The Flexor Pollicis Longus Reflex Interrater and Intrarater Reliability in Comparison With Established Muscle Stretch Reflexes

被引:1
|
作者
Gladitz, Luisa Marilena [1 ]
Schoettker-Koeniger, Thomas [2 ]
Sturm, Christian [1 ]
Gutenbrunner, Christoph [1 ]
Ranker, Alexander [1 ]
机构
[1] Hannover Med Sch, Dept Rehabil Med, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Univ Appl Sci & Art, Hildesheim, Germany
关键词
Muscle Stretch Reflex; Neurologic Diagnostic Technique; Clinical Examination; Flexor Pollicis Longus; PRONATOR-TERES REFLEX; CERVICAL RADICULOPATHY; OBSERVER AGREEMENT;
D O I
10.1097/PHM.0000000000001731
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: The aim of this study was to investigate the interrater reliability and intrarater reliability of the flexor pollicis longus muscle stretch reflex (FPLR) and compare it with clinically established reflexes. Design: A total of 71 healthy volunteers participated. The FPLR, biceps reflex, brachioradialis reflex, and patellar tendon reflex of each participant were tested bilaterally and rated by eight examiners (four experienced, four inexperienced). For intrarater reliability evaluation, five examiners rated the reflexes of four volunteers at four different points in time. Results: Analysis of the interrater reliability withGwet'sAC1 demonstrated almost perfect agreement for FPLR (Gwet's AC1 = 0.90), biceps reflex (Gwet's AC1 = 0.90), and patellar tendon reflex (Gwet's AC1 = 0.95) when using binary data (reflex present vs. absent). Only fair agreement was found for the brachioradialis reflex (Gwet's AC1 = 0.56). Experienced raters had a higher agreement than inexperienced raters did when rating the biceps reflex and the patellar tendon reflex. The intrarater reliability was almost perfect for the patellar tendon reflex (Gwet's AC1 = 0.94), followed by the FPLR (Gwet's AC1 = 0.83) with substantial agreement and the biceps reflex (Gwet's AC1 = 0.57) with moderate agreement. Conclusion: The FPLR is a reliable diagnostic neuromuscular test and may therefore be useful in the clinical examination for C8/T1 nerve root lesions or pathologies of the interosseous anterior nerve.
引用
收藏
页码:539 / 545
页数:7
相关论文
共 50 条
  • [31] Measurement of tendon excursion velocity with colour Doppler imaging: A preliminary study on flexor pollicis longus muscle
    Cigali, BS
    Buyruk, HM
    Snijders, CJ
    Lameris, JS
    Holland, WPJ
    Mesut, R
    Stam, HJ
    EUROPEAN JOURNAL OF RADIOLOGY, 1996, 23 (03) : 217 - 221
  • [32] Does three months of nightly splinting reduce the extensibility of the flexor pollicis longus muscle in people with tetraplegia?
    Harvey, Lisa
    Baillie, Rowena
    Ritchie, Bronwyn
    Simpson, David
    Pironello, Dallas
    Glinsky, Joanne
    PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2007, 12 (01) : 5 - 13
  • [33] REFLEX RESPONSES INDUCED IN HUMAN FINGER FLEXOR MUSCLES BY RHYTHMICAL STRETCH OF MUSCLE
    ALLEGAERT, G
    BERGMANS, J
    DOM, L
    MICHAUX, J
    ARCHIVES INTERNATIONALES DE PHYSIOLOGIE ET DE BIOCHIMIE, 1969, 77 (01): : 132 - +
  • [34] Interrater and intrarater reliability of the pectoralis minor muscle length measurement in subjects with and without shoulder impingement symptoms
    Struyf, Filip
    Meeus, Mira
    Fransen, Erik
    Roussel, Nathalie
    Jansen, Nick
    Truijen, Steven
    Nijs, Jo
    MANUAL THERAPY, 2014, 19 (04) : 294 - 298
  • [35] Accessory head of flexor pollicis longus muscle in fetuses and adult cadavers and its relation to anterior interosseous nerve
    Kara, Alev
    Elvan, Ozlem
    Yildiz, Selda
    Ozturk, Hakan
    CLINICAL ANATOMY, 2012, 25 (05) : 601 - 608
  • [36] Prevalence of accessory head of flexor pollicis longus muscle and its relation to anterior interosseous nerve in Thai population
    Mahakkanukrauh, P
    Surin, P
    Ongkana, N
    Sethadavit, M
    Vaidhayakarn, P
    CLINICAL ANATOMY, 2004, 17 (08) : 631 - 635
  • [37] ISOLATED PARALYSIS OF FLEXOR POLLICIS LONGUS MUSCLE - UNUSUAL VARIATION OF ANTERIOR INTEROSSEOUS NERVE SYNDROME - CASE REPORT
    KRAG, C
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1974, 8 (03): : 250 - 252
  • [38] Interrater and Intrarater Reliability of Electrical Impedance Myography: A Comparison between Large and Small Handheld Electrode Arrays
    Hu, Huijing
    Lo, Wai Leung Ambrose
    Wang, Xiaoyun
    Li, Le
    Zhou, Ping
    JOURNAL OF HEALTHCARE ENGINEERING, 2021, 2021
  • [39] Interrater and Intrarater Reliability of Transverse Abdominal and Lumbar Multifidus Muscle Thickness in Subjects With and Without Low Back Pain
    Djordjevic, Olivera
    Djordjevic, Aleksandar
    Konstantnovic, Ljubica
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2014, 44 (12): : 979 - 988
  • [40] RECURRENT FACILITATION OF MONOSYNAPTIC FLEXOR REFLEX DURING DYNAMIC STRETCH OF TRICEPS SURAE MUSCLE
    BENECKE, R
    BOTTCHER, U
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1973, 343 : R74 - R74