Replacement of the aortic valve and ascending aorta with an extended root stentless xenograft

被引:5
|
作者
Hemmer, WB [1 ]
Botha, CA [1 ]
Böhm, JO [1 ]
Herrmann, T [1 ]
Starck, C [1 ]
Rein, JG [1 ]
机构
[1] Sana Herzchirurg Klin, Dept Cardiac Surg, D-70174 Stuttgart, Germany
来源
ANNALS OF THORACIC SURGERY | 2004年 / 78卷 / 06期
关键词
35;
D O I
10.1016/j.athoracsur.2003.09.083
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose. We present an early series to determine the technical feasibility of simultaneous aortic valve and complete ascending aortic replacement using a longer stentless aortic xenograft, harvested with an extended root. Description. The stentless xenograft valved conduits commercially available are too short for complete ascending aorta replacement, and usually a prosthetic tube graft is required distally. Evaluation. To avoid this extra prosthetic conduit distally a number of stentless aortic xenografts with extended conduit were obtained from a supplier (Medtronic Inc). They were inserted in 6 elderly patients (67.8 +/- 7.1 years) who all required aortic valve and ascending aorta replacements owing to pathologic dilation. Conclusions. In all cases an extra prosthetic conduit was avoided, and the length of the available biological conduit comfortably allowed total ascending aortic replacement without tension. The advantages therefore were one less suture line, cost saving regarding the prosthetic conduit, shorter cross-clamping time, and possibly shorter time spent on hemostasis. (C) 2004 by The Society of Thoracic Surgeons.
引用
收藏
页码:2150 / 2153
页数:4
相关论文
共 50 条
  • [41] Multicenter study of stentless valve replacement in the small aortic root
    Hvass, U
    Palatianos, GM
    Frassani, R
    Puricelli, C
    O'Brien, M
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 117 (02): : 267 - 271
  • [42] Stentless Aortic Valve Replacement
    Ennker, J.
    Ennker, I. C.
    ZEITSCHRIFT FUR HERZ THORAX UND GEFASSCHIRURGIE, 2013, 27 (03): : 166 - 170
  • [43] Stentless aortic valve replacement
    Westaby, S
    CARDIO-AORTIC AND AORTIC SURGERY, 2001, 7 : 21 - 23
  • [44] Ascending Aortic Replacement and Sutureless Valve in a Failed Stentless Aortic Prosthesis: A Bailout Option
    Marzouk, Mohamed
    Shanmugam, Ganesh
    Kalavrouziotis, Dimitri
    Mohammadi, Siamak
    ANNALS OF THORACIC SURGERY, 2016, 102 (06): : E507 - E509
  • [45] Replacement of calcified ascending aorta in patients undergoing aortic valve replacement
    Chang, Hyoung Woo
    Jeong, Dong Seop
    Cho, Yang Hyun
    Sung, Kiick
    Kim, Wook-Sung
    Lee, Young Tak
    Park, Pyo Won
    JOURNAL OF THORACIC DISEASE, 2017, 9 (11) : 4424 - 4433
  • [46] "Completion Bentall": replacement of the root and ascending aorta in a patient already wearing an aortic valve prosthesis
    Torre, Mario
    Vassallo, Maria Giovanna
    Longobardi, Antonio
    Ferrara, David
    Scaffa, Raffaele
    Spagnuolo, Mattia
    Bottigliero, Matteo
    Coscioni, Enrico
    GIORNALE ITALIANO DI CARDIOLOGIA, 2021, 22 (10) : 851 - 853
  • [47] Reversed Root for Entirely Biological Aortic Valve and Ascending Aorta Replacement in a Patient with Endocarditis and Mediastinitis
    Albes, J. M.
    Claus, T.
    THORACIC AND CARDIOVASCULAR SURGEON, 2011, 59 (04): : 247 - U74
  • [48] Survival after aortic root replacement with a stentless xenograft is determined by patient characteristics
    Dagnegard, Hanna H.
    Bekke, Kirstine
    Kolseth, Solveig M.
    Glaser, Natalie
    Wallen, Christoffer
    El-Hamamsy, Ismail
    Vidisson, Kristjan O.
    Lie, Asbjorn S.
    Valentin, Jan B.
    Sartipy, Ulrik
    Haaverstad, Rune
    Vanky, Farkas
    Lefebvre, Laurence
    Gudbjartsson, Tomas
    Johnsen, Soren P.
    Sondergaard, Lars
    Thyregod, Gustav H.
    Lund, Jens T.
    Ihlemann, Nikolaj
    Smerup, Morten H.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2022, 164 (06): : 1712 - +
  • [49] A SAFER TECHNIQUE FOR REPLACEMENT OF ENTIRE ASCENDING AORTA AND AORTIC VALVE
    EDWARDS, WS
    KERR, AR
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1970, 59 (06): : 837 - &
  • [50] DISSECTION OF THE ASCENDING AORTA AFTER AORTIC-VALVE REPLACEMENT
    BACHET, J
    MESNILDREY, P
    GOUDOT, B
    TAWIL, N
    DUBOIS, C
    BRODATY, D
    SCHLUMBERGER, S
    GUILMET, D
    PRESSE MEDICALE, 1984, 13 (37): : 2253 - 2256