Intravoxel Incoherent Motion Diffusion-Weighted MRI of the Abdomen: The Effect of Fitting Algorithms on the Accuracy and Reliability of the Parameters

被引:48
|
作者
Park, Hyo Jung [1 ,2 ]
Sung, Yu Sub [1 ,2 ]
Lee, Seung Soo [1 ,2 ]
Lee, Yedaun [3 ]
Cheong, Hyunhee [1 ,2 ]
Kim, Yeong Jae [1 ,2 ]
Lee, Moon-gyu [1 ,2 ]
机构
[1] Univ Ulsan, Dept Radiol, Coll Med, Asan Med Ctr, 88 Olympic Ro 43 Gil, Seoul 138736, South Korea
[2] Univ Ulsan, Res Inst Radiol, Coll Med, Asan Med Ctr, 88 Olymp Ro 43 Gil, Seoul 138736, South Korea
[3] Inje Univ, Coll Med, Haeundae Paik Hosp, Dept Radiol, Busan, South Korea
基金
新加坡国家研究基金会;
关键词
PANCREATIC NEUROENDOCRINE TUMORS; FATTY LIVER-DISEASE; HISTOLOGIC GRADE; BREAST-CANCER; OPTIMIZATION; COEFFICIENT; REPRODUCIBILITY; REPEATABILITY; VARIABILITY; METASTASES;
D O I
10.1002/jmri.25535
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To evaluate the influence of fitting methods on the accuracy and reliability of intravoxel incoherent motion (IVIM) parameters, with a particular emphasis on the constraint function. Materials and Methods Diffusion-weighted (DW) imaging data were analyzed using IVIM-based full-fitting (simultaneous fit of all parameters) and segmented-fitting (step-by-step fit of each parameter), each with and without the constraint function, to estimate the molecular diffusion coefficient (D-slow), perfusion fraction (f), and flow-related diffusion coefficient (D-fast). Computational simulations were performed at variable signal-to-noise ratios to evaluate the relative error (RE) and coefficient of variation (CV) of the estimated IVIM parameters. DW imaging of the abdomen was performed twice at 1.5 Tesla using nine b-values (0-900 s/mm(2)) in 12 health volunteers (6 men and 6 women; mean age: 30 years). The measurement repeatability of IVIM parameters in the liver and the pancreas was evaluated using the within-subject coefficient of variation (wCV). ResultsIn simulations, full-fitting without the constraint function yielded the largest RE (P<0.001 for D-slow and f; P < 0.044 for D-fast) and CV (P < 0.033 for D-slow and f; P < 0.473 for D-fast) for IVIM parameters among all four algorithms. In volunteer imaging, full-fitting without the constraint function also resulted in the poorest repeatability for D-slow (wCV, 17.12%-65.45%) and f (wCV, 19.35%-42.84%) in the liver and pancreas, while the other algorithms had similar repeatability values (wCV, 4.05%-11.99% for D-slow and 9.65%-18.66% for f). Measurement repeatability of D-fast (wCV, 29.52%-85.01%) was the poorest among the IVIM parameters. Conclusion For accurate and reliable measurement of IVIM parameters, segmented fitting or full-fitting with the constraint function should be used for IVIM-based analysis of DW imaging.
引用
收藏
页码:1637 / 1647
页数:11
相关论文
共 50 条
  • [1] A comparison of fitting algorithms for diffusion-weighted MRI data analysis using an intravoxel incoherent motion model
    Roberta Fusco
    Mario Sansone
    Antonella Petrillo
    [J]. Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 113 - 120
  • [2] A comparison of fitting algorithms for diffusion-weighted MRI data analysis using an intravoxel incoherent motion model
    Fusco, Roberta
    Sansone, Mario
    Petrillo, Antonella
    [J]. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (02) : 113 - 120
  • [3] An In Vivo Verification of the Intravoxel Incoherent Motion Effect in Diffusion-Weighted Imaging of the Abdomen
    Lemke, Andreas
    Laun, Frederik B.
    Simon, Dirk
    Stieltjes, Bram
    Schad, Lothar R.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (06) : 1580 - 1585
  • [4] Stroke assessment with intravoxel incoherent motion diffusion-weighted MRI
    Suo, Shiteng
    Cao, Mengqiu
    Zhu, Wanqiu
    Li, Lei
    Li, Jun
    Shen, Fei
    Zu, Jinyan
    Zhou, Zien
    Zhuang, Zhiguo
    Qu, Jianxun
    Chen, Zengai
    Xu, Jianrong
    [J]. NMR IN BIOMEDICINE, 2016, 29 (03) : 320 - 328
  • [5] Esophageal carcinoma: Intravoxel incoherent motion diffusion-weighted MRI parameters and histopathological correlations
    Zhu, Shaocheng
    Wei, Yi
    Gao, Feifei
    Li, Linlin
    Liu, Yuehua
    Huang, Zixing
    Tang, Hehan
    Zheng, Dandan
    Wei, Xiaocheng
    Sun, Tingyi
    Song, Bin
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (01) : 253 - 261
  • [6] Intravoxel Incoherent Motion in Body Diffusion-Weighted MRI: Reality and Challenges
    Koh, Dow-Mu
    Collins, David J.
    Orton, Matthew R.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : 1351 - 1361
  • [7] A comparative simulation study of bayesian fitting approaches to intravoxel incoherent motion modeling in diffusion-weighted MRI
    While, Peter T.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2373 - 2387
  • [8] Reliable estimation of brain intravoxel incoherent motion parameters using denoised diffusion-weighted MRI
    Huang, Hsuan-Ming
    [J]. NMR IN BIOMEDICINE, 2020, 33 (04)
  • [9] Evaluation of Hepatic Tumors Using Intravoxel Incoherent Motion Diffusion-Weighted MRI
    Wang, Mingjie
    Li, Xudan
    Zou, Jianxun
    Chen, Xugao
    Chen, Shuyan
    Xiang, Wanqing
    [J]. MEDICAL SCIENCE MONITOR, 2016, 22 : 702 - 709
  • [10] Evaluation of Hepatic Fibrosis Using Intravoxel Incoherent Motion in Diffusion-Weighted Liver MRI
    Yoon, Jeong Hee
    Lee, Jeong Min
    Baek, Jee Hyun
    Shin, Cheong-il
    Kiefer, Berthold
    Han, Joon Koo
    Choi, Byung-Ihn
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (01) : 110 - 116