Comparison of Dosimetry and Late Toxicity Between Split Ring and Tandem and Ovoid HDR Brachytherapy Applicators in Cervical Cancer

被引:0
|
作者
Ishaq, O. [1 ]
Talcott, W. [2 ]
Duckworth, T. [2 ]
Lymberis, S. [1 ]
Schiff, P. B. [2 ,3 ]
机构
[1] NYU, Ctr Canc, New York, NY USA
[2] NYU, Sch Med, New York, NY USA
[3] NYU, Langone Med Ctr, New York, NY USA
关键词
D O I
10.1016/j.ijrobp.2015.07.1274
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
2718
引用
收藏
页码:E288 / E288
页数:1
相关论文
共 50 条
  • [1] Dosimetric Comparison Between Split Ring and Tandem & Ovoid HDR Brachytherapy Applicators in Cervical Cancer Treatment
    Ishaq, O.
    Montgomery, J. R.
    Duckworth, T.
    Hsu, H.
    Schiff, P. B.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S857 - S857
  • [2] Intrapatient Dosimetric Variability Between Two Adjustable Brachytherapy Applicators for Cervical Cancer: Tandem/Ovoid vs. Tandem/Split-Ring
    Shah, B. A.
    Duckworth, T.
    Jennings, G. T.
    Ishaq, O., Jr.
    Schiff, P. B.
    Lymberis, S. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E635 - E636
  • [3] Dosimetric Comparison Between Split Ring Applicator and Tandem and Ovoids for HDR Brachytherapy Boost in Cervical Cancer
    Hsu, H.
    Duckworth, T.
    Schiff, P.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (02): : S891 - S892
  • [4] A comparison of tandem ring and tandem ovoid treatment as a curative brachytherapy component for cervical cancer
    Gursel, Sukriye Bilge
    Serarslan, Alparslan
    Meydan, Ahmet Deniz
    Okumus, Nilgun
    Yasayacak, Tenzile
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2020, 12 (02) : 111 - 117
  • [5] Spatial and Dosimetric Comparison of Tandem/Ring Applicator Against Adjustable Tandem/Ovoid and Tandem/Split-Ring for Intracavitary Brachytherapy Treatment of Cervical Cancer
    Talcott, W. J.
    Duckworth, T.
    Wu, S. P. P.
    Ishaq, O.
    Walton, R. M.
    Osterman, K. S.
    Schiff, P. B.
    Lymberis, S. C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E312 - E312
  • [6] An Algorithm for Fully Automated Catheter Digitization of the Tandem and Ovoid Applicators in HDR Brachytherapy
    Yan, B.
    Deufel, C.
    Petersen, I.
    Haddock, M.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E162 - E162
  • [7] Dosimetric Comparison of Tandem and Ovoid (TO) Vs. Tandem and Ring (TR) Applicators in High-Dose Rate (HDR) Brachytherapy (BT) for the Treatment of Locally-Advanced Cervical-Cancer
    Kuo, L.
    Viswanathan, A.
    Damato, A.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3404 - 3404
  • [8] Automated Dose Point Placement for Cervical Cancer Brachytherapy Using Tandem and Ovoid Applicators
    Kang, H.
    Padilla, L.
    Hasan, Y.
    Al-Hallaq, H.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3364 - 3364
  • [9] Dosimetric evaluation of image based brachytherapy using tandem ovoid and tandem ring applicators
    Rangarajan, Ramya
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2018, 23 (01) : 57 - 60
  • [10] DOSE EFFECTS DUE TO DISPLACEMENTS OF TANDEM OVOID APPLICATORS DURING PDR BRACHYTHERAPY FOR CERVICAL CANCER.
    Lotz, H.
    Moerland, M.
    Tersteeg, R.
    Jurgenliemk-Schulz, I.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S185 - S185