Reducing CO2 emissions by curtailing renewables: Examples from optimal power system operation

被引:24
|
作者
Morales-Espana, German [1 ]
Nycander, Elis [2 ]
Sijm, Jos [1 ]
机构
[1] TNO Energy Transit, Delft, Netherlands
[2] KTH Royal Inst Technol, Stockholm, Sweden
关键词
Variable renewable energy; Curtailment; CO2; emissions; Economic dispatch; Unit commitment; Reserves; ROBUST UNIT COMMITMENT; LARGE-SCALE INTEGRATION; WIND POWER; ENERGY; ELECTRICITY; GENERATION; MARKET; SECURITY; POLICIES; SAVINGS;
D O I
10.1016/j.eneco.2021.105277
中图分类号
F [经济];
学科分类号
02 ;
摘要
To lower CO2 emissions, policy makers want to integrate as much variable renewable energy (VRE) as possible into power systems. This has been translated into targets for VRE as a share of total electricity generation and policies that aim to maximize the use of electricity available from VRE sources. However, in this paper we demonstrate that it is a misconception that maximizing VRE production always lowers CO2 emissions. In fact there are many constraints in power system operation that can lead to situations when curtailing VRE reduces both costs and CO2 emissions. In this paper we identify these situations and constraints, and illustrate them with several examples. The examples show how different constraints from optimal power system operation, using economic dispatch (ED) and unit commitment (UC), can combine to create the seemingly paradoxical result that curtailing VRE reduces both costs and CO2 emissions. Broadly defined these situations can occur 1) due to network constraints which create the need for inefficient redispatch actions if VRE is not curtailed, 2) due to increased need for ramp capability and cycling from other units, and 3) due to reserve/security requirements which can be satisfied more efficiently by allowing VRE curtailment. To achieve the most economical and efficient operation of power systems, instead of VRE curtailment being seen as a measure of last resort to preserve system security, VRE should always be optimally dispatched through markets based on its true cost, thus maximizing the value of VRE to the system rather than its output. (C) 2021 The Authors. Published by Elsevier B.V.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] THE COST OF REDUCING CO2 EMISSIONS - A COMPARISON OF THE GERMAN AND UK POWER SECTORS
    MORRISON, MB
    TENBRINK, P
    ENERGY POLICY, 1993, 21 (03) : 284 - 295
  • [32] Saving energy and reducing CO2 emissions
    Quinn, B
    POLLUTION ENGINEERING, 1999, 31 (05) : 33 - 33
  • [33] Cost of reducing CO2 emissions in Japan
    Kuroda, M
    Nomura, K
    GLOBAL WARMING AND THE ASIAN PACIFIC, 2003, : 153 - 167
  • [34] Development of a system of CO2 emissions trading for power generation
    Dekkers, C
    Scholtz, A
    GREENHOUSE GAS CONTROL TECHNOLOGIES, 2001, : 1115 - 1120
  • [35] Minimization of life cycle CO2 emissions in the operation of a steam and power plant
    Eliceche, Ana M.
    Martinez, Pablo E.
    17TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2007, 24 : 1181 - 1186
  • [36] MODELLING CO2 EMISSIONS IMPACTS ON CROATIAN POWER SYSTEM
    Pasicko, Robert
    Robic, Slavica
    Tomsic, Zeljko
    THERMAL SCIENCE, 2010, 14 (03): : 655 - 669
  • [37] Impact of power consumption and power saving for GI endoscopy (power on study) on reducing CO2 emissions
    Fichtl, Anna
    Tacheva, Veronika
    Sturm, Niklas
    Hamesch, Karim
    Wichmann, Doerte
    Mayer, Benjamin
    Mueller, Martin
    Wagner, Martin
    Seufferlein, Thomas
    Walter, Benjamin M.
    GUT, 2024, 73 (06) : 892 - 896
  • [38] Microbial CO2 fixation and biotechnology in reducing industrial CO2 emissions
    Sachin Kajla
    Ritu Kumari
    Gurpreet Kaur Nagi
    Archives of Microbiology, 2022, 204
  • [39] Microbial CO2 fixation and biotechnology in reducing industrial CO2 emissions
    Kajla, Sachin
    Kumari, Ritu
    Nagi, Gurpreet Kaur
    ARCHIVES OF MICROBIOLOGY, 2022, 204 (02)
  • [40] CO2 REMOVAL IN COMPETITION WITH OTHER OPTIONS FOR REDUCING CO2 EMISSIONS
    OKKEN, PA
    LAKO, P
    GERBERS, D
    KRAM, T
    YBEMA, JR
    ENERGY CONVERSION AND MANAGEMENT, 1992, 33 (5-8) : 737 - 745