Comparison of a Modified Transient Plane Source and Transient Line Source Techniques for Measuring the Thermal Conductivity of Two Sands

被引:0
|
作者
Yao, Jun [1 ]
Likos, William J. [2 ]
机构
[1] Univ Wisconsin Madison, Dept Civil & Environm Engn, Madison, WI 53706 USA
[2] Univ Wisconsin Madison, Dept Civil & Environm Engn, Geol Engn Program, Madison, WI 53706 USA
关键词
TEMPERATURE;
D O I
暂无
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Experiments were conducted to compare two laboratory techniques for measuring thermal conductivity of unsaturated soils: ( 1) a modified transient plane source (MTPS) method for non-destructive measurements using a planar, interfacial heat reflectance sensor; and (2) a transient line source (TLS) method utilizing a single-probe heat source. Thermal conductivity and thermal conductivity dry out curves (TCDCs) were measured for two sands, including a poorly graded sand, and a well-graded sand with silt. The MTPS sensor resulted in larger thermal conductivity values than the TLS sensor for pore water saturations greater than 50%. At low pore water saturation, the MTPS sensor potentially underestimates thermal conductivity due to poor sensor-soil contact potentially resulting from the absence of water bridges between the sensor and soil surface.
引用
收藏
页码:669 / 677
页数:9
相关论文
共 50 条
  • [41] Contribution to the Transient Plane Source Method for Measuring Thermophysical Properties of Solids
    Svetozár Malinarič
    International Journal of Thermophysics, 2013, 34 : 1953 - 1961
  • [42] Contribution to the Transient Plane Source Method for Measuring Thermophysical Properties of Solids
    Malinaric, Svetozar
    INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2013, 34 (10) : 1953 - 1961
  • [43] Determination of the Thermal Conductivity Tensor of Thermally Orthotropic Materials with Transient Line Heat Source Method
    Chen, Bao
    Huang, Yiyi
    Zhang, Kang
    Cui, Yujun
    JOURNAL OF TESTING AND EVALUATION, 2018, 46 (05) : 2033 - 2044
  • [44] Applicability of the transient plane source method to measure the thermal conductivity of low-density polyethylene foams
    Almanza, O
    Rodríguez-Pérez, MA
    De Saja, JA
    JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2004, 42 (07) : 1226 - 1234
  • [45] Analysis of radiation effect on thermal conductivity measurement of semitransparent materials based on transient plane source method
    Wang, Shuai
    Ai, Qing
    Zou, Tian-qi
    Sun, Chuang
    Xie, Ming
    APPLIED THERMAL ENGINEERING, 2020, 177
  • [46] A single-sided method based on transient plane source technique for thermal conductivity measurement of liquids
    Ai, Qing
    Hu, Zhen-Wen
    Wu, Lin-Lin
    Sun, Feng-Xian
    Xie, Ming
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 109 : 1181 - 1190
  • [47] Thermal conductivity of AZ91 magnesium integral foams measured by the Transient Plane Source method
    Solorzano, E.
    Hirschmann, M.
    Rodriguez-Perez, M. A.
    Korner, C.
    de Saja, J. A.
    MATERIALS LETTERS, 2008, 62 (24) : 3960 - 3962
  • [48] Transient thermal conductivity measurements: comparison of destructive and nondestructive techniques
    Mathis, N
    HIGH TEMPERATURES-HIGH PRESSURES, 2000, 32 (03) : 321 - 327
  • [49] Optimization of cooling time for measuring thermal properties of electronic materials using the transient plane source technique
    Dixon, C
    Canney, B
    Strong, MR
    2001 HD INTERNATIONAL CONFERENCE ON HIGH-DENSITY INTERCONNECT AND SYSTEMS PACKAGING, PROCEEDINGS, 2001, 4428 : 262 - 267
  • [50] Simultaneous determination of thermal conductivity and thermal diffusivity of food and agricultural materials using a transient plane-source method
    Huang, Lihan
    Liu, Lin-Shu
    JOURNAL OF FOOD ENGINEERING, 2009, 95 (01) : 179 - 185