A solar dynamic (SD) space power system has been under test at the NASA Lewis Research Center since 1994. The SD Ground Test Demonstration (GTD) system includes a solar concentrator, heat receiver with thermal energy storage, Brayton power conversion unit, and radiator installed in a thermal-vacuum chamber with a solar simulator. The Brayton unit has been operated with two different turboalternator-compressor (TAC) assemblies, one which included a Rice-Lundell alternator and another which incorporated a permanent magnet (PM) alternator. The Rice alternator was part of the mini-Brayton rotating unit, designed and built during the 1970's and refurbished for the GTD. The PM TAC was a development unit from the Joint US/Russian SD Flight Project. This paper highlights the operational differences (and similarities) between the Rice and PM TAC configurations including a comparative evaluation of startup characteristics and operating performance. The two alternator configurations were tested under similar thermal conditions, as an interchangeable component within the SD system. The electrical characteristics of the two units, however, dictated the use of significantly different power conditioning and control strategies. The electrical control architectures are described and compared. Test data are presented on TAC startup and system operating performance for both configurations.
引用
收藏
页码:454 / 459
页数:6
相关论文
共 50 条
  • [1] Supercritical CO2 Mixtures for Brayton Power Cycles Complex Configurations with Concentrating Solar Power
    Valencia-Chapi, Robert
    Tafur-Escanta, Paul
    Coco-Enriquez, Luis
    Munoz-Anton, Javier
    SOLARPACES 2020 - 26TH INTERNATIONAL CONFERENCE ON CONCENTRATING SOLAR POWER AND CHEMICAL ENERGY SYSTEMS, 2022, 2445
  • [2] OPTIMIZATION AND DEVELOPMENT OF SOLAR BRAYTON-CYCLE POWER SYSTEM
    PIETSCH, A
    MECHANICAL ENGINEERING, 1965, 87 (07) : 58 - &
  • [5] Experimental study in a compound parabolic solar concentrator with different configurations of thermal energy storage system
    Christopher, Sathiya Satchi
    Ahmed, Kalilur Rahiman Arshad
    Shyam, Ashokkumar
    Iniyan, Selvarasan
    INTERNATIONAL JOURNAL OF GREEN ENERGY, 2024, 21 (01) : 54 - 63
  • [6] Comparison of different configurations of the solar and wind power supply system with energy storage using Matlab
    Gluchy, Damian
    Jarmuda, Tomasz
    Tomczewski, Andrzej
    COMPUTER APPLICATIONS IN ELECTRICAL ENGINEERING (ZKWE'2018), 2018, 19
  • [7] An experimental comparative study on different configurations of basin solar still
    Ensafisoroor, Hamed
    Khamooshi, Mehrdad
    Egelioglu, Fuat
    Parham, Kiyan
    DESALINATION AND WATER TREATMENT, 2016, 57 (05) : 1901 - 1916
  • [8] Thermodynamic Analysis of a Solar Assisted Combined Cooling, Heating and Power System with Different Cooling Cycle Configurations
    V. Ravindra
    M. Ramgopal
    INAE Letters, 2018, 3 (2): : 107 - 113
  • [9] Experimental thermal performance evaluation of different configurations of Copenhagen solar cooker
    Apaolaza-Pagoaga, Xabier
    Carrillo-Andrés, Antonio
    Rodrigues Ruivo, Celestino
    Renewable Energy, 2022, 184 : 604 - 618
  • [10] Experimental thermal performance evaluation of different configurations of Copenhagen solar cooker
    Apaolaza-Pagoaga, Xabier
    Carrillo-Andres, Antonio
    Ruivo, Celestino Rodrigues
    RENEWABLE ENERGY, 2022, 184 : 604 - 618