Scanning laser Doppler flowmetry shows reduced retinal capillary blood flow in CADASIL

被引:26
|
作者
Harju, M [1 ]
Tuominen, S
Summanen, P
Viitanen, M
Pöyhönen, M
Nikoskelainen, E
Kalimo, H
Kivelä, T
机构
[1] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Glaucoma Serv,PL 220, Helsinki 00029, Finland
[2] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Diabet Div,Vitreoretinal Serv, Helsinki 00029, Finland
[3] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Ophthalm Pathol Lab, Helsinki 00029, Finland
[4] Turku Univ, Cent Hosp, Dept Neurol, Turku, Finland
[5] Turku Univ, Cent Hosp, Dept Ophthalmol, Turku, Finland
[6] Turku Univ, Cent Hosp, Dept Geriatr Med, Turku, Finland
[7] Turku Univ, Cent Hosp, Dept Pathol, Turku, Finland
[8] Huddinge Hosp, Karolinska Inst, Div Geriatr Med, S-14186 Huddinge, Sweden
[9] Family Federat Finland, Dept Med Genet, Helsinki, Finland
[10] Univ Helsinki, Cent Hosp, Dept Pathol, FIN-00014 Helsinki, Finland
关键词
blood flow; CADASIL; ophthalmology; retinal vessels;
D O I
10.1161/01.STR.0000145048.94499.b9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is a progressive systemic nonatherosclerotic angiopathy which causes ischemic strokes and vascular subcortical dementia. A cross-sectional study was performed to examine the retinal vascular caliber and blood flow in CADASIL. Methods-Scanning laser Doppler flowmetry was used in a case-control study (11 patients and controls) of peripapillary retinal circulation. Automated full-field perfusion image analysis was used to analyze the flow data. Retinal vessel calibers were measured from retinal images acquired with scanning laser ophthalmoscopy. The caliber of the superior and inferior temporal retinal artery and vein were measured 1 and 2 mm from the disc rim, and the mean values were used for analysis. Results-Retinal capillary peak systolic flow (mean, 249 versus 311 arbitrary unit [AU]; P=0.072) was lower, and mean capillary flow (mean, 184 versus 224 AU; P=0.12) and minimum diastolic flow (mean, 105 versus 132 AU; P=0.16) tended to be lower in patients than in controls. No significant difference in the calibers of proximal retinal arteries (mean, 104 versus 108 mum) and veins (mean, 150 versus 145 mum) was found between the patients and controls. Conclusions-Retinal capillary blood flow is mild to moderately reduced in CADASIL but that does not appear to cause major ischemic injury. Such reduction is analogous to that in the cerebral cortex in CADASIL patients with which retina appears to share its relative sparing from severe arterial ischemic tissue damage.
引用
收藏
页码:2449 / 2452
页数:4
相关论文
共 50 条
  • [31] Blood flow in the human iris measured by laser Doppler flowmetry
    Chamot, SR
    Movaffaghy, AM
    Petrig, BL
    Riva, CE
    MICROVASCULAR RESEARCH, 1999, 57 (02) : 153 - 161
  • [32] ASSESSMENT OF GASTRIC BLOOD-FLOW WITH LASER DOPPLER FLOWMETRY
    AHN, H
    IVARSSON, LE
    JOHANSSON, K
    LINDHAGEN, J
    LUNDGREN, O
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1988, 23 (10) : 1203 - 1210
  • [33] TENDON BLOOD-FLOW ASSESSED BY LASER DOPPLER FLOWMETRY
    ASTROM, M
    SVENSSON, H
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1991, 25 (03): : 213 - 215
  • [34] MEASUREMENT OF COLONIC BLOOD-FLOW WITH LASER DOPPLER FLOWMETRY
    AHN, H
    LINDHAGEN, J
    LUNDGREN, O
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1986, 21 (07) : 871 - 880
  • [35] MEASUREMENT OF FLAP BLOOD-FLOW BY LASER DOPPLER FLOWMETRY
    GOTO, M
    ISHIKAWA, K
    KATSUKI, T
    LASERS IN DENTISTRY, 1989, 850 : 163 - 168
  • [36] LASER DOPPLER FLOWMETRY FOR MEASUREMENT OF LIVER BLOOD-FLOW
    ARVIDSSON, D
    SVENSSON, H
    HAGLUND, U
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1986, 5 (2-3): : 204 - 204
  • [37] Laser Doppler flowmetry and optic nerve head blood flow
    Petrig, BL
    Riva, CE
    Hayreh, SS
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1999, 127 (04) : 413 - 425
  • [38] CHOROIDAL BLOOD-FLOW BY LASER-DOPPLER FLOWMETRY
    RIVA, CE
    PETRIG, BL
    OPTICAL ENGINEERING, 1995, 34 (03) : 746 - 752
  • [39] Two-dimensional mapping of macular blood flow in high myopia by scanning laser doppler flowmetry
    Shih, YF
    Hwang, JK
    Wang, TH
    Lin, LLK
    Hung, PT
    Chen, MS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 622 - 622
  • [40] Diurnal blood flow change of optic disc and macula in normal subjects by scanning laser Doppler flowmetry
    Wang, TH
    Hung, PT
    Hwang, JK
    Shih, YF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1218 - 1218