Enhanced hydrophobically modified polyacrylamide gel for lost circulation treatment in high temperature drilling

被引:35
|
作者
Xie, Binqiang [1 ,2 ]
Ma, Jiang [3 ]
Wang, Yun [3 ]
Tchameni, Alain P. [1 ]
Luo, Mingwang [1 ]
Wen, Jiantai [1 ]
机构
[1] Yangtze Univ, Natl Engn Lab Petr Drilling Engn, Lost Circulat Control Lab, Wuhan 430100, Peoples R China
[2] Oil & Gas Field Appl Chem Key Lab Sichuan Prov, Chengdu 610500, Peoples R China
[3] CNPC XIBU Drilling Engn Co Ltd, Urumqi 834000, Xinjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Polyacrylamide gels; Cross-linking; Gelation; Hydrophobically modified polyacrylamide; Lost circulation; YIELD-STRESS; OIL; SYSTEM; PERFORMANCE; BENTONITE; WELLS;
D O I
10.1016/j.molliq.2020.115155
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Cross-linked polymer gels have attracted a strong interest for lost circulation treatment in drilling operation. However, the application of gels in high temperature loss zone was still limited due to the problems of short gelation time, weak strength, poor thermal stability, etc. In this paper, a novel cross-linked modified polyacrylamide gel (HMP-Gel), which consisted of a hydrophobically modified polyacrylamide (HMP) and crosslinker polyethyleneimine (PEI), was designed and developed. The novel HMP was synthesized to form and strengthen the gel structure due to the crosslinkable amide groups and associable hydrophobic moieties, and PEI was used to extend gelation time at high temperature. In detail, the HMP of acrylamide (AM), octadecyl acrylate (OA), and 2-acrylarn ide-2-methylpropanesulfonic acid (AMPS) was prepared using micellar copolymerization under the best conditions. The molecular structure of HMP was characterized using FT-IR. gel permeation chromatography and environmental scanning electron microscope (ESEM). In gelation process, effects of PEI concentration. HMP concentration, temperature and salinity on gel performance (plugging efficiency and gelation time) were systematically investigated. Plugging performance of HMP-Gel was studied using both the HTHP carbonate bed filtration loss test and HTHP crack plugging test. Rheological property of HMP-Gel was studied to access the elastic properties and gel strength. Results of various factors on gel performance indicated that HMP-Gel showed the good plugging efficiency for carbonate bed and controllable gelation time in the temperature range of 100-150 degrees C. Results from plugging tests indicated that the HMP-Gel had better sealing ability than HPAM-gel for both the high permeable carbonate bed and 1-3 mm cracks loss zone. And the breaking pressure of HMP-Gel could reach 1000 psi and 600 psi for carbonate bed and 3 mm slot, respectively. Additionally, HMP-Gel also showed high elasticity, gel strength, and excellent thermal stability at 140 degrees C. Finally, the micro-morphology of gel was further analyzed through ESEM. A new strategy of using hydrophobically modified polyacrylamide to strengthen the gel structure was proposed, and extensive laboratory tests suggested that HMP-Gel could be considered as an efficient plugging material and showed great potential in applications for lost circulation in high-temperature well. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Hydrophobically modified polyacrylamide block copolymers for fast, high-resolution DNA sequencing in microfluidic chips
    Forster, Ryan E.
    Chiesl, Thomas N.
    Fredlake, Christopher P.
    White, Corin V.
    Barron, Annelise E.
    ELECTROPHORESIS, 2008, 29 (23) : 4669 - 4676
  • [22] Experimental study on an oil-based polymer gel for lost circulation control in high-temperature fractured formation
    Qiu, Jiaxian
    Bai, Yingrui
    Sun, Jinsheng
    Dai, Liyao
    Lei, Shaofei
    Liu, Fan
    JOURNAL OF APPLIED POLYMER SCIENCE, 2022, 139 (10)
  • [23] Low-Temperature Recrosslinkable Preformed Particle Gel as a Material for Lost Circulation Control
    Ahdaya, Mohamed
    Al Brahim, Ali
    Bai, Baojun
    Schuman, Thomas
    SPE JOURNAL, 2022, 27 (05): : 2541 - 2551
  • [24] Plugging performance and mechanism of an oil-absorbing gel for lost circulation control while drilling in fractured formations
    Bai, Ying-Rui
    Dai, Li-Yao
    Sun, Jin-Sheng
    Jiang, Guan-Cheng
    Lv, Kai-He
    Cheng, Rong-Chao
    Shang, Xiao-Sen
    PETROLEUM SCIENCE, 2022, 19 (06) : 2941 - 2958
  • [25] Plugging performance and mechanism of an oil-absorbing gel for lost circulation control while drilling in fractured formations
    Ying-Rui Bai
    Li-Yao Dai
    Jin-Sheng Sun
    Guan-Cheng Jiang
    Kai-He Lv
    Rong-Chao Cheng
    Xiao-Sen Shang
    Petroleum Science, 2022, 19 (06) : 2941 - 2958
  • [26] High-temperature sodium dodecyl sulfate polyacrylamide gel electrophoresis
    Haeberle, JR
    BIOTECHNIQUES, 1997, 23 (04) : 638 - 640
  • [27] Self-assembly networks of wormlike micelles and hydrophobically modified polyacrylamide with high performance in fracturing fluid application
    Fu Chen
    Yue Wu
    Meng Wang
    Renlan Zha
    Colloid and Polymer Science, 2015, 293 : 687 - 697
  • [28] Self-assembly networks of wormlike micelles and hydrophobically modified polyacrylamide with high performance in fracturing fluid application
    Chen, Fu
    Wu, Yue
    Wang, Meng
    Zha, Renlan
    COLLOID AND POLYMER SCIENCE, 2015, 293 (03) : 687 - 697
  • [29] NEW CEMENT HANDLES BOTH HIGH-TEMPERATURE, LOST CIRCULATION
    SUTTON, DL
    ROLL, DL
    DELEON, R
    WORLD OIL, 1983, 196 (05) : 101 - 104
  • [30] Hydrophobically modified low molecular weight polymers as high temperature resistant shale inhibitor
    Wang, Zonglun
    Liu, Jingping
    Lv, Kaihe
    Shao, Zihua
    Zhang, Xianfa
    Xu, Zhe
    Zhang, Fan
    Dong, Xiaodong
    Sun, Jinsheng
    JOURNAL OF MOLECULAR LIQUIDS, 2023, 382