Accurate one-end fault location for overhead transmission lines in interconnected power systems

被引:23
|
作者
Eisa, Amir A. A. [1 ]
Ramar, K. [1 ]
机构
[1] Multimedia Univ, Fac Engn, Cyberjaya 63100, Malaysia
关键词
Fault location; Transmission lines; Distributed parameters; One-end measurements; ALGORITHM;
D O I
10.1016/j.ijepes.2009.11.005
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new one-end fault location method for overhead transmission lines embedded in a general n-bus interconnected power system. High accuracy in fault location is achieved by using both an accurate distributed parameters model for the faulted transmission line, and a two-bus Thevenin equivalent network model for the power system that accurately accounts for its interconnectivity. The method has been tested using transient fault data obtained from PSCAD/EMTDC simulations of an 11-bus interconnected power system. The results obtained indicate that the method is capable of estimating the fault distance with high accuracy for various fault conditions. They also indicate that method is sensitive to errors in the value of the local bus impedance, but is insensitive to errors in the value of the remote bus impedance. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:383 / 389
页数:7
相关论文
共 50 条
  • [21] An accurate fault location algorithm for parallel transmission lines using one-terminal data
    Song Guobing
    Jiale, Suonan
    Ge Yaozhong
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2009, 31 (2-3) : 124 - 129
  • [22] Increase of Accuracy of the Fault Location Methods for Overhead Electrical Power Lines
    Lebedev, Vladimir
    Filatova, Galina
    Timofeev, Alexander
    [J]. ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2018, 2018
  • [23] A new algorithm for fault location in power transmission lines
    Sadeh, J
    Ranjbar, AM
    [J]. PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 61 - I AND II, 1999, 61 : 458 - 462
  • [24] Enhancing fault location performance on power transmission lines
    Bockarjova, Marija
    Dolgicers, Aleksandrs
    Sauhats, Antans
    [J]. 2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, : 1123 - +
  • [25] A Fault Location and Realization Method for Overhead High Voltage Power Transmission
    Jiang Zhen Bao
    Zhong Tingjian
    Ye Mao
    [J]. CEIS 2011, 2011, 15
  • [26] Field Tests of a Traveling Wave Fault Location Service for Overhead Transmission Lines
    Lachugin V.F.
    Platonov P.S.
    Alekseev V.G.
    Vazyulin M.V.
    Mitrofanov N.N.
    Popov S.G.
    Izmukov G.N.
    Podshivalin A.N.
    Artyunov S.A.
    Klyushkin N.G.
    Shemetov A.S.
    [J]. Power Technology and Engineering, 2022, 55 (05) : 783 - 789
  • [27] Accurate location of faults on power transmission lines with use of two-end unsynchronized measurements
    Izykowski, J
    Molag, R
    Rosolowski, E
    Saha, MM
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 627 - 633
  • [28] An accurate scheme for fault location in combined overhead line with underground power cable
    Gilany, M
    El Din, EST
    Aziz, MMA
    Ibrahim, DK
    [J]. 2005 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS, 1-3, 2005, : 2521 - 2527
  • [29] Fault Location on Power Transmission Lines with Use of Two-End Synchronised and Unsynchronised Measurements
    Izykowski, Jan
    Rosolowski, Eugeniusz
    [J]. 11TH INTERNATIONAL SCIENTIFIC CONFERENCE ELECTRIC POWER ENGINEERING 2010, PROCEEDINGS, 2010, : 23 - 28
  • [30] Review of Error Sources in One-End Data Impedance-Based Fault Location Algorithms
    Dragomir, Marian
    Istrate, Marcel
    Dragomir, Alin
    [J]. 2018 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE), 2018, : 315 - 319