Design and Implementation of a Real-time Monitoring Platform for Optimal Sepsis Care in an Emergency Department: Observational Cohort Study

被引:2
|
作者
Lee, Andy Hung-Yi [1 ]
Aaronson, Emily [1 ]
Hibbert, Kathryn A. [2 ]
Flynn, Micah H. [3 ]
Rutkey, Hayley [3 ]
Mort, Elizabeth [2 ]
Sonis, Jonathan D. [1 ]
Safavi, Kyan C. [3 ]
机构
[1] Massachusetts Gen Hosp, Dept Emergency Med, 55 Fruit St, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Med, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
关键词
electronic monitoring platform; sepsis; quality improvement; ALERT;
D O I
10.2196/26946
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
Background: Sepsis is the leading cause of death in US hospitals. Compliance with bundled care, specifically serial lactates, blood cultures, and antibiotics, improves outcomes but is often delayed or missed altogether in a busy practice environment. Objective: This study aims to design, implement, and validate a novel monitoring and alerting platform that provides real-time feedback to frontline emergency department (ED) providers regarding adherence to bundled care. Methods: This single-center, prospective, observational study was conducted in three phases: the design and technical development phase to build an initial version of the platform; the pilot phase to test and refine the platform in the clinical setting; and the postpilot rollout phase to fully implement the study intervention. Results: During the design and technical development, study team members and stakeholders identified the criteria for patient inclusion, selected bundle measures from the Center for Medicare and Medicaid Sepsis Core Measure for alerting, and defined alert thresholds, message content, delivery mechanisms, and recipients. Additional refinements were made based on 70 provider survey results during the pilot phase, including removing alerts for vasopressor initiation and modifying text in the pages to facilitate patient identification. During the 48 days of the postpilot rollout phase, 15,770 ED encounters were tracked and 711 patient encounters were included in the active monitoring cohort. In total, 634 pages were sent at a rate of 0.98 per attending physician shift. Overall, 38.3% (272/711) patients had at least one page. The missing bundle elements that triggered alerts included: antibiotics 41.6% (136/327), repeat lactate 32.4% (106/327), blood cultures 20.8% (68/327), and initial lactate 5.2% (17/327). Of the missing Sepsis Core Measures elements for which a page was sent, 38.2% (125/327) were successfully completed on time. Conclusions: A real-time sepsis care monitoring and alerting platform was created for the ED environment. The high proportion of patients with at least one alert suggested the significant potential for such a platform to improve care, whereas the overall number of alerts per clinician suggested a low risk of alarm fatigue. The study intervention warrants a more rigorous evaluation to ensure that the added alerts lead to better outcomes for patients with sepsis.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Quantitative capillary refill time predicts sepsis in patients with suspected infection in the emergency department: an observational study
    Yasufumi, Oi
    Morimura, Naoto
    Shirasawa, Aya
    Honzawa, Hiroshi
    Oyama, Yutaro
    Niida, Shoko
    Abe, Takeru
    Imaki, Shouhei
    Takeuchi, Ichiro
    JOURNAL OF INTENSIVE CARE, 2019, 7 (1)
  • [42] Quantitative capillary refill time predicts sepsis in patients with suspected infection in the emergency department: an observational study
    Oi Yasufumi
    Naoto Morimura
    Aya Shirasawa
    Hiroshi Honzawa
    Yutaro Oyama
    Shoko Niida
    Takeru Abe
    Shouhei Imaki
    Ichiro Takeuchi
    Journal of Intensive Care, 7
  • [43] Accuracy of real-time SNOMED-CT coding by clinicians in an urban tertiary emergency department: A retrospective cohort study
    Jones, Peter
    Ho, Jess
    Burbridge, Hayley
    Hill, Dane
    Khalil, Rana
    Raumati, Inia
    INTERNATIONAL JOURNAL OF MEDICAL INFORMATICS, 2022, 165
  • [44] Using a Real-Time Locating System to Evaluate the Impact of Telemedicine in an Emergency Department During COVID-19: Observational Study
    Patel, Birju
    Vilendrer, Stacie
    Kling, Samantha M. R.
    Brown, Ian
    Ribeira, Ryan
    Eisenberg, Matthew
    Sharp, Christopher
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2021, 23 (07)
  • [45] The Use of a Real-Time COVID-19 Standalone Device in an Emergency Department of a Tertiary Hospital in Singapore: A Pilot Observational Study
    Joshi, Rhea
    Ng, Ee Yang
    Singh, Rahul
    Kuan, Win Sen
    Daruwalla, Zubin Jimmy
    COVID, 2022, 2 (03): : 419 - 432
  • [46] Design and Implementation of Storage System for Real-time Blockchain Network Monitoring System
    Bang, Jiwon
    Choi, Mi-Jung
    2019 20TH ASIA-PACIFIC NETWORK OPERATIONS AND MANAGEMENT SYMPOSIUM (APNOMS), 2019,
  • [47] Design, testing, and implementation of a real-time system for monitoring flow in horizontal wells
    Cormican, Allison
    Devlin, J. F.
    Osorno, T. C.
    Divine, Craig
    JOURNAL OF CONTAMINANT HYDROLOGY, 2021, 238
  • [48] Monitoring real-time junior doctor sentiment from comments on a public social media platform: a retrospective observational study
    Sirkis, Tamir
    Maitland, Stuart
    POSTGRADUATE MEDICAL JOURNAL, 2023, 99 (1171) : 423 - 427
  • [49] Design and implementation of real-time laser power monitoring system in laser ranging
    Wu F.
    Zhai D.
    Li Z.
    Tang R.
    Pi X.
    Li Y.
    Hongwai yu Jiguang Gongcheng/Infrared and Laser Engineering, 2023, 52 (10):
  • [50] A WBAN-based Real-time Electroencephalogram Monitoring System: Design and Implementation
    Chen, Haifeng
    Wu, Wanqing
    Lee, Jungtae