Evaluation of high density DRAMs as a nuclear radiation detector

被引:2
|
作者
Chou, HP [1 ]
Chou, TC [1 ]
Hau, TH [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Nucl Engn, Hsinchu 300, Taiwan
关键词
D O I
10.1016/S0969-8043(97)00160-7
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The research is based on the nuclear radiation induced soft error phenomenon associated with dynamic random access memory devices (DRAMs). Samples of 255 kbit and 1 Mbit decapped DRAMs from several manufacturers were exposed to standard alpha sources and showed a linear response with an intrinsic detection efficiency approaching 10%. Sensitivity studies were performed to evaluate the effects of DRAM operating voltage, refresh frequency and the data pattern stored prior to irradiation. The associated mechanism of soft error phenomenon is discussed. Samples were also exposed to gamma rays up to 10(5) rad to examine the total dose effect. The annealing phenomenon after gamma exposure is also presented. (C) 1997 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1601 / 1604
页数:4
相关论文
共 50 条
  • [21] Radiation damage evaluation of the CCD detector induced by high energy protons
    Wang, Zujun
    Xue, Yuanyuan
    Zhang, Fengqi
    Bian, Jingying
    Ma, Wuying
    Yao, Zhibin
    He, Baoping
    Sheng, Jiangkun
    Dong, Guantao
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 219 - 224
  • [22] A cell transistor scalable array architecture for high-density DRAMs
    Takashima, D
    Nakano, H
    2001 SYMPOSIUM ON VLSI CIRCUITS, DIGEST OF TECHNICAL PAPERS, 2001, : 31 - 32
  • [23] Low temperature MOCVD of BST thin film for high density DRAMs
    Cho, HJ
    Park, JB
    Yu, YS
    Roh, JS
    Yoon, HK
    PROCEEDINGS OF THE 2001 12TH IEEE INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF FERROELECTRICS, VOLS I AND II, 2001, : 55 - 58
  • [24] NEW NIBBLED-PAGE ARCHITECTURE FOR HIGH-DENSITY DRAMS
    NUMATA, K
    OOWAKI, Y
    ITOH, Y
    HARA, T
    TSUCHIDA, K
    OHTA, M
    WATANABE, S
    OHUCHI, K
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1989, 24 (04) : 900 - 904
  • [25] DECODED-SOURCE SENSE AMPLIFIER FOR HIGH-DENSITY DRAMS
    OKAMURA, JI
    OKADA, Y
    KOYANAGI, M
    TAKEUCHI, Y
    YAMADA, M
    SAKURAI, K
    IMADA, S
    SAITO, S
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1990, 25 (01) : 18 - 23
  • [26] NEUTRON SPECTROMETRY BY DIAMOND DETECTOR FOR NUCLEAR RADIATION
    KOZLOV, SF
    KONOROVA, EA
    BARINOV, AL
    JARKOV, VP
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1975, NS22 (01) : 171 - 172
  • [27] Design of Remote Control Nuclear Radiation Detector
    郭银景
    李瑾
    丁晓明
    Journal of Measurement Science and Instrumentation, 2011, 2 (04) : 390 - 393
  • [28] Thallium Bromide Nuclear Radiation Detector Development
    Churilov, Alexei V.
    Ciampi, Guido
    Kim, Hadong
    Cirignano, Leonard J.
    Higgins, William M.
    Olschner, Fred
    Shah, Kanai S.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (04) : 1875 - 1881
  • [29] Thallium Bromide Nuclear Radiation Detector Development
    Churilov, Alexei V.
    Ciampi, Guido
    Kim, Hadong
    Cirignano, Leonard J.
    Higgins, William M.
    Olschner, Fred
    Shah, Kanai S.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4992 - +
  • [30] THE PIN DETECTOR - A SIMPLE, ROBUST, CHEAP AND EFFECTIVE NUCLEAR RADIATION DETECTOR
    BATEMAN, JE
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 238 (2-3): : 524 - 532