Scanning laser Doppler flowmetry shows reduced retinal capillary blood flow in CADASIL

被引:26
|
作者
Harju, M [1 ]
Tuominen, S
Summanen, P
Viitanen, M
Pöyhönen, M
Nikoskelainen, E
Kalimo, H
Kivelä, T
机构
[1] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Glaucoma Serv,PL 220, Helsinki 00029, Finland
[2] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Diabet Div,Vitreoretinal Serv, Helsinki 00029, Finland
[3] Univ Helsinki, Cent Hosp, Dept Ophthalmol, Ophthalm Pathol Lab, Helsinki 00029, Finland
[4] Turku Univ, Cent Hosp, Dept Neurol, Turku, Finland
[5] Turku Univ, Cent Hosp, Dept Ophthalmol, Turku, Finland
[6] Turku Univ, Cent Hosp, Dept Geriatr Med, Turku, Finland
[7] Turku Univ, Cent Hosp, Dept Pathol, Turku, Finland
[8] Huddinge Hosp, Karolinska Inst, Div Geriatr Med, S-14186 Huddinge, Sweden
[9] Family Federat Finland, Dept Med Genet, Helsinki, Finland
[10] Univ Helsinki, Cent Hosp, Dept Pathol, FIN-00014 Helsinki, Finland
关键词
blood flow; CADASIL; ophthalmology; retinal vessels;
D O I
10.1161/01.STR.0000145048.94499.b9
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background and Purpose-Cerebral autosomal dominant arteriopathy with subcortical infarcts and leukoencephalopathy (CADASIL) is a progressive systemic nonatherosclerotic angiopathy which causes ischemic strokes and vascular subcortical dementia. A cross-sectional study was performed to examine the retinal vascular caliber and blood flow in CADASIL. Methods-Scanning laser Doppler flowmetry was used in a case-control study (11 patients and controls) of peripapillary retinal circulation. Automated full-field perfusion image analysis was used to analyze the flow data. Retinal vessel calibers were measured from retinal images acquired with scanning laser ophthalmoscopy. The caliber of the superior and inferior temporal retinal artery and vein were measured 1 and 2 mm from the disc rim, and the mean values were used for analysis. Results-Retinal capillary peak systolic flow (mean, 249 versus 311 arbitrary unit [AU]; P=0.072) was lower, and mean capillary flow (mean, 184 versus 224 AU; P=0.12) and minimum diastolic flow (mean, 105 versus 132 AU; P=0.16) tended to be lower in patients than in controls. No significant difference in the calibers of proximal retinal arteries (mean, 104 versus 108 mum) and veins (mean, 150 versus 145 mum) was found between the patients and controls. Conclusions-Retinal capillary blood flow is mild to moderately reduced in CADASIL but that does not appear to cause major ischemic injury. Such reduction is analogous to that in the cerebral cortex in CADASIL patients with which retina appears to share its relative sparing from severe arterial ischemic tissue damage.
引用
收藏
页码:2449 / 2452
页数:4
相关论文
共 50 条
  • [1] The impact of hypercapnia on retinal capillary blood flow assessed by scanning laser Doppler flowmetry
    Venkataraman, ST
    Hudson, C
    Fisher, JA
    Flanagan, JG
    MICROVASCULAR RESEARCH, 2005, 69 (03) : 149 - 155
  • [2] Peripapillary retinal capillary flow in diabetics using confocal scanning laser Doppler flowmetry
    Yamana, Y
    Matsuo, M
    DIABETOLOGIA, 1997, 40 : 1987 - 1987
  • [3] Variability of scanning laser Doppler flowmetry measurements of macular capillary blood flow.
    Pherwani, AA
    Hudson, C
    Silvestri, G
    Harvey, EP
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (04) : S213 - S213
  • [4] Validation of scanning laser Doppler flowmetry for retinal blood flow measurements in animal models
    Tamaki, Y
    Araie, M
    Fukaya, Y
    Ishi, K
    CURRENT EYE RESEARCH, 2002, 24 (05) : 332 - 340
  • [5] Retinal blood flow in branch retinal vein occlusion using scanning laser doppler flowmetry.
    Avila, CP
    Mueller, AJ
    Bartsch, DU
    Freeman, WR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4885 - 4885
  • [6] Retinal blood flow measurements in branch retinal vein occlusion using scanning laser Doppler flowmetry
    Avila, CP
    Bartsch, DU
    Bitner, DG
    Cheng, LY
    Mueller, AJ
    Karavellas, MP
    Freeman, WR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (05) : 683 - 690
  • [7] Reproducibility of retinal and optic nerve head blood flow measurements with scanning laser Doppler flowmetry
    Nicolela, MT
    Hnik, P
    Schulzer, M
    Drance, SM
    JOURNAL OF GLAUCOMA, 1997, 6 (03) : 157 - 164
  • [8] The optics of retinal blood vessels and their significance for scanning laser Doppler flowmetry
    Hammer, M
    Schweitzer, D
    Königsdorffer, E
    Strobel, J
    OPHTHALMOLOGE, 2001, 98 (09): : 844 - 847
  • [9] Laser Doppler flowmetry for measurement of laminar capillary blood flow in the horse
    Adair, HS
    LASERS IN SURGERY: ADVANCED CHARACTERIZATION, THERAPEUTICS, AND SYSTEMS VIII, PROCEEDINGS OF, 1998, 3245 : 422 - 425
  • [10] Variability of measurements in the optic nerve head and peripapillary retinal blood flow by scanning laser Doppler flowmetry
    Chung, ES
    Kim, DM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1210 - 1210