Electric Field Distribution Calculation and Analysis of Composite Insulators Operating on Double Circuit Transposition Tower in 500kV Transmission Lines

被引:0
|
作者
Guo, Chenjun [1 ]
Liu, Lishuai [2 ]
Yu, Hong [1 ]
Ma, Yi [1 ]
Mei, Hongwei [2 ]
Wang, Liming [2 ]
机构
[1] Yunnan Power Grid Co Ltd, Elect Power Res Inst, Kunming 650217, Yunnan, Peoples R China
[2] Tsinghua Univ, Grad Sch Shenzhen, Shenzhen 518055, Guangdong, Peoples R China
关键词
D O I
10.1109/icempe.2019.8727278
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transposition tower is generally used in AC transmission line to change the configuration of conductors and mitigate the imbalance of voltage and current. Due to the special conductor configurations, the composite insulators on transposition tower are more likely to be damaged when compared with those on ordinary transmission tower. In this paper, a full-scale three-dimensional simulation model of double circuit transposition tower used in 500 kV transmission lines was built and the finite element method was used to compute the electric field distribution along composite insulators considering the effects of tower, conductor configurations, grading rings, fittings and phase interaction. The regularity of electric field distribution on the surface of composite insulators was researched and the differences between transposition tower and ordinary transmission tower were presented in simulation results. At last, some suggestions were provided to optimize electric field distribution and extend service life of composite insulators on transposition tower in this paper.
引用
收藏
页码:486 / 489
页数:4
相关论文
共 50 条
  • [31] Potential Distribution Analysis of Y-type Insulators in UHV 1000kV Double Circuit Transmission Lines
    Liao, Jintao
    Peng, Zongren
    Wang, Qingyu
    2015 IEEE 11TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, 2015, : 576 - 579
  • [32] Study on calculation model of the lightning protection performance of shielding failure for 500kV double circuit transmission line
    Zhang, ZJ
    Sima, WX
    Liao, RJ
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 122 - 124
  • [33] A calculation method for the electric field under double-circuit HVDC transmission lines
    Yang, Yong
    Lu, Jiayu
    Lei, Yinzhao
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1736 - 1742
  • [35] Analysis of Green Algae Contamination on 500kV Silicone Rubber Composite Insulators
    Xie, Congzhen
    Li, Chaohong
    Zhu, Wen
    Gan, Yongye
    2017 1ST INTERNATIONAL CONFERENCE ON ELECTRICAL MATERIALS AND POWER EQUIPMENT (ICEMPE), 2017, : 664 - 666
  • [36] Investigation on Natural Contamination Deposition of Insulators on ±500kV DC Transmission Lines in Different Environments
    Liu, Qin
    2013 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2013, : 347 - 349
  • [37] The analysis of galloping-endurance character of 500kV power transmission tower
    Yang, Xiaohui
    Zhang, Bo
    Lou, Wenjuan
    Fu, Zhengcai
    MEASUREMENT TECHNOLOGY AND ENGINEERING RESEARCHES IN INDUSTRY, PTS 1-3, 2013, 333-335 : 2123 - +
  • [38] Lightning protection performance of quadruple-circuit 500 kV transmission lines on the same tower with composite cross arm
    Li, Haichen
    Xiang, Nianwen
    Bao, Hua
    Jin, Miao
    Ding, Lijian
    ENERGY REPORTS, 2022, 8 : 520 - 526
  • [39] A Novel Protection of Transmission Lines for Two ±500kV HVDC Systems Erected on the Same Tower
    Huang Min
    Wang Gang
    Luo Huihui
    Liang Yuansheng
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 3669 - 3674
  • [40] Research on Eliminating Closing Resistors in 500kV and above Transmission lines circuit Breakers
    Tian Shu
    Guo Peng-jun
    He Jin-peng
    ELECTRICAL INFORMATION AND MECHATRONICS AND APPLICATIONS, PTS 1 AND 2, 2012, 143-144 : 3 - 7