Feasibility and safety of a new generation of gore septal occluder device in children

被引:1
|
作者
Lombardi, Maristella [1 ]
Tagliente, Maria R. [1 ]
Pirolo, Teodoro [1 ]
Massari, Elena [1 ]
Milella, Leonardo [1 ]
Vairo, Ugo [1 ]
机构
[1] Osped Pediat Giovanni XXIII, Dept Pediat Cardiol, Bari, Italy
关键词
atrial septal defect; children; device; transcatheter occlusion; PERCUTANEOUS CLOSURE; NATURAL-HISTORY; DEFECT; EXPERIENCE;
D O I
10.2459/JCM.0000000000000036
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim Transcatheter closure of an ostium secundum atrial septal defect (ASD) is now considered the standard care for most of children with the appropriate anatomy, and is a relatively well-tolerated procedure to reduce the clinical sequelae of ASD, with a low complication rate. Methods The present case reports describe our clinical experience of the percutaneous closure of a secundum ASD in 10 children between December 2011 and November 2012, by means of a new generation of device, the GORE Septal Occluder device. Results The implantation was successful in all except two cases, the device being properly placed and deployed without malposition or embolization in the catheterization laboratory. No complications were related to the procedure. The successful implant was confirmed and no major adverse events were documented in the following 3-12 months. Conclusion The new GORE Septal Occluder device appears to be a feasible, well-tolerated and successful tool for the closure of an ASD of 15mm or less in childhood.
引用
收藏
页码:E249 / E251
页数:3
相关论文
共 50 条
  • [31] Device-Related Thrombosis After Transcatheter Closure of Atrial Septal Defect Using the Gore Cardioform ASD Occluder
    Moolla, Muhammad
    Linjawi, Hatem
    Taylor, Dylan
    Mathew, Anoop
    JOURNAL OF INVASIVE CARDIOLOGY, 2024, 36 (07):
  • [32] Initial use of the new GORE® septal occluder in patent foramen ovale closure: Implantation and preliminary results
    MacDonald, Simon T.
    Daniels, Matthew J.
    Ormerod, Oliver J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (04) : 660 - 665
  • [33] Left atrial disc device thrombosis after atrial defect closure with the Gore® Cardioform septal occluder: A case series
    Kramer, Peter
    Opgen-Rhein, Bernd
    Berger, Felix
    Nordmeyer, Johannes
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2023, 102 (02) : 359 - 363
  • [34] ASSURED clinical study: New GORE® CARDIOFORM ASD occluder for transcatheter closure of atrial septal defect
    Sommer, Robert J.
    Love, Barry A.
    Paolillo, Joseph A.
    Gray, Robert G.
    Goldstein, Bryan H.
    Morgan, Gareth J.
    Gillespie, Matthew J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (07) : 1285 - 1295
  • [35] Around PediHeart: Amplatzer Septal Occluder® Device
    Francis McCaffrey
    Pediatric Cardiology, 2002, 23 (1) : 83 - 83
  • [36] Cinematic Rendering of an Atrial Septal Occluder Device
    Recht, Hannah S.
    Fishman, Elliot K.
    RADIOLOGY, 2020, 294 (03) : 507 - 507
  • [37] LATE EROSION OF AN AMPLATZER SEPTAL OCCLUDER DEVICE
    Cherian, Sanjay
    Kalangos, Afksendiyos
    Cikirikcioglu, Mustafa
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 143 (03): : 760 - 761
  • [38] Helex septal occluder: Feasibility study of closure of atrial septal defect
    El-Sisi, Amal Mahmoud
    Gendi, Salwa
    Dilawar, Mohammed
    Numan, Mohamed
    PEDIATRIC CARDIOLOGY, 2008, 29 (01) : 84 - 89
  • [39] Remote Embolization of an Atrial Septal Occluder Device
    Singh, Ajmer
    Nanda, Chinmaya
    Mehta, Yatin
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (04) : 1054 - 1055
  • [40] Atrial Septal Occluder Device Embolization is Avoidable
    Devarakonda, Bhargava, V
    Kapoor, Mukul C.
    ANNALS OF CARDIAC ANAESTHESIA, 2023, 26 (02) : 122 - 123