Optic Disc Morphology in Open-Angle Glaucoma Compared with Anterior Ischemic Optic Neuropathies

被引:56
|
作者
Danesh-Meyer, Helen V. [1 ]
Boland, Michael V. [2 ]
Savino, Peter J. [3 ]
Miller, Neil R. [2 ]
Subramanian, Prem S. [2 ]
Girkin, Christopher A. [4 ]
Quigley, Harry A. [2 ]
机构
[1] Univ Auckland, Dept Ophthalmol, New Zealand Natl Eye Ctr, Auckland 1020, New Zealand
[2] Johns Hopkins Univ, Wilmer Ophthalmol Inst, Baltimore, MD 21218 USA
[3] Thomas Jefferson Med Sch, Wilmer Eye Inst, Philadelphia, PA USA
[4] Univ Alabama Birmingham, Dept Ophthalmol, Birmingham, AL 35294 USA
基金
美国国家卫生研究院;
关键词
FIBER LAYER THICKNESS; LAMINA-CRIBROSA; VISUAL-FIELD; NERVE HEAD; PREVALENCE; TOPOGRAPHY; SIZE; EYES;
D O I
10.1167/iovs.09-3492
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To compare optic disc topography performed by confocal laser ophthalmoscopy in eyes with nonarteritic anterior ischemic optic neuropathy (NAION), arteritic anterior ischemic optic neuropathy (AAION), and open-angle glaucoma (OAG), adjusting for the amount of retinal ganglion cell (RGC) loss, as measured by nerve fiber layer (NFL) thickness and average visual field loss. METHODS. At four referral centers, patients who met specific diagnostic criteria for OAG (103 persons, 152 eyes), NAION (53 persons, 57 eyes), or AAION (18 persons, 20 eyes) underwent Heidelberg Retinal Tomography (HRT; Heidelberg Engineering, Heidelberg, Germany), Stratus Optical Coherence Tomography (OCT; Carl Zeiss Meditec, Inc., Dublin, CA), and Humphrey visual field testing (HFA; Carl Zeiss Meditec, Inc.). HRT parameters were compared in univariate and multivariate models, accounting for degree of RGC loss by either OCT NFL thickness or visual field mean deviation (MD). Acute AION occurred at least 6 weeks before testing. RESULTS. After adjustment for degree of injury according to either MD or mean NFL thickness, all HRT parameters were significantly different between OAG and both NAION and AAION. With similar damage, OAG eyes had larger, deeper cups; smaller rims; more cup volume; and less rim volume (all P <= 0.001). There were differences in disc topography between NAION and AAION, but they were not consistent for both measures of damage. Disc area and MD were also significantly associated with many HRT parameters. NFL thickness was greater at the same MD for both AAION and NAION compared with OAG. CONCLUSIONS. NAION and AAION cause loss of RGCs, but have significantly different disc topography compared with OAG at a given level of RGC loss. (Invest Ophthalmol Vis Sci. 2010; 51: 2003-2010) DOI:10.1167/iovs.09-3492
引用
收藏
页码:2003 / 2010
页数:8
相关论文
共 50 条
  • [21] Optic disc topography and peripapillary retinal nerve fiber layer thickness in nonarteritic ischemic optic neuropathy and open-angle glaucoma
    Saito, Hitomi
    Tomidokoro, Atsuo
    Sugimoto, Eiichiro
    Aihara, Makoto
    Tomita, Goji
    Fujie, Kazutaka
    Wakakura, Masato
    Araie, Makoto
    OPHTHALMOLOGY, 2006, 113 (08) : 1340 - 1344
  • [23] Open-Angle Glaucoma and Ischemic Optic Neuropathy with Injectable Testosterone Use
    Dahshan, Deena
    Verma, Vishal
    Goel, Manik
    OPHTHALMOLOGY GLAUCOMA, 2022, 5 (02): : 244 - 245
  • [24] Microvascular and structural alterations in the optic nerve head of advanced primary open-angle glaucoma compared with atrophic non-arteritic anterior ischemic optic neuropathy
    Hondur, Gozde
    Sen, Emine
    Budakoglu, Ozlem
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2021, 259 (07) : 1945 - 1953
  • [25] Microvascular and structural alterations in the optic nerve head of advanced primary open-angle glaucoma compared with atrophic non-arteritic anterior ischemic optic neuropathy
    Gozde Hondur
    Emine Sen
    Ozlem Budakoglu
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2021, 259 : 1945 - 1953
  • [26] 3-DIMENSIONAL EVALUATION OF OPTIC DISC PALLOR IN OPEN-ANGLE GLAUCOMA
    SAGATIES, MJ
    SCHWARTZ, B
    ACTA OPHTHALMOLOGICA, 1993, 71 (03): : 308 - 314
  • [28] Rate of optic disc cup progression in treated primary open-angle glaucoma
    Kwon, YH
    Kim, YI
    Pereira, MLM
    Montague, PR
    Zimmerman, MB
    Alward, WLM
    JOURNAL OF GLAUCOMA, 2003, 12 (05) : 409 - 416
  • [29] Fluorescein leakage of the optic disc: time course in primary open-angle glaucoma
    Plange, Niklas
    Kaup, Marion
    Doehmen, Benjamin
    Remky, Andreas
    Arend, Kay Oliver
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2010, 30 (03) : 315 - 320
  • [30] Different types of optic disc shape in patients with advanced open-angle glaucoma
    Nakazawa, Toru
    Fuse, Nobuo
    Omodaka, Kazuko
    Aizawa, Naoko
    Kuwahara, Souichiro
    Nishida, Kohji
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (04) : 291 - 295