Integrated 3D intracardiac ultrasound imaging with detailed pulmonary vein delineation guided fluoroless ablation of atrial fibrillation

被引:7
|
作者
Antolic, Bor [1 ]
Kajdic, Nina [1 ]
Vrbajnscak, Mojca [1 ]
Jan, Matevz [2 ]
Zizek, David [1 ]
机构
[1] Univ Med Ctr Ljubljana, Dept Cardiol, Zaloska 7, Ljubljana 1000, Slovenia
[2] Univ Med Ctr Ljubljana, Dept Cardiovasc Surg, Ljubljana, Slovenia
来源
关键词
atrial fibrillation; cartosound; fluoroless; intracardiac ultrasound; zero fluoroscopy; CATHETER ABLATION; ECHOCARDIOGRAPHY;
D O I
10.1111/pace.14315
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Intracardiac echocardiography (ICE) has become an all-round tool for ablation of atrial fibrillation (AF) since it plays an important role in all procedural steps. The key upgrade to the usefulness of ICE is its integration into three-dimensional (3D) electroanatomic mapping (EAM) system (ICE/EAM automatic integration system). The aim of this single-center retrospective study was to evaluate feasibility, safety and acute efficacy of ICE/EAM automatic integration system guided fluoroless ablation of AF. Methods The study included patients with symptomatic paroxysmal or persistent AF undergoing first pulmonary vein isolation (PVI) radiofrequency (RF) catheter ablation (RFCA) from September 2017 to August 2020. All procedures were performed without the use of fluoroscopy. A detailed 3D virtual anatomy of the left atrium (LA) and structures relevant to AF ablation was constructed from ultrasound contours obtained with ICE probe inside the LA. Pulmonary veins (PVs) and antral regions were additionally mapped with fast anatomical mapping (FAM). PVI was performed with contact force (CF) sensing catheter. Procedural endpoint was successful PVI. Results A total of 98 consecutive patients underwent RFCA (34.7% females, median age 64.4 years, 64.3% paroxysmal AF). Acute PVI was achieved in all patients (100%). Forty-three patients (43.9%) underwent additional ablations for concomitant arrhythmias. Adverse events were detected in four patients (4.1%). The median procedure duration was 130 min (IQR 103.8-151.3). If only PVI was done the median procedure duration was 110.5 (IQR 100.0-133.8) Conclusions ICE/EAM automatic integration system guided fluoroless ablation of AF is feasible, safe and acutely effective method for treatment of symptomatic AF.
引用
收藏
页码:1487 / 1496
页数:10
相关论文
共 50 条
  • [41] Integrated catheter for 3-D intracardiac echo cardiography and ultrasound ablation
    Gentry, KL
    Smith, SW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (07) : 800 - 808
  • [42] Intracardiac echo guided pulmonary veins isolation improves success rates and incidence of pulmonary vein stenosis in patients with atrial fibrillation
    Marrouche, NF
    Saliba, W
    Martin, DO
    Gillinov, M
    McCarthy, P
    Bash, D
    Saad, EB
    Bhargava, M
    Rosenberg, S
    Schweikert, R
    Andrews-Williams, M
    Natale, A
    CIRCULATION, 2002, 106 (19) : 500 - 500
  • [43] 3D Real-Time TEE During Pulmonary Vein Isolation in Atrial Fibrillation
    Acena, Marta
    Regoli, Francois
    Faletra, Francesco Fulvio
    Tritto, Massimo
    Klersy, Catherine
    Murzilli, Romina
    Scopigni, Francesca
    Penco, Maria
    Pasotti, Elena
    Moccetti, Tiziano
    Auricchio, Angelo
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (07) : 737 - 738
  • [44] Ultrasound-guided femoral vein access in patients undergoing atrial fibrillation ablation with uninterrupted anticoagulation
    Gianni, C.
    Monreal, C.
    Powers, B. M.
    Trivedi, C.
    Mohanty, S.
    Gokoglan, Y.
    Al-Ahmad, A.
    Burkhardt, J. D.
    Gallinghouse, G. J.
    Horton, R. P.
    Hranitzky, P. M.
    Sanchez, J. E.
    Beheiry, S.
    Di Biase, L.
    Natale, A.
    EUROPEAN HEART JOURNAL, 2016, 37 : 1080 - 1080
  • [45] Heart in 3D and navigation, "as in the GPS" for ablation of atrial fibrillation
    Stec, Sebastian
    KARDIOLOGIA POLSKA, 2012, 70 (09) : 931 - 931
  • [46] Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index
    Sun, Yuanjun
    Xiao, Xianjie
    Yin, Xiaomeng
    Gao, Lianjun
    Yu, Xiaohong
    Zhang, Rongfeng
    Wang, Zhongzhen
    Dai, Shiyu
    Yang, Yanzong
    Xia, Yunlong
    BMC CARDIOVASCULAR DISORDERS, 2022, 22 (01)
  • [47] Extensive Posterior Wall Isolation on Top of Pulmonary Vein Isolation Guided by Ablation Index in Persistent Atrial Fibrillation Ablation
    Sabatino, Francesco
    Oriente, Domenico
    Fortunato, Fabrizio
    Cascino, Antonio
    Ferrara, Giuliano
    Sgarito, Giuseppe
    Conti, Sergio
    LIFE-BASEL, 2023, 13 (03):
  • [48] Impact of baseline impedance of pulmonary vein antrum on success of catheter ablation for paroxysmal atrial fibrillation guided by ablation index
    Yuanjun Sun
    Xianjie Xiao
    Xiaomeng Yin
    Lianjun Gao
    Xiaohong Yu
    Rongfeng Zhang
    Zhongzhen Wang
    Shiyu Dai
    Yanzong Yang
    Yunlong Xia
    BMC Cardiovascular Disorders, 22
  • [49] Intracardiac Echo for Registration of Rotational Angiography Based Left Atrial Reconstructions: A Novel Approach Integrating Two Intraprocedural 3D Imaging Techniques in Atrial Fibrillation Ablation
    Noelker, Georg
    Gutieben, Klaus J.
    Ritscher, Guido
    Sinha, Anil
    Marrouche, Nassir
    Heintze, Johannes
    Vogt, Juergen
    Horstkotte, Dieter
    Brachmann, Johannes
    CIRCULATION, 2009, 120 (18) : S628 - S628
  • [50] 3D MRI left atrial scar map guided anatomical pulmonary vein reisolation
    Fodi Eszter
    van der Geest Rob J
    Toth Attila
    Simor Tamas
    ORVOSI HETILAP, 2022, 163 (19) : 767 - 772