Audit of bone marrow aspirates and trephine biopsies in multiple myeloma - a single centre study

被引:12
|
作者
Charles, KS
Winfield, DA
Angel, C
Goepel, J
机构
[1] Port Of Spain Gen Hosp, Dept Haematol, Port Of Spain, Trinidad Tobago
[2] Royal Hallamshire Hosp, Dept Haematol, Sheffield S10 2JF, S Yorkshire, England
[3] Royal Hallamshire Hosp, Dept Pathol, Sheffield, S Yorkshire, England
来源
CLINICAL AND LABORATORY HAEMATOLOGY | 2004年 / 26卷 / 06期
关键词
bone marrow; trephine biopsies; aspirates; myeloma;
D O I
10.1111/j.1365-2257.2004.00646.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared 79 simultaneous marrow aspirates and trephine biopsies, from multiple myeloma patients for sensitivity. concordance. quality and clinical relevance. A total of 60 examinations had been performed for initial diagnosis. i.e. in cases of suspected myeloma and 19 at follow-up. Of which. 45 (57%) of trephine biopsies were less than 1.6 cm before processing and 33 (42%) were crushed and/or fragmented. Overall. only 19/79 (24%) of trephine biopsy specimens were of at least 1.6 cut length prior to processing and not disrupted. On the other hand. 75% of aspirates were particulate and satisfactory. Mean time between receipt of a trephine biopsy specimen and issuance of a histopathological report was 9 days. Although 40% of trephine biopsies yielded information that could not bee reliably obtained from a bone marrow aspirate such information was in all cases clinically irrelevant or obtainable by non-invasive means. In all cases where myeloma was detected in a trephine biopsy it was also detected in a simultaneous bone marrow aspirate. if particulate. However. there were four (5%) cases in which myeloma was detected in such aspirates but not in simultaneously taken trephine biopsies. In cases (n = 19) where repeat aspirates/trephine biopsies were taken for surveillance. concordance was found between reported changes in plasma cell ratio. Our data failed to demonstrate any added benefit from routinely performing trephine biopsies after a particulate specimen had been aspirated for the diagnosis or surveillance of myeloma. Furthermore, they suggest that particulate aspirates may be at least as sensitive as trephine biopsies for detecting myeloma.
引用
收藏
页码:403 / 406
页数:4
相关论文
共 50 条
  • [21] Ancillary techniques in bone marrow pathology: molecular diagnostics on bone marrow trephine biopsies
    Fend, F
    Bock, O
    Kremer, M
    Specht, K
    Quintanilla-Martinez, L
    VIRCHOWS ARCHIV, 2005, 447 (06) : 909 - 919
  • [22] Ancillary techniques in bone marrow pathology: molecular diagnostics on bone marrow trephine biopsies
    Falko Fend
    Oliver Bock
    Markus Kremer
    Katja Specht
    Leticia Quintanilla-Martinez
    Virchows Archiv, 2005, 447 : 909 - 919
  • [23] The additional role of bone marrow particle sections ('clot sections') in confirming marrow involvement by multiple myeloma: a single centre study
    Mathur, K.
    Soutar, R.
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2010, 32 (01) : E179 - E180
  • [24] Trained clinical nurse specialists proficiently obtain bone marrow aspirates and trephine biopsies in a nearly painless procedure-a prospective evaluation study
    Naegele, M.
    Leppla, L.
    Kiote-Schmidt, C.
    Ihorst, G.
    Rebafka, A.
    Koller, A.
    May, A. M.
    Hasemann, M.
    Duyster, J.
    Waesch, R.
    Engelhardt, M.
    ANNALS OF HEMATOLOGY, 2015, 94 (09) : 1577 - 1584
  • [25] Detection of neuroblastoma in the bone marrow: Biopsies versus aspirates
    Aronica, P
    Pirrotta, V
    Yunis, E
    Penchansky, L
    LABORATORY INVESTIGATION, 1997, 76 (01) : 3 - 3
  • [26] DETECTION OF BONE-MARROW INVASION BY NEURO-BLASTOMA IS IMPROVED BY SAMPLING AT 2 SITES WITH BOTH ASPIRATES AND TREPHINE BIOPSIES
    FRANKLIN, IM
    PRITCHARD, J
    JOURNAL OF CLINICAL PATHOLOGY, 1983, 36 (11) : 1215 - 1218
  • [27] ACUTE MYELOFIBROSIS AND MEGAKARIOBLASTIC LEUKEMIA - AN IMMUNOHISTOCHEMICAL STUDY ON BONE-MARROW TREPHINE BIOPSIES
    NAVONE, R
    PICH, A
    AZZONI, L
    PATHOLOGY RESEARCH AND PRACTICE, 1987, 182 (04) : 532 - 532
  • [28] Flow cytometric detection of aneuploid multiple myeloma clones in bone marrow aspirates.
    Kleine, HD
    Buthmann, U
    Freund, M
    BLOOD, 2001, 98 (11) : 299B - 299B
  • [29] Circulating tumour DNA sequence analysis as an alternative to multiple myeloma bone marrow aspirates
    Olena Kis
    Rayan Kaedbey
    Signy Chow
    Arnavaz Danesh
    Mark Dowar
    Tiantian Li
    Zhihua Li
    Jessica Liu
    Mark Mansour
    Esther Masih-Khan
    Tong Zhang
    Scott V. Bratman
    Amit M. Oza
    Suzanne Kamel-Reid
    Suzanne Trudel
    Trevor J. Pugh
    Nature Communications, 8
  • [30] BONE MARROW ASPIRATION SIGNIFICANTLY UNDERESTIMATES THE BURDEN OF DISEASE IN MULTIPLE MYELOMA AT DIAGNOSIS AND FOLLOW UP COMPARED WITH THE BONE MARROW TREPHINE
    Thomas, A.
    Hughes, D. A.
    Mehta, A.
    Wechalekar, A.
    McNamara, C.
    HAEMATOLOGICA, 2014, 99 : 380 - 381