Evaluation of four commercially available rapid serologic tests for diagnosis of leptospirosis

被引:171
|
作者
Bajani, MD
Ashford, DA
Bragg, SL
Woods, CW
Aye, T
Spiegel, RA
Plikaytis, BD
Perkins, BA
Phelan, M
Levett, PN
Weyant, RS
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Infect Dis, Meningitis & Special Pathogens Branch, Div Bacterial & Mycot Dis, Atlanta, GA 30333 USA
[2] Ctr Dis Control & Prevent, Natl Ctr Infect Dis, Biostat & Informat Management Branch, Div Bacterial & Mycot Dis, Atlanta, GA 30333 USA
关键词
D O I
10.1128/JCM.41.2.803-809.2003
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Four rapid tests for the serologic diagnosis of leptospirosis were evaluated, and the performance of each was compared with that of the current standard, the microscopic agglutination test (MAT). The four rapid tests were a microplate immunoglobulin M (IgM)-enzyme-linked immunosorbent assay (ELISA), an indirect hemagglutination assay (IRA), an IgM dipstick assay (LDS), and an IgM dot-ELISA dipstick test (DST). A panel of 276 sera from 133 cases of leptospirosis from four different geographic locations was tested as well as 642 sera from normal individuals or individuals with other infectious or autoimmune diseases. Acute-phase sera from cases (n = 148) were collected less than or equal to14 days (median = 6.0) after the onset of symptoms, and convalescent-phase sera (n = 128) were collected greater than or equal to15 days after onset (median = 29.1). By a traditional method (two-by-two contingency table), the sensitivities for detection of leptospirosis cases were 93.2% by LDS, 92.5% by DST, 86.5% by ELISA, and 79.0% by IRA. Specificity was 98.8% by DST, 97% by ELISA and MAT, 95.8% by IRA, and 89.6% by LDS. With a latent class analysis (LCA) model that included all the rapid tests and the clinical case definition, sensitivity was 95.5% by DST, 94.5% by LDS, 89.9% by ELISA, and 81.1% by IRA. The sensitivity and specificity estimated by the traditional methods were quite close to the LCA estimates. However, LCA allowed estimation of the sensitivity of the MAT (98.2%), which traditional methods do not allow. For acute-phase sera, sensitivity was 52.7% by LDS, 50.0% by DST, 48.7% by MAT and ELISA, and 38.5% by IRA. The sensitivity for convalescent-phase sera was 93.8% by MAT, 84.4% by DST, 83.6% by LDS, 75.0% by ELISA, and 67.2% by IHA. A good overall correlation with the MAT was obtained for each of the assays, with the highest concordance being with the DST (kappa value, 0.85; 95% confidence interval [CI], 0.8 to 0.90). The best correlation was between ELISA and DST (kappa value, 0.86; 95% CI, 0.81 to 0.91). False-positive LDS results were frequent (greater than or equal to20%) in sera from individuals with Epstein-Barr virus, human immunodeficiency virus, and periodontal disease and from healthy volunteers. The ease of use and significantly high sensitivity and specificity of DST and ELISA make these good choices for diagnostic testing.
引用
收藏
页码:803 / 809
页数:7
相关论文
共 50 条
  • [31] Laboratory Evaluation of a Commercially Available Rapid Syphilis Test
    Pereira, Lara E.
    McCormick, Joshua
    Dorji, Tandin
    Kang, Joseph
    Sun, Yongcheng
    Shukla, Mayur
    Hopkins, Andre
    Deutsch, John
    Kersh, Ellen N.
    Bernstein, Kyle
    Fakile, Yetunde F.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2018, 56 (10)
  • [32] Principles of commercially available Tests for the Diagnosis of COVID-19
    Siekmeier, Rudiger
    Hannig, Jurgen
    Grammer, Tanja
    Marz, Winfried
    WIENER KLINISCHE WOCHENSCHRIFT, 2021, 133 (SUPPL 5) : 185 - 185
  • [33] AVAILABLE RUBELLA SEROLOGIC TESTS
    HERRMANN, KL
    REVIEWS OF INFECTIOUS DISEASES, 1985, 7 : S108 - S112
  • [34] Evaluation of four commercially available extended-spectrum beta-lactamase phenotypic confirmation tests
    Linscott, AJ
    Brown, WJ
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (03) : 1081 - 1085
  • [35] Reactivity and sensitivity of commercially available influenza rapid diagnostic tests in Japan
    Yuko Sakai-Tagawa
    Seiya Yamayoshi
    Chiharu Kawakami
    Mai Q. Le
    Yuko Uchida
    Takehiko Saito
    Chairul A. Nidom
    Ira Humaira
    Kathy Toohey-Kurth
    Abdel-Satar Arafa
    Ming-Tsan Liu
    Yuelong Shu
    Yoshihiro Kawaoka
    Scientific Reports, 7
  • [36] Reactivity and sensitivity of commercially available influenza rapid diagnostic tests in Japan
    Sakai-Tagawa, Yuko
    Yamayoshi, Seiya
    Kawakami, Chiharu
    Le, Mai Q.
    Uchida, Yuko
    Saito, Takehiko
    Nidom, Chairul A.
    Humaira, Ira
    Toohey-Kurth, Kathy
    Arafa, Abdel-Satar
    Liu, Ming-Tsan
    Shu, Yuelong
    Kawaoka, Yoshihiro
    SCIENTIFIC REPORTS, 2017, 7
  • [37] Field Evaluation of Four Rapid Tests for Diagnosis of HIV Infection in Panama
    Juarez, Sandra I.
    Nunez, Aurelio E.
    Aranda, Margginna M.
    Mojica, Dalis
    Kim, Andrea A.
    Parekh, Bharat
    JOURNAL OF CLINICAL MICROBIOLOGY, 2016, 54 (04) : 1127 - 1129
  • [38] Evaluation of four rapid diagnostic tests for the diagnosis of Plasmodium vivax in Korea
    Kim, Kyung Hee
    Jang, Jin Woo
    Woo, Mi Kyung
    Oh, Jun Seo
    Han, Eun Taek
    Lee, Won Ja
    An, Seong Soo A.
    Lim, Chae Seung
    TROPICAL MEDICINE & INTERNATIONAL HEALTH, 2011, 16 (11) : 1427 - 1431
  • [39] Rapid tests for diagnosis of leptospirosis: Current tools and emerging technologies
    Picardeau, Mathieu
    Bertherat, Eric
    Jancloes, Michel
    Skouloudis, Andreas N.
    Durski, Kara
    Hartskeerl, Rudy A.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2014, 78 (01) : 1 - 8
  • [40] Flow evaluation of four commercially available endodontic sealer.
    Bassi, MA
    Menduno, S
    Gambarini, G
    Goracci, G
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B239 - B239