Polvmer-BiI3 composites for high-performance, room-temperature, direct X-ray detectors

被引:7
|
作者
Chaudhari, Ritu [1 ]
Kant, Chhaya Ravi [1 ]
Garg, Alka [2 ]
机构
[1] Indira Gandhi Delhi Tech Univ Women, Dept Appl Sci & Humanities, Delhi 110006, India
[2] Univ Delhi, Gargi Coll, Siri Ft Rd, New Delhi 110049, India
关键词
CRYSTAL;
D O I
10.1557/s43579-022-00185-6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Low-energy X-rays have a predominant role in medical diagnostic applications, grown tremendously during recent Covid-19 pandemic times. Synthesis of stable, PMMA/polystyrene-BiI3 composites has been done through a facile, low-cost, dry-tumble mixing technique for direct X-ray detector applications. Comparative analysis of structural, optical, and photocurrent responses upon irradiation with low-energy X-rays (30 and 60 kV) ensue that PS-BiI3 demonstrates high SNR 3300, sensitivity 189 mu C Gy(-1) cm(-3) and fast response time 30 ms, at dose rate 1.68 mGy s(-1), affirming the composite to be prospective candidate for low-energy, room-temperature, direct X-ray detectors under low bias conditions.
引用
收藏
页码:358 / 364
页数:7
相关论文
共 50 条
  • [1] Polymer-BiI3 composites for high-performance, room-temperature, direct X-ray detectors
    Ritu Chaudhari
    Chhaya Ravi Kant
    Alka Garg
    MRS Communications, 2022, 12 : 358 - 364
  • [2] BiI3 single crystal for room-temperature gamma ray detectors
    Saito, T.
    Iwasaki, T.
    Kurosawa, S.
    Yoshikawa, A.
    Den, T.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 395 - 400
  • [3] CdTe and CdZnTe materials for room-temperature X-ray and gamma ray detectors
    Eisen, Y
    Shor, A
    JOURNAL OF CRYSTAL GROWTH, 1998, 184 : 1302 - 1312
  • [4] CdTe and CdZnTe room-temperature X-ray and gamma ray detectors and imaging systems
    Eisen, Y
    Shor, A
    SEMICONDUCTORS FOR ROOM-TEMPERATURE RADIATION DETECTOR APPLICATIONS II, 1997, 487 : 129 - 145
  • [5] A review on BiI3 perovskites and composites for direct X-ray detection
    Chaudhari, Ritu
    RaviKant, Chhaya
    SENSORS AND ACTUATORS A-PHYSICAL, 2022, 346
  • [6] Optimization of Room-Temperature Semiconductor Detectors for Energy-Resolved X-Ray Imaging
    Iwanczyk, Jan S.
    Nygard, Einar
    Wessel, Jan C.
    Malakhov, Nail
    Wawrzyniak, Gregor
    Hartsough, Neal E.
    Gandhi, Thulasi
    Barber, William C.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4745 - 4750
  • [7] Defects studies of BiI3-Polymer composites with carbon fillers to achieve better charge transportation for direct X-ray detectors
    Chaudhari, Ritu
    Kant, Chhaya Ravi
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2023, 163
  • [8] HIGH-PERFORMANCE, THERMOELECTRICALLY COOLED X-RAY AND GAMMA-RAY DETECTORS
    HUBER, AC
    PANTAZIS, JA
    JORDANOV, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1995, 99 (1-4): : 665 - 668
  • [9] Silicon drift detectors for high resolution room temperature X-ray spectroscopy
    Lechner, P
    Eckbauer, S
    Hartmann, R
    Krisch, S
    Hauff, D
    Richter, R
    Soltau, H
    Struder, L
    Fiorini, C
    Gatti, E
    Longoni, A
    Sampietro, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 377 (2-3): : 346 - 351
  • [10] PERFORMANCE OF ROOM-TEMPERATURE MERCURIC IODIDE (HGI2) DETECTORS IN THE ULTRALOW-ENERGY X-RAY REGION
    DABROWSKI, AJ
    IWANCZYK, JS
    BARTON, JB
    HUTH, GC
    WHITED, R
    ORTALE, C
    ECONOMOU, TE
    TURKEVICH, AL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1981, 28 (01) : 536 - 540