Liquid Flow on Liquid Phase Mass Transfer Coefficient in an External Loop Airlift Bubble Column
    Yoshimoto, Makoto
    Furumoto, Keiji
    Nakao, Katsumi
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2012, 45 (09) : 661 - 665
  • [36] Effects of liquid property on gas holdup and mass transfer in co-current downflow contacting column
    Akosman, C
    Orhan, R
    Dursun, G
    [J]. CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2004, 43 (04) : 503 - 509
  • [37] VOLUMETRIC GAS-LIQUID MASS-TRANSFER COEFFICIENTS IN A RECTANGULAR BUBBLE COLUMN WITH A RUBBER AERATION PAD
    MEDIC, L
    CEHOVIN, A
    KOLOINI, T
    PAVKO, A
    [J]. CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1989, 41 (03): : B51 - B54
  • [38] GAS-LIQUID INTERFACIAL AREA AND LIQUID-SIDE MASS-TRANSFER COEFFICIENT IN A SLURRY BUBBLE COLUMN
    SADA, E
    KUMAZAWA, H
    LEE, CH
    NARUKAWA, H
    [J]. INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1987, 26 (01) : 112 - 116
  • [39] DETERMINATION OF LIQUID-SIDE AND GAS-SIDE VOLUMETRIC MASS-TRANSFER COEFFICIENTS IN A BUBBLE COLUMN
    CHO, JS
    WAKAO, N
    [J]. JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1988, 21 (06) : 576 - 581
  • [40] Gas holdup, liquid circulating velocity and mass transfer properties in a mini-scale external loop airlift bubble column
    Wang, S
    Arimatsu, Y
    Koumatsu, K
    Furumoto, K
    Yoshimoto, M
    Fukunaga, K
    Nakao, K
    [J]. CHEMICAL ENGINEERING SCIENCE, 2003, 58 (15) : 3353 - 3360