Dose painting with intensity modulated proton therapy and intensity modulated x-ray therapy: A comparison

被引:5
|
作者
Flynn, R.
Barbee, D.
Bowen, S.
McCall, K.
Bentzen, S.
Mackie, T.
Jeraj, R.
机构
[1] Univ Wisconsin, Madison, WI 53706 USA
[2] TomoTherapy Inc, Madison, WI USA
关键词
D O I
10.1118/1.2761242
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare intensity modulated proton therapy (IMPT) versus intensity modulated x‐ray therapy (IMXT) for the delivery of nonuniform dose prescriptions based on hypoxia‐imaging, so‐called dose painting. Materials and Methods: IMXT delivered with helical tomotherapy (HT) was compared to IMPT delivered with spot scanning (SS) and distal gradient tracking (DGT). The novel DGT method places beam spots where dose prescription gradients occur along the pencil beam axis. Fundamental dosimetric properties of each modality were assessed by creating optimized plans for 144 variations of a cylindrical phantom with six boost regions embedded inside a base tumor region. Clinical cases with biologically conformal dose prescriptions based on PET with the [formula omitted]‐ATSM hypoxia imaging radiopharmaceutical were planned. The effects on the nonuniform dose distribution of delivering IMPT on a 180° arc versus equi‐spaced beams spread over 360° were investigated. Results: Phantom studies showed that nonuniform dose plan quality for tomotherapy, SS, and DGT, was similar, but DGT plans were most sensitive to phantom size and boost region proximity. IMPT reduced normal tissue integral dose by a mean factor of around two relative to IMXT. Clinical dose deviations from the prescription were comparable for all modalities, but arc IMPT deliveries markedly reduced normal tissue dose and improved critical structure sparing without compromising the dose distribution in the tumor. Conclusions: In the target volume, IMXT and IMPT deliver comparable nonuniform dose distributions. IMPT offers improved integral normal tissue dose and sparing of critical structures over IMXT, as was the case for uniform dose deliveries. DGT reduces required beam spots by a factor of about three relative to SS. IMPT dose painting will require similar management of intrafractional patient motion as for IMXT, with the additional consideration of proton spot placement uncertainty. TR Mackie has a conflict of interest due to financial interest in TomoTherapy, Inc. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2522 / 2523
页数:2
相关论文
共 50 条
  • [31] Intensity modulated proton therapy: A clinical example
    Lomax, AJ
    Boehringer, T
    Coray, A
    Egger, E
    Goitein, G
    Grossmann, M
    Juelke, P
    Lin, S
    Pedroni, E
    Rohrer, B
    Roser, W
    Rossi, B
    Siegenthaler, B
    Stadelmann, O
    Stauble, H
    Vetter, C
    Wisser, L
    MEDICAL PHYSICS, 2001, 28 (03) : 317 - 324
  • [32] The Status of Intensity Modulated Proton and Ion Therapy
    Dong, L.
    Zhu, X.
    Unkelbach, J.
    Schulte, R.
    MEDICAL PHYSICS, 2014, 41 (06) : 536 - 536
  • [33] Delivery confirmation of bolus electron conformal therapy combined with intensity modulated x-ray therapy
    Kavanaugh, James A.
    Hogstrom, Kenneth R.
    Chu, Connel
    Carver, Robert A.
    Fontenot, Jonas P.
    Henkelmann, Gregory
    MEDICAL PHYSICS, 2013, 40 (02)
  • [34] Robust optimization of intensity modulated proton therapy
    Liu, Wei
    Zhang, Xiaodong
    Li, Yupeng
    Mohan, Radhe
    MEDICAL PHYSICS, 2012, 39 (02) : 1079 - 1091
  • [35] TOOLS FOR DEVELOPING INTENSITY MODULATED PROTON THERAPY
    Choe, M.
    Selchau, A.
    Gonzales, D.
    Giacometti, V
    Schulte, R.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2014, 62 (01) : 218 - 218
  • [36] Prioritized optimization in intensity modulated proton therapy
    Falkinger, Marita
    Schell, Stefan
    Mueller, Johannes
    Wilkens, Jan J.
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2012, 22 (01): : 21 - 28
  • [37] Application of Fast Inverse Dose Optimization for Intensity Modulated Proton Therapy
    MacFarlane, M.
    Mossahebi, S.
    Chen, J.
    Lamichhane, N.
    Guerrero, M.
    MEDICAL PHYSICS, 2020, 47 (06) : E700 - E700
  • [38] Dosimetric Comparison of Intensity Modulated Radiation Therapy (IMRT), 3D Conformal Proton Therapy and Intensity Modulated Proton Therapy (IMPT) for Metastatic Brain Cancer
    Sullivan, M.
    Ahmad, S.
    Jin, H.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [39] Proton radiotherapy for ependymoma: Initial clinical outcomes and dose comparisons for intensity modulated radiation with photons, proton radiation, and intensity modulated proton therapy
    Yock, T. I.
    MacDonald, S. M.
    Safai, S.
    Wolfgang, J. A.
    Fullerton, B.
    Trofimov, A.
    Bortfeld, T. R.
    Tarbell, N. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S575 - S576
  • [40] Intensity Modulated Proton Therapy Is Dosimetrically Superior to Intensity Modulated Radiation Therapy for Head-and-Neck Cancers
    Yeh, B. K.
    Zhu, X. R.
    Palmer, M. B.
    Amin, M. V.
    Georges, R. H.
    Nuanjing, J.
    Garcia, J. A.
    Frank, S. J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S840 - S840