Intravoxel Incoherent Motion Diffusion-Weighted MRI of the Abdomen: The Effect of Fitting Algorithms on the Accuracy and Reliability of the Parameters

被引:48
|
作者
Park, Hyo Jung [1 ,2 ]
Sung, Yu Sub [1 ,2 ]
Lee, Seung Soo [1 ,2 ]
Lee, Yedaun [3 ]
Cheong, Hyunhee [1 ,2 ]
Kim, Yeong Jae [1 ,2 ]
Lee, Moon-gyu [1 ,2 ]
机构
[1] Univ Ulsan, Dept Radiol, Coll Med, Asan Med Ctr, 88 Olympic Ro 43 Gil, Seoul 138736, South Korea
[2] Univ Ulsan, Res Inst Radiol, Coll Med, Asan Med Ctr, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
[3] Inje Univ, Coll Med, Haeundae Paik Hosp, Dept Radiol, Busan, South Korea
基金
新加坡国家研究基金会;
关键词
PANCREATIC NEUROENDOCRINE TUMORS; FATTY LIVER-DISEASE; HISTOLOGIC GRADE; BREAST-CANCER; OPTIMIZATION; COEFFICIENT; REPRODUCIBILITY; REPEATABILITY; VARIABILITY; METASTASES;
D O I
10.1002/jmri.25535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the influence of fitting methods on the accuracy and reliability of intravoxel incoherent motion (IVIM) parameters, with a particular emphasis on the constraint function. Materials and Methods Diffusion-weighted (DW) imaging data were analyzed using IVIM-based full-fitting (simultaneous fit of all parameters) and segmented-fitting (step-by-step fit of each parameter), each with and without the constraint function, to estimate the molecular diffusion coefficient (D-slow), perfusion fraction (f), and flow-related diffusion coefficient (D-fast). Computational simulations were performed at variable signal-to-noise ratios to evaluate the relative error (RE) and coefficient of variation (CV) of the estimated IVIM parameters. DW imaging of the abdomen was performed twice at 1.5 Tesla using nine b-values (0-900 s/mm(2)) in 12 health volunteers (6 men and 6 women; mean age: 30 years). The measurement repeatability of IVIM parameters in the liver and the pancreas was evaluated using the within-subject coefficient of variation (wCV). ResultsIn simulations, full-fitting without the constraint function yielded the largest RE (P<0.001 for D-slow and f; P < 0.044 for D-fast) and CV (P < 0.033 for D-slow and f; P < 0.473 for D-fast) for IVIM parameters among all four algorithms. In volunteer imaging, full-fitting without the constraint function also resulted in the poorest repeatability for D-slow (wCV, 17.12%-65.45%) and f (wCV, 19.35%-42.84%) in the liver and pancreas, while the other algorithms had similar repeatability values (wCV, 4.05%-11.99% for D-slow and 9.65%-18.66% for f). Measurement repeatability of D-fast (wCV, 29.52%-85.01%) was the poorest among the IVIM parameters. Conclusion For accurate and reliable measurement of IVIM parameters, segmented fitting or full-fitting with the constraint function should be used for IVIM-based analysis of DW imaging.
引用
收藏
页码:1637 / 1647
页数:11
相关论文
共 50 条
  • [31] Monitoring Bevacizumab-Induced Tumor Vascular Normalization by Intravoxel Incoherent Motion Diffusion-Weighted MRI
    Li, Bo
    Xu, Dan
    Zhou, Jie
    Wang, Shou-Chao
    Cai, Yu-Xiang
    Li, Huan
    Xu, Hai-Bo
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (02) : 427 - 439
  • [32] Intravoxel incoherent motion diffusion-weighted MR imaging of solid pancreatic masses: reliability and usefulness for characterization
    De Robertis, Riccardo
    Cardobi, Nicolo
    Ortolani, Silvia
    Martini, Paolo Tinazzi
    Stemmer, Alto
    Grimm, Robert
    Gobbo, Stefano
    Butturini, Giovanni
    D'Onofrio, Mirko
    [J]. ABDOMINAL RADIOLOGY, 2019, 44 (01) : 131 - 139
  • [33] Intravoxel incoherent motion diffusion-weighted MRI in patients with breast cancer: Correlation with tumor stroma characteristics
    Yuan, Li
    Wang, Zhengping
    Chen, Feng
    Qin, Xin
    Li, Changqing
    Zhao, Yingman
    Yan, Chenggong
    Wu, Yuankui
    Hao, Peng
    Xu, Yikai
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2019, 120
  • [34] Intravoxel incoherent motion diffusion-weighted MR imaging of solid pancreatic masses: reliability and usefulness for characterization
    Riccardo De Robertis
    Nicolò Cardobi
    Silvia Ortolani
    Paolo Tinazzi Martini
    Alto Stemmer
    Robert Grimm
    Stefano Gobbo
    Giovanni Butturini
    Mirko D’Onofrio
    [J]. Abdominal Radiology, 2019, 44 : 131 - 139
  • [35] Reproducibility of radiomics features derived from intravoxel incoherent motion diffusion-weighted MRI of cervical cancer
    Chen, Hao
    He, Yaoyao
    Zhao, Cecheng
    Zheng, Lili
    Pan, Ning
    Qiu, Jianfeng
    Zhang, Zhaoxi
    Niu, Xiaohui
    Yuan, Zilong
    [J]. ACTA RADIOLOGICA, 2021, 62 (05) : 679 - 686
  • [36] Tumor vascular normalization monitor by non-contrast intravoxel incoherent motion diffusion-weighted MRI
    Pan, Yunlong
    Pan Jinghua
    Zhao, Xiaoxu
    Ding, Hui
    Huang, Jinlian
    Zhu, Shengbin
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2018, 36 (15)
  • [37] Standard diffusion-weighted, diffusion kurtosis and intravoxel incoherent motion in differentiating invasive placentas
    Tao Lu
    Mou Li
    Yishuang Wang
    Hang Li
    Mingpeng Wu
    Guotai Wang
    [J]. Archives of Gynecology and Obstetrics, 2024, 309 : 503 - 514
  • [38] Standard diffusion-weighted, diffusion kurtosis and intravoxel incoherent motion in differentiating invasive placentas
    Lu, Tao
    Li, Mou
    Wang, Yishuang
    Li, Hang
    Wu, Mingpeng
    Wang, Guotai
    [J]. ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2023, 309 (2) : 503 - 514
  • [39] Intravoxel incoherent motion diffusion-weighted imaging in the characterization of Alzheimer’s disease
    Nengzhi Xia
    Yanxuan Li
    Yingnan Xue
    Weikang Li
    Zhenhua Zhang
    Caiyun Wen
    Jiance Li
    Qiong Ye
    [J]. Brain Imaging and Behavior, 2022, 16 : 617 - 626
  • [40] Diffusion-Weighted Intravoxel Incoherent Motion Imaging of Renal Tumors With Histopathologic Correlation
    Chandarana, Hersh
    Kang, Stella K.
    Wong, Samson
    Rusinek, Henry
    Zhang, Jeff L.
    Arizono, Shigeki
    Huang, William C.
    Melamed, Jonathan
    Babb, James S.
    Suan, Edgar F.
    Lee, Vivian S.
    Sigmund, Eric E.
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (12) : 688 - 696