Clinical and radiological Comparison of treatment of atlantoaxial instability by posterior C1-C2 transarticular screw fixation or C1 lateral mass-C2 pedicle screw fixation

被引:59
|
作者
Lee, Sun-Ho [1 ]
Kim, Eun Sang [1 ]
Sung, Joo-Kyung [2 ]
Park, Yeun-Mook [2 ]
Eoh, Whan [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Neurosurg, Samsung Med Ctr, Seoul 135710, South Korea
[2] Kyungpook Natl Univ, Sch Med, Dept Neurosurg, Taegu, South Korea
关键词
Atlantoaxial; Fixation; Harms technique; Instability; Transarticular screw; POLYAXIAL SCREW; TECHNICAL NOTE; FUSION; COMPLEX; STABILIZATION; ARTHRODESIS; SUITABILITY; SUBLUXATION; EXPERIENCE; GRAFT;
D O I
10.1016/j.jocn.2009.10.008
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We compared the clinical and radiological results of posterior atlantoaxial fixation surgery using transarticular screws to those using a polyaxial screw-rod system in 55 patients with symptomatic atlantoaxial instability Patients underwent posterior C1-C2 fixation 28 patients (group 1) underwent C1-C2 transarticular screw fixation and 27 patients (group 2) underwent C1 lateral mass-C2 pedicle screw fixation Patients were followed-up for at least 24 months The clinical and radiological results were evaluated in the early postoperative period and at 3, 6, 12 and 24 months after surgery Long-term postoperative stability and bone fusion were examined After surgery, 93% of patients in group 1 and 96% of patients in group 2 were free of neck pain The solid fusion rates were 82% for group 1 patients and 96% for group 2 patients at 12 months (p < 0.092) In group 1, three patients showed fibrous union Four patients had hardware failure due to a screw malposition (one in group 1) and pseudoarthrodesis (two in group 1 and one in group 2) One patient in group 1 had cerebrospinal fluid leakage One patient in group 2 had occipital neuralgia One vertebral artery injury occurred during the screw placement in group 1 and another in group 2 during the muscle dissection C1-C2 transarticular screw fixation and C1 lateral mass-C2 pedicle screw fixation both produced excellent results for stabilization of the atlantoaxial complex, but the radiological outcome tended to be superior in C1 lateral mass-C2 pedicle screw fixation (C) 2009 Elsevier Ltd All rights reserved
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
  • [31] Anatomic study for ideal and safe posterior C1-C2 transarticular screw fixation
    Jun, BY
    SPINE, 1998, 23 (15) : 1703 - 1707
  • [32] Atlantoaxial arthrodesis using C1-C2 transarticular screw fixation in a case of Morquio syndrome
    Kulkarni, Arvind G.
    Shah, Siddharth M.
    INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (05) : 470 - 472
  • [33] Unilateral C1 Lateral Mass and C2 Pedicle Screw Fixation for Atlantoaxial Instability in Rheumatoid Arthritis Patients : Comparison with the Bilateral Method
    Paik, Seung-Chull
    Chun, Hyoung-Joon
    Bak, Koang Hum
    Ryu, Jeil
    Choi, Kyu-Sun
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 57 (06) : 460 - 464
  • [34] C1-C2 intra-articular screw fixation for atlantoaxial posterior stabilization
    Tokuhashi, Y
    Matsuzaki, H
    Shirasaki, Y
    Tateishi, T
    SPINE, 2000, 25 (03) : 337 - 341
  • [35] Comparison of Outcomes Between C1-C2 Screw-Hook Fixation and C1-C2 Screw-Rod Fixation for Treating Reducible Atlantoaxial Dislocation
    Ni, Bin
    Zhao, Wenlong
    Guo, Qunfeng
    Zhang, Mei
    Chen, Jinshui
    Guo, Xiang
    Lu, Xuhua
    Xie, Ning
    SPINE, 2017, 42 (20) : 1587 - 1593
  • [36] Endovascular treatment of a vertebral artery pseudoaneurysm following posterior C1-C2 transarticular screw fixation
    Méndez, JC
    González-Llanos, F
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (01) : 107 - 109
  • [37] C1-C2 Pedicle Screw Fixation for Treatment of Old Odontoid Fractures
    Qi, Lei
    Li, Mu
    Zhang, Shuai
    Si, Haipeng
    Xue, Jingsong
    ORTHOPEDICS, 2015, 38 (02) : 94 - 100
  • [38] Safety Issues and Neurological Improvement following C1-C2 Fusion using C1 Lateral Mass and C2 Pedicle Screw in Atlantoaxial Instability
    Kwan, M. K.
    Chan, C. Y. W.
    Kwan, T. C. C.
    Gashi, Y. N.
    Saw, L. B.
    MALAYSIAN ORTHOPAEDIC JOURNAL, 2010, 4 (02) : 17 - 22
  • [39] Management of Unstable C1 Fractures Involving the Lateral Mass: Posterior C1-C2 Screw-Rod Fixation and Fusion
    Zou, Xiaobao
    Yang, Haozhi
    Deng, Chenfu
    Chen, Junlin
    Ma, Rencai
    Ma, Xiangyang
    Xia, Hong
    MEDICAL SCIENCE MONITOR, 2023, 29 : e938600
  • [40] Posterior C1-C2 screw-rod fixation and autograft fusion for the treatment of os odontoideum with C1-C2 instability
    Huang, Da-Geng
    Wang, Tao
    Hao, Ding-Jun
    He, Bao-Rong
    Liu, Tuan-Jiang
    Ma, Xiao-Wen
    Yu, Cheng-Cheng
    Feng, Hang
    Zhao, Song-Chum
    Hui, Hua
    CLINICAL NEUROLOGY AND NEUROSURGERY, 2017, 163 : 71 - 75