Compressive Strength Testing of Hybrid Concrete-Filled Fiber-Reinforced Plastic Tubes Confined by Filament Winding

被引:11
|
作者
Kang, In-Kyu [1 ]
Kim, Sun-Hee [2 ]
机构
[1] VNIEL CONSULTANT CO Ltd, Management Support Div, 909 Daeryung Technotown 12th,14, Seoul 08592, South Korea
[2] Gachon Univ, Dept Architectural Engn, 1342 Seongnamdaero, Gyeonggi Do 13120, Seongnam Si, South Korea
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 07期
关键词
compressive strength; hybrid-CFFT; FEA; mechanical properties; FRP;
D O I
10.3390/app11072900
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this study, an experiment on compressive strength of the hybrid concrete-filled fiber-reinforced polymer (FRP) tube (CFFT) confined by filament winding was conducted to improve the longitudinal strength while considering the thickness of filament winding as a variable. A maximum error of 17% was observed when the results of performing the finite element analysis (FEA) by applying the mechanical properties of the fiber-reinforced polymer (FRP) materials suggested in previous studies were compared to those of the compressive strength experiment on the hybrid-CFFT. Moreover, a maximum error of 15% was exhibited when the results derived from the strength equation proposed by analyzing the compressive strength experiment were compared. Furthermore, the compressive strength of the hybrid-CFFT increased by up to 14% when the longitudinal compressive strength of the pre-tensioned spun high strength concrete (PHC) pile and concrete-filled tube (CFT) were compared.
引用
收藏
页数:23
相关论文
共 50 条
  • [31] Study on Compressive Strength of Fiber Reinforced Polymer Confined Concrete
    Zhang Li-wen
    Zhang Jun-ping
    Sun Zuo
    ECOLOGICAL ENVIRONMENT AND TECHNOLOGY OF CONCRETE, 2011, 477 : 443 - +
  • [32] Seismic behavior of high-strength concrete columns confined by fiber-reinforced polymer tubes
    Ozbakkaloglu, Togay
    Saatcioglu, Murat
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2006, 10 (06) : 538 - 549
  • [33] Post-cracking behavior of hybrid fiber-reinforced concrete-filled steel tube beams
    Guler, Soner
    Yavuz, Demet
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 205 : 285 - 305
  • [34] The effect of fiber winding angles on the bending strength of fiber-reinforced plastic rods
    Park, Hoy Yul
    Na, Moon Kyong
    Ahn, Myeong Sang
    Yoon, Seog Young
    Park, Seong Soo
    MECHANICAL BEHAVIOR OF MATERIALS X, PTS 1AND 2, 2007, 345-346 : 661 - +
  • [35] Research advances in fiber-reinforced concrete-filled steel tube columns
    Liu, Zhenzhen
    Ma, Xiaoxia
    Li, Na
    Chen, Juan
    Lu, Yiyan
    STRUCTURAL DESIGN OF TALL AND SPECIAL BUILDINGS, 2024, 33 (15):
  • [36] Strengthen concrete-filled steel tubular column with fiber-reinforced polymer
    Zheng, Hong
    Fan, Jing
    STRUCTURAL CONDITION ASSESSMENT, MONITORING AND IMPROVEMENT, VOLS 1 AND 2, 2007, : 1140 - 1145
  • [37] Peak Strength Expression for Concrete Confined with Fiber-Reinforced Polymer
    Singh, Sonal
    Patra, Nihar Ranjan
    ASCE-ASME JOURNAL OF RISK AND UNCERTAINTY IN ENGINEERING SYSTEMS PART A-CIVIL ENGINEERING, 2018, 4 (03):
  • [38] Compressive Behavior of Concrete-Filled Filament-Wound FRP Tubes with Local Tube Damage
    Lin, Guan
    Xiang, Yu
    JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2023, 27 (02)
  • [39] Hysteresis performance of steel fiber-reinforced high-strength concrete-filled steel tube columns
    Huang, Yue
    Zhao, Pengtuan
    Lu, Yiyan
    Liu, Zhenzhen
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 219
  • [40] Experimental and analytical modeling of concrete-filled fiber-reinforced polymer tubes subjected to combined bending and axial loads
    Fam, A
    Flisak, B
    Rizkalla, S
    ACI STRUCTURAL JOURNAL, 2003, 100 (04) : 499 - 509