Competency-based assessment in surgeon-performed head and neck ultrasonography: A validity study

被引:26
|
作者
Todsen, Tobias [1 ,2 ,4 ,5 ]
Melchiors, Jacob [1 ,2 ,4 ,5 ]
Charabi, Birgitte [1 ,2 ]
Henriksen, Birthe [3 ]
Ringsted, Charlotte [6 ]
Konge, Lars [4 ,5 ]
von Buchwald, Christian [1 ,2 ]
机构
[1] Copenhagen Univ Hosp, Rigshosp, Dept Otorhinolaryngol Head & Neck Surg, Copenhagen, Denmark
[2] Copenhagen Univ Hosp, Rigshosp, Audiol, Copenhagen, Denmark
[3] Copenhagen Univ Hosp, Rigshosp, Dept Radiol, Ultrasound Sect,Diagnost Ctr, Copenhagen, Denmark
[4] Univ Copenhagen, Copenhagen Acad Med Educ & Simulat, Copenhagen, Denmark
[5] Capital Reg Denmark, Copenhagen, Denmark
[6] Aarhus Univ, Fac Hlth, Ctr Hlth Sci Educ, Aarhus, Denmark
来源
LARYNGOSCOPE | 2018年 / 128卷 / 06期
关键词
Head and neck ultrasonography; surgeon-performed ultrasonography; diagnostic accuracy; competence-based assessment; validity; OF-CARE ULTRASONOGRAPHY; THYROID-CANCER; ULTRASOUND; OFFICE; SKILLS; STATEMENT; CONSENSUS; OUTCOMES; CURVES;
D O I
10.1002/lary.26841
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
ObjectiveHead and neck ultrasonography (HNUS) increasingly is used as a point-of-care diagnostic tool by otolaryngologists. However, ultrasonography (US) is a very operator-dependent image modality. Hence, this study aimed to explore the diagnostic accuracy of surgeon-performed HNUS and to establish validity evidence for an objective structured assessment of ultrasound skills (OSAUS) used for competency-based assessment. Study DesignA prospective experimental study. MethodsSix otolaryngologists and 11 US novices were included in a standardized test setup for which they had to perform focused HNUS of eight patients suspected for different head and neck lesions. Their diagnostic accuracy was calculated based on the US reports, and two blinded raters assessed the video-recorded US performance using the OSAUS scale. ResultsThe otolaryngologists obtained a high diagnostic accuracy on 88% (range 63%-100%) compared to the US novices on 38% (range 0-63%); P<0.001. The OSAUS score demonstrated good inter-case reliability (0.85) and inter-rater reliability (0.76), and significant discrimination between otolaryngologist and US novices; P<0.001. A strong correlation between the OSAUS score and the diagnostic accuracy was found (Spearman's , 0.85; P<P 0.001), and a pass/fail score was established at 2.8. ConclusionStrong validity evidence supported the use of the OSAUS scale to assess HNUS competence with good reliability, significant discrimination between US competence levels, and a strong correlation of assessment score to diagnostic accuracy. An OSAUS pass/fail score was established and could be used for competence-based assessment in surgeon-performed HNUS. Level of EvidenceNA. Laryngoscope, 128:1346-1352, 2018
引用
收藏
页码:1346 / 1352
页数:7
相关论文
共 50 条
  • [31] Surgeon-performed intraoperative transoral ultrasound improves the detection of human papillomavirus-positive head and neck cancers of unknown primary
    Garset-Zamani, Martin
    Lomholt, Anne Fog
    Charabi, Birgitte Wittenborg
    Norling, Rikke
    Dejanovic, Danijela
    Hall, Johanna Maria
    Makouei, Fatemeh
    Agander, Tina Klitmoller
    Ersboll, Annette Kjaer
    von Buchwald, Christian
    Todsen, Tobias
    ORAL ONCOLOGY, 2024, 159
  • [32] Competency-Based Assessment Center Design: A Case Study
    Melancon, Sylvia C.
    Williams, Martha S.
    ADVANCES IN DEVELOPING HUMAN RESOURCES, 2006, 8 (02) : 283 - 314
  • [33] Evaluation of Surgeon-Performed Ultrasonography With or Without Contrast Enhancement vs Scintigraphy in Patients With Primary Hyperparathyroidism
    Michaelsen, Sanne Hoxbroe
    Bay, Mette
    Gerke, Oke
    Vestergaard, Sys
    Graumann, Ole
    Nielsen, Viveque Egsgaard
    Madsen, Anders Rorbaek
    Bonnema, Steen Joop
    Godballe, Christian
    JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2023, 149 (06) : 531 - 539
  • [34] Surgeon-performed bedside ultrasound to assess volume status: a feasibility study
    Deidre L. Wyrick
    Samuel D. Smith
    Jeffrey M. Burford
    Christopher J. Swearingen
    Melvin S. Dassinger
    Pediatric Surgery International, 2015, 31 : 1165 - 1169
  • [35] Surgeon-performed transcutaneous laryngeal ultrasound for vocal cord assessment after total thyroidectomy: a prospective study
    Rossi, Leonardo
    Papini, Piermarco
    De Palma, Andrea
    Fregoli, Lorenzo
    Becucci, Chiara
    Ambrosini, Carlo Enrico
    Morganti, Riccardo
    Materazzi, Gabriele
    LANGENBECKS ARCHIVES OF SURGERY, 2024, 409 (01)
  • [36] Surgeon-performed bedside ultrasound to assess volume status: a feasibility study
    Wyrick, Deidre L.
    Smith, Samuel D.
    Burford, Jeffrey M.
    Swearingen, Christopher J.
    Dassinger, Melvin S.
    PEDIATRIC SURGERY INTERNATIONAL, 2015, 31 (12) : 1165 - 1169
  • [37] Surgeon-Performed Ultrasound as Preoperative Localization Study in Patients with Primary Hyperparathyroidism
    van Ginhoven, T. M.
    Morks, A. N.
    Schepers, T.
    de Graaf, P. W.
    Smit, P. C.
    EUROPEAN SURGICAL RESEARCH, 2011, 47 (02) : 70 - 74
  • [38] The power of subjectivity in competency-based assessment
    Virk, A.
    Joshi, A.
    Mahajan, R.
    Singh, T.
    JOURNAL OF POSTGRADUATE MEDICINE, 2020, 66 (04) : 200 - 205
  • [39] Assessment in the competency-based approach in general
    Chartier, Samuel
    Le Breton, Julien
    Ferrat, Emilie
    Compagnon, Laurence
    Attali, Claude
    Renard, Vincent
    EXERCER-LA REVUE FRANCOPHONE DE MEDECINE GENERALE, 2013, 24 (108): : 171 - 177
  • [40] Assessment to Transform Competency-based Curricula
    Farris, Karen B.
    Demb, Ada
    Janke, Kristin Kari
    Kelley, Katherine
    Scott, Steven A.
    AMERICAN JOURNAL OF PHARMACEUTICAL EDUCATION, 2009, 73 (08)