First results of the new scanning transmission X-ray microscope at BESSY-II

被引:5
|
作者
Wiesemann, U
Thieme, J
Guttmann, P
Früke, R
Rehbein, S
Niemann, B
Rudolph, D
Schmahl, G
机构
[1] Univ Gottingen, Inst Xray Phys, D-37073 Gottingen, Germany
[2] RheinAhrCampus Remagen, D-53424 Remagen, Germany
[3] Royal Inst Technol, SCFAB, S-10691 Stockholm, Sweden
来源
JOURNAL DE PHYSIQUE IV | 2003年 / 104卷
关键词
D O I
10.1051/jp4:200300037
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
A new scanning transmission X-ray microscope (STXM) has been built at the undulator U41 of the BESSY II storage ring. The STXM monochromator consists of a plane mirror and a plane grating with varied line density. First NEXAFS spectra of a polyimide foil at the carbon, nitrogen and oxygen K absorption edges are shown. The photon rate in the focal spot is about 10 MHz at the carbon and about 500 MHz at the oxygen K absorption edge. The first images are presented.
引用
收藏
页码:95 / 98
页数:4
相关论文
共 50 条
  • [1] The new scanning transmission X-ray microscope at BESSY II
    Wieseman, U
    Thieme, J
    Guttmann, P
    Niemann, B
    Rudolph, D
    Schmahl, G
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 430 - 434
  • [2] X-ray spectromicroscopy with the scanning transmission X-ray microscope at BESSY II
    Mitrea, G.
    Thieme, J.
    Guttmann, P.
    Heim, S.
    Gleber, S.
    JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 : 26 - 35
  • [3] X-RAY SUPERMIRRORS FOR BESSY-II
    ERKO, A
    SCHAFERS, F
    VIDAL, B
    YAKSHIN, A
    PIETSCH, U
    MAHLER, W
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (10): : 4845 - 4846
  • [4] The transmission X-ray microscope at BESSY II
    Guttmann, P
    Niemann, B
    Rehbein, S
    Knöchel, C
    Rudolph, D
    Schmahl, G
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 85 - 90
  • [5] Construction of a scanning transmission X-ray microscope at the undulator U-41 at BESSY II
    Wiesemann, U
    Thieme, J
    Früke, R
    Guttmann, P
    Niemann, B
    Rudolph, D
    Schmahl, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 861 - 863
  • [6] Generation of sub-picosecond x-ray pulses at BESSY-II
    Khan, S
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 1810 - 1812
  • [7] Comparative monochromator studies for a soft x-ray microfocus beamline for BESSY-II
    Weiss, MR
    Follath, R
    Senf, F
    Gudat, W
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1999, 101 : 1003 - 1012
  • [8] The scanning transmission X-ray microscope at NSRL
    Jiang, S
    Chen, L
    Xu, CY
    Fu, SJ
    Chen, J
    Xu, Z
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 81 - 84
  • [9] The magnetic transmission X-ray microscopy project at BESSY II
    Eimüller, T
    Niemann, B
    Guttmann, P
    Fischer, P
    Englisch, U
    Vatter, R
    Wolter, C
    Seiffert, S
    Schmahl, G
    Schütz, G
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 91 - 94
  • [10] Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: II. Tomography