Stimulated single-fiber electromyography in the rat

被引:0
|
作者
Lin, TS [1 ]
Cheng, TJ [1 ]
机构
[1] Natl Cheng Kung Univ Hosp, Dept Neurol, Tainan, Taiwan
关键词
single-fiber electromyography; jitter; safety factor; animal study; rat;
D O I
10.1002/(SICI)1097-4598(199804)21:4<482::AID-MUS6>3.0.CO;2-5
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
We constructed an animal model of stimulated single-fiber electromyography (SFEMG) by testing Wistar rats under anesthesia. Stimuli of 1 Hz were applied to the sciatic nerve through an insulated monopolar needle electrode. Single-fiber action potentials were acquired from the gastrocnemius muscle. Jitter was assessed by the mean consecutive difference (MCD). Eighty-seven fibers were obtained from 12 rats. Their MCDs ranged from 2 to 72 mu s (17.7 +/- 13.4). Seven of these values were less than or equal to 5 mu s, and three exceeded 50 mu s. Neuromuscular blocking agents injected into some of the rats induced considerable increases in jitter and blocking. A rat with one fiber with an MCD less than 5 us also received an injection of curare. The jitter showed the same pattern of increment, evidence that the small jitter was not attributable to direct muscle stimulation. These results show that SFEMG can be used on rats. In addition, jitter reflects the changes in motor end-plate function. The findings also suggest the presence of an extremely high safety factor in rat neuromuscular junctions. (C) 1998 John Wiley & Sons, Inc.
引用
收藏
页码:482 / 489
页数:8
相关论文
共 50 条
  • [31] RECORDING OF SINGLE-FIBER ELECTROMYOGRAPHY IN PATIENTS WITH PERIPHERAL FACIAL PALSY
    TAKEDA, K
    TOJIMA, H
    AOYAGI, M
    KOIKE, Y
    ACTA OTO-LARYNGOLOGICA, 1994, : 156 - 160
  • [32] Single-fiber electromyography in amyotrophic lateral sclerosis and cervical spondylosis
    Liu, Mingsheng
    Cui, Liying
    Guan, Yuzhou
    Li, Benhong
    Du, Hua
    MUSCLE & NERVE, 2013, 48 (01) : 137 - 139
  • [33] Near-tendon single-fiber electromyography in patients with myopathy
    Sirin, Nermin Gorkem
    Mehdikhanova, Lala
    Sirinocak, Pinar Bekdik
    Arkali, Nuran Burcu
    Baslo, Mehmet Baris
    Orhan, Elif Kocasoy
    NEUROPHYSIOLOGIE CLINIQUE-CLINICAL NEUROPHYSIOLOGY, 2022, 52 (02): : 174 - 177
  • [34] Sensitivity and specificity of the single-fiber electromyography in ocular myasthenia gravis
    Arnaudo, E
    Castillo, I
    Sharma, M
    Bird, SJ
    Savino, PJ
    ANNALS OF NEUROLOGY, 2002, 52 (03) : S50 - S50
  • [35] SINGLE-FIBER ELECTROMYOGRAPHY IN EXPERIMENTAL AUTOIMMUNE MYASTHENIA-GRAVIS
    VERSCHUUREN, JJGM
    SPAANS, F
    DEBAETS, MH
    MUSCLE & NERVE, 1990, 13 (06) : 485 - 492
  • [36] SINGLE-FIBER ELECTROMYOGRAPHY JITTERMETER FROM AN INEXPENSIVE HOME COMPUTER
    WIECHERS, D
    FATEHI, M
    MUSCLE & NERVE, 1981, 4 (05) : 442 - 442
  • [37] DIAGNOSTIC UTILITY OF STIMULATED SINGLE-FIBER ELECTROMYOGRAPHY OF THE ORBICULAR'S OCULI MUSCLE IN PATIENTS WITH SUSPECTED OCULAR MYASTHENIA
    Mercelis, Rudy
    Merckaert, Virginie
    MUSCLE & NERVE, 2011, 43 (02) : 168 - 170
  • [38] Optimum trace count necessary for jitter calculation in single-fiber electromyography
    Baslo, MB
    Yalinay, P
    Yildiz, N
    Ertas, M
    ACTA NEUROLOGICA SCANDINAVICA, 2003, 108 (04): : 262 - 266
  • [39] SINGLE-FIBER ELECTROMYOGRAPHY OF EXTRAOCULAR-MUSCLES IN MYASTHENIA-GRAVIS
    UYAMA, J
    MIMURA, O
    IKEDA, N
    SHIMOOKU, M
    NEURO-OPHTHALMOLOGY, 1993, 13 (05) : 253 - 261
  • [40] Concentric-needle single-fiber electromyography for the diagnosis of myasthenia gravis
    Benatar, Michael
    Hammad, Mustafa
    Doss-Riney, Heidi
    MUSCLE & NERVE, 2006, 34 (02) : 163 - 168