Polvmer-BiI3 composites for high-performance, room-temperature, direct X-ray detectors

被引:7
|
作者
Chaudhari, Ritu [1 ]
Kant, Chhaya Ravi [1 ]
Garg, Alka [2 ]
机构
[1] Indira Gandhi Delhi Tech Univ Women, Dept Appl Sci & Humanities, Delhi 110006, India
[2] Univ Delhi, Gargi Coll, Siri Ft Rd, New Delhi 110049, India
关键词
CRYSTAL;
D O I
10.1557/s43579-022-00185-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Low-energy X-rays have a predominant role in medical diagnostic applications, grown tremendously during recent Covid-19 pandemic times. Synthesis of stable, PMMA/polystyrene-BiI3 composites has been done through a facile, low-cost, dry-tumble mixing technique for direct X-ray detector applications. Comparative analysis of structural, optical, and photocurrent responses upon irradiation with low-energy X-rays (30 and 60 kV) ensue that PS-BiI3 demonstrates high SNR 3300, sensitivity 189 mu C Gy(-1) cm(-3) and fast response time 30 ms, at dose rate 1.68 mGy s(-1), affirming the composite to be prospective candidate for low-energy, room-temperature, direct X-ray detectors under low bias conditions.
引用
收藏
页码:358 / 364
页数:7
相关论文
共 50 条
  • [31] High-performance room-temperature borophene homojunction gas sensor
    Liang, Xinchao
    Wu, Zitong
    Zhao, Zhilin
    Xu, Maoping
    Liu, Yi
    Tai, Guoan
    CHEMICAL ENGINEERING JOURNAL, 2025, 506
  • [32] Directly-deposited blocking filters for high-performance silicon X-ray detectors
    Bautz, M.
    Kissel, S.
    Masterson, R.
    Ryu, K.
    Suntharalingam, V.
    SPACE TELESCOPES AND INSTRUMENTATION 2016: ULTRAVIOLET TO GAMMA RAY, 2016, 9905
  • [33] Room-temperature calorimeter for x-ray free-electron lasers
    Tanaka, T.
    Kato, M.
    Saito, N.
    Tono, K.
    Yabashi, M.
    Ishikawa, T.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2015, 86 (09):
  • [34] A New Room-Temperature Liquid, High-Performance Tricyanate Ester
    Cambrea, Lee R.
    Davis, Matthew C.
    Groshens, Thomas J.
    Guenthner, Andrew J.
    Lamison, Kevin R.
    Mabry, Joseph M.
    JOURNAL OF POLYMER SCIENCE PART A-POLYMER CHEMISTRY, 2010, 48 (20) : 4547 - 4554
  • [35] A high-performance thermoacoustic refrigerator operating in room-temperature range
    Luo, EC
    Huang, Y
    Dai, W
    Zhang, Y
    Wu, ZH
    CHINESE SCIENCE BULLETIN, 2005, 50 (22): : 2662 - 2664
  • [36] High-performance room-temperature THz nanodetectors with a narrowband antenna
    Viti, Leonardo
    Coquillat, Dominique
    Ercolani, Daniele
    Knap, Wojciech
    Sorba, Lucia
    Vitiello, Miriam S.
    TERAHERTZ, RF, MILLIMETER, AND SUBMILLIMETER-WAVE TECHNOLOGY AND APPLICATIONS VII, 2014, 8985
  • [37] Organic Semiconducting Single Crystals as Next Generation of Low-Cost, Room-Temperature Electrical X-ray Detectors
    Fraboni, Beatrice
    Ciavatti, Andrea
    Merlo, Francesco
    Pasquini, Luca
    Cavallini, Anna
    Quaranta, Alberto
    Bonfiglio, Annalisa
    Fraleoni-Morgera, Alessandro
    ADVANCED MATERIALS, 2012, 24 (17) : 2289 - 2293
  • [38] Room-temperature X-ray response of cadmium-zinc-telluride pixel detectors grown by the vertical Bridgman technique
    Abbene, Leonardo
    Principato, Fabio
    Gerardi, Gaetano
    Buttacavoli, Antonino
    Cascio, Donato
    Bettelli, Manuele
    Amade, Nicola Sarzi
    Seller, Paul
    Veale, Matthew C.
    Fox, Oliver
    Sawhney, Kawal
    Zanettini, Silvia
    Tomarchio, Elio
    Zappettini, Andrea
    JOURNAL OF SYNCHROTRON RADIATION, 2020, 27 : 319 - 328
  • [39] PERFORMANCE OF ROOM-TEMPERATURE X-RAY-DETECTORS MADE FROM MERCURIC IODIDE (HGI2) PLATELETS
    BARTON, JB
    DABROWSKI, AJ
    IWANCZYK, JS
    KUSMISS, JH
    RICKER, G
    VALLERGA, J
    WARREN, A
    SQUILLANTE, MR
    LIS, S
    ENTINE, G
    ADVANCES IN X-RAY ANALYSIS, 1982, 25 : 31 - 37
  • [40] Room-Temperature Synthesis of NiCo-Layered Double Hydroxide/MXene Composites for High-Performance Supercapacitors
    Wang, Yixing
    Xu, Fang
    Zhou, Fu
    Dai, Liheng
    Qu, Kai
    Wu, Yulin
    Gu, Shuyun
    Xu, Zhi
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2022, 61 (25) : 8800 - 8808