Differences in force normalising procedures during submaximal anisometric contractions

被引:3
|
作者
Skarabot, Jakob [1 ]
Ansdell, Paul [1 ]
Brownstein, Callum [1 ]
Howatson, Glyn [1 ,2 ]
Goodall, Stuart [1 ]
Durbaba, Rade [1 ]
机构
[1] Northumbria Univ, Fac Hlth & Life Sci, Newcastle Upon Tyne, Tyne & Wear, England
[2] Northwest Univ, Sch Environm Sci & Dev, Water Res Grp, Potchefstroom, South Africa
关键词
Concentric; Eccentric; Electromyography; Lengthening; Shortening; Submaximal; LENGTHENING CONTRACTIONS; VOLUNTARY ACTIVATION; MOTONEURON POOL; FLEXOR MUSCLES; KNEE EXTENSORS; MODULATION; EXCITABILITIES; STIMULATION; INTENSITY; DISCHARGE;
D O I
10.1016/j.jelekin.2018.05.009
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Eccentric contractions are thought to require a unique neural activation strategy. However, due to greater intrinsic force generating capacity of muscle fibres during eccentric contraction, the understanding of neural modulation of different contraction types during submaximal contractions may be impeded by the force normalisation procedure employed. In the present experiment, subjects performed maximal isometric dorsiflexion at shorter (80 degrees), intermediate (90 degrees) and longer (100 degrees) muscle lengths, and maximal concentric and eccentric contractions. Thereafter, submaximal concentric and eccentric contractions were performed normalised to either isometric maximum at 90 degrees (ISO), contraction type specific maximum (CTS) or muscle length specific maximum (MLS). When using ISO or MLS for normalisation, mean submaximal eccentric torque levels were significantly lower when compared to CTS normalisation (11 and 7% lower compared to CTS; p = 0.003 and p = 0.018 for ISO and MLS, respectively). These experimentally observed differences closely matched those expected from the predictive model. During submaximal concentric contraction, mean torque levels were similar between ISO and CTS normalisation with similar discrepancies noted in EMG activity. These findings suggest that normalising to ISO and MLS might not be accurate for assessment and prescription of submaximal eccentric contractions.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [31] Fatigue effects on motor unit activity during submaximal contractions
    Conwit, RA
    Stashuk, D
    Suzuki, H
    Lynch, N
    Schrager, M
    Metter, EJ
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2000, 81 (09): : 1211 - 1216
  • [32] QUANTITATIVE SURFACE EMG DURING SUSTAINED AND INTERMITTENT SUBMAXIMAL CONTRACTIONS
    CHRISTENSEN, H
    FUGLSANGFREDERIKSEN, A
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1988, 70 (03): : 239 - 247
  • [33] Deltoid Electromyography is Reliable During Submaximal Isometric Ramp Contractions
    Phillips, David
    Karduna, Andrew
    JOURNAL OF APPLIED BIOMECHANICS, 2017, 33 (03) : 237 - 240
  • [34] Reflex regulation during sustained and intermittent submaximal contractions in humans
    Duchateau, J
    Balestra, C
    Carpentier, A
    Hainaut, K
    JOURNAL OF PHYSIOLOGY-LONDON, 2002, 541 (03): : 959 - 967
  • [35] A model of ''sense of effort'' during maximal and submaximal contractions of the tongue
    Somodi, LB
    Robin, DA
    Luschei, ES
    BRAIN AND LANGUAGE, 1995, 51 (03) : 371 - 382
  • [36] Alternating or Bilateral Exercise Training does not Influence Force Control during Single-Leg Submaximal Contractions with the Dorsiflexors
    Petrovic, Ivana
    Amiridis, Ioannis G.
    Holobar, Ales
    Trypidakis, Georgios
    Sahinis, Chrysostomos
    Kannas, Theodoros
    Kellis, Eleftherios
    Enoka, Roger M.
    JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2023, 22 (02) : 245 - 253
  • [37] The effect of metabolic acidosis on maximal force production and muscle recruitment during repeated, submaximal calf contractions to task failure
    Siegler, Jason
    Poulsen, Mathias
    Nielsen, Niels-Peter
    Kennedy, David
    Marshall, Paul
    Green, Simon
    FASEB JOURNAL, 2014, 28 (01):
  • [38] Sex differences in the fatigability of arm muscles depends on absolute force during isometric contractions
    Hunter, SK
    Enoka, RM
    JOURNAL OF APPLIED PHYSIOLOGY, 2001, 91 (06) : 2686 - 2694
  • [39] Eccentric exercise-induced muscle weakness abolishes sex differences in fatigability during sustained submaximal isometric contractions
    Jodoin, Hanna L.
    Hinks, Avery
    Roussel, Olivia P.
    Contento, Vincenzo S.
    Dalton, Brian H.
    Power, Geoffrey A.
    JOURNAL OF SPORT AND HEALTH SCIENCE, 2023, 12 (04) : 523 - 533
  • [40] Method of analysis influences interpretations of sex- related differences in firing rates during prolonged submaximal isometric contractions
    Dimmick, Hannah L.
    Trevino, Michael A.
    Miller, Jonathan D.
    Parra, Mandy E.
    Sterczala, Adam J.
    Herda, Trent J.
    JOURNAL OF MUSCULOSKELETAL & NEURONAL INTERACTIONS, 2022, 22 (01) : 27 - 36