Histologic evolution of high-intensity focused ultrasound in rabbit muscle

被引:17
|
作者
Solomon, SB
Nicol, TL
Chan, DY
Fjield, T
Fried, N
Kavoussi, LR
机构
[1] Johns Hopkins Sch Med, Dept Radiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Sch Med, Dept Pathol, Baltimore, MD 21287 USA
[3] Johns Hopkins Sch Med, Dept Urol, Baltimore, MD 21287 USA
[4] Transurg Inc, Setakuet, NY 11733 USA
关键词
high-intensity focused ultrasound; histology; ablation; heat; muscle;
D O I
10.1097/01.RLI.0000066421.79958.96
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: The purpose of this study was to examine the histologic evolution over time of rabbit skeletal muscle thermally ablated with high-intensity focused ultrasound. The objectives included determining the extent and focality of damage created by this noninvasive, transcutaneous ablative technology. Methods: Transcutaneous, thermal ablation with an external focused ultrasound transducer was applied to the paraspinous muscles of 19 rabbits. At varying times, up to 100 days after therapy, single sonications were examined histologically. Results: Initially, only subtle staining changes were identified within lesions. In the chronic phase (day 51-100), the muscle was replaced or infiltrated by variable amounts of scar and fat similar to degenerative muscle disorders. Histologic changes were limited to the tissue within the intensity focus of the transducer and were not seen in intervening tissues. Discussion: The current study took a systematic approach to study the long term, in vivo histologic effects of single HIFU lesions in a nonregenerative tissue. This experience in muscle tissue will provide a basis for understanding ultrasound effects for clinical applications such as treatment of uterine fibroids, cardiac tissue, and sarcomas.
引用
收藏
页码:293 / 301
页数:9
相关论文
共 50 条
  • [21] Selective reduction of multifetal pregnancy using high-intensity focused ultrasound in the rabbit model
    Paek, B
    Foley, J
    Zderic, V
    Starr, F
    Shields, LE
    Vaezy, S
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2005, 26 (03) : 267 - 270
  • [22] High-Intensity Focused Ultrasound (HIFU) for Dissolution of Clots in a Rabbit Model of Embolic Stroke
    Burgess, Alison
    Huang, Yuexi
    Waspe, Adam C.
    Ganguly, Milan
    Goertz, David E.
    Hynynen, Kullervo
    PLOS ONE, 2012, 7 (08):
  • [23] High-intensity focused ultrasound in ovarian cancer xenografts
    Wu, Rong
    Hu, Bing
    Jiang, Li-Xin
    Hung, Ying
    Kuang, Sheng-Li
    Zhang, Bulin
    ADVANCES IN THERAPY, 2008, 25 (08) : 810 - 819
  • [24] URETHRAL STRICTURE AFTER HIGH-INTENSITY FOCUSED ULTRASOUND
    Hofmann, Martin
    Furr, James
    Gelman, Joel
    JOURNAL OF UROLOGY, 2019, 201 (04): : E974 - E975
  • [25] Parameter estimation in high-intensity focused ultrasound therapy
    de los Rios Cardenas, Laura
    Bermeo Varon, Leonardo A.
    de Albuquerque Pereira, Wagner Coelho
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING, 2022, 38 (05)
  • [26] Machining of Aluminium with MHz High-Intensity Focused Ultrasound
    Pudas, Topi
    Hyvonen, Jere
    Holmstrom, Axi
    Sillanpaa, Tom
    Lassila, Petri
    Makinen, Joni
    Kuronen, Antti
    Kotiaho, Tapio
    Salmi, Ari
    Haeggstrom, Edward
    2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS), 2022,
  • [27] High-intensity focused ultrasound therapy: An overview for radiologists
    Kim, Young-Sun
    Kim, Hyunchul
    Choi, Min Joo
    Lim, Hyo Keun
    Choi, Dongil
    KOREAN JOURNAL OF RADIOLOGY, 2008, 9 (04) : 291 - 302
  • [28] High-intensity focused ultrasound in the treatment of solid tumours
    Kennedy, JE
    NATURE REVIEWS CANCER, 2005, 5 (04) : 321 - 327
  • [29] Gaussian representation of high-intensity focused ultrasound beams
    Soneson, Joshua E.
    Myers, Matthew R.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2007, 122 (05): : 2526 - 2531
  • [30] Noninvasive Thermometry in High-Intensity Focused Ultrasound Ablation
    Zhou, Yufeng
    ULTRASOUND QUARTERLY, 2017, 33 (04) : 253 - 260