The new scanning transmission X-ray microscope at BESSY II

被引:0
|
作者
Wieseman, U [1 ]
Thieme, J [1 ]
Guttmann, P [1 ]
Niemann, B [1 ]
Rudolph, D [1 ]
Schmahl, G [1 ]
机构
[1] Univ Gottingen, Inst XRay Phys, D-37073 Gottingen, Germany
来源
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new scanning transmission X-ray microscope (STXM) is under construction and will be operated at the undulator U41 of the BESSY II storage ring. In the monochromator without entrance or exit slits, a plane grating with variable line density is used. A spectral resolution of 2200 to 6500 is expected in the energy range of 680 eV to 200 eV. The sample is located in air so it can be exchanged easily. The photon rate in the focus will be of the order of 10(9)/s at a monochromaticity of 3000. A pnCCD capable of handling this rate will be used as a detector.
引用
收藏
页码:430 / 434
页数:5
相关论文
共 50 条
  • [1] X-ray spectromicroscopy with the scanning transmission X-ray microscope at BESSY II
    Mitrea, G.
    Thieme, J.
    Guttmann, P.
    Heim, S.
    Gleber, S.
    JOURNAL OF SYNCHROTRON RADIATION, 2008, 15 : 26 - 35
  • [2] First results of the new scanning transmission X-ray microscope at BESSY-II
    Wiesemann, U
    Thieme, J
    Guttmann, P
    Früke, R
    Rehbein, S
    Niemann, B
    Rudolph, D
    Schmahl, G
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 95 - 98
  • [3] The transmission X-ray microscope at BESSY II
    Guttmann, P
    Niemann, B
    Rehbein, S
    Knöchel, C
    Rudolph, D
    Schmahl, G
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 85 - 90
  • [4] Construction of a scanning transmission X-ray microscope at the undulator U-41 at BESSY II
    Wiesemann, U
    Thieme, J
    Früke, R
    Guttmann, P
    Niemann, B
    Rudolph, D
    Schmahl, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 861 - 863
  • [5] The scanning transmission X-ray microscope at NSRL
    Jiang, S
    Chen, L
    Xu, CY
    Fu, SJ
    Chen, J
    Xu, Z
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 81 - 84
  • [6] The magnetic transmission X-ray microscopy project at BESSY II
    Eimüller, T
    Niemann, B
    Guttmann, P
    Fischer, P
    Englisch, U
    Vatter, R
    Wolter, C
    Seiffert, S
    Schmahl, G
    Schütz, G
    JOURNAL DE PHYSIQUE IV, 2003, 104 : 91 - 94
  • [7] Soft X-ray microscopy with a cryo scanning transmission X-ray microscope: II. Tomography
    Wang, Y
    Jacobsen, C
    Maser, J
    Osanna, A
    JOURNAL OF MICROSCOPY-OXFORD, 2000, 197 : 80 - 93
  • [9] X-ray microscopes at BESSY II
    Guttmann, P
    Niemann, B
    Thieme, J
    Wiesemann, U
    Rudolph, D
    Schmahl, G
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 411 - 415
  • [10] Scanning transmission X-ray microscope as a lithographic tool
    Leontowich, Adam F. G.
    Hitchcock, Adam P.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239