Dependence of the Chopping Current Level of a Vacuum Interrupter on Parallel Capacitance

被引:4
|
作者
Dullni, Edgar [1 ]
Lindell, Elisabeth [2 ]
Liljestrand, Lars [2 ]
机构
[1] ABB AG, D-40472 Ratingen, Germany
[2] ABB AB Corp Res, S-72178 Vasteras, Sweden
关键词
Arc discharge; current measurement; traveling waves; vacuum interrupter; ARCS;
D O I
10.1109/TPS.2017.2695329
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The distribution of chopping currents of a vacuum circuit breaker using CuCr25 contact material was measured in a laboratory circuit consisting of a three-phase 20-kV cable system and a dry-type distribution transformer rated 900 kVA. The cable length between the upstream feeding transformer and the circuit breaker was several hundreds of meters. An inductive load connected to the distribution transformer provided a 50-Hz current of 10 A rms. Under these conditions, the mean chopping current level was between 3.2 and 3.5 A and showed no significant dependence on the arcing time, which was varied between 2 and 8 ms. After addition of a surge capacitor of 130 nF between the transformer terminals and ground, which very much reduces the overvoltage during switching, the chopping current level increased to 5.6 to 7.7 A in dependence of the arcing time. In order to explain this, the interaction of the arc with the electric circuit in particular with the cables on both sides of the breaker has to be evaluated. If the cables are long, travelling waves need to be considered as well as all return current paths in a three-phase circuit. The coincidence of excited network oscillations with random arc instabilities may result in either momentary amplification or damping of such oscillations. An additionally installed capacitor serves as a source sustaining a momentary current reduction after an arc instability and allows the excitation of a subsequent arc instability leading to an increase of the chopping current with longer arcing times. With low capacitance on the load side, there is no interaction and therefore no influence from the arcing time.
引用
收藏
页码:2150 / 2156
页数:7
相关论文
共 50 条
  • [41] Comparison of Artificial Current Zero Impulses for a Vacuum Interrupter Based Direct Current Circuit Breaker
    Heinz, T.
    Hock, P.
    Hinrichsen, V.
    2016 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 2, 2016,
  • [42] Simulation on the High Current Interruption Principle for Hybrid Circuit Breaker of Vacuum Interrupter and CO2 Gas Interrupter
    Chen, Zhan-qing
    Cheng, Xian
    Jiao, Lian-yao
    Ge, Guo-wei
    2016 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 2, 2016,
  • [44] Measuring and Analysing the Chopping Current and Switching Overvoltages with various Vacuum Interrupters.
    Japundzic, S.
    Hulenic, Z.
    Elektrotehnika Zagreb, 1987, 30 (04): : 165 - 173
  • [45] VOLTAGE EFFECTS OF LOW AND HIGH-CURRENT ARCING ON VACUUM INTERRUPTER CONTACTS
    FARRALL, GA
    IEEE TRANSACTIONS ON PARTS HYBRIDS AND PACKAGING, 1975, PH11 (02): : 134 - 138
  • [46] Insulation recovery characteristics after current interruption by various vacuum interrupter electrodes
    Matsuo, T
    Fujimori, H
    Yanabu, S
    Ichikawa, H
    Matsui, Y
    Sakaki, M
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2006, 13 (01) : 10 - 17
  • [47] Deformation of contact surfaces in a vacuum interrupter after high-current interruptions
    Wang, Haoran
    Wang, Zhenxing
    Zhou, Zhipeng
    Jiang, Yanjun
    Wang, Jianhua
    Geng, Yingsan
    Liu, Zhiyuan
    JOURNAL OF APPLIED PHYSICS, 2016, 120 (05)
  • [48] Fiber-Controlled Vacuum Interrupter Module Used for Fault Current Interruption
    Duan Xiongying
    Liao Minfu
    Zou Jiyan
    Huang Zhihui
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 165 - 168
  • [49] V-t characteristics of vacuum interrupter after large current interruption
    Sato, S.
    Ikeda, H.
    Nishimura, S.
    Harada, K.
    Taniguchi, Y.
    Shimizu, H.
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 67 - 70
  • [50] Dielectric strength of a vacuum interrupter contact gap after making current operations
    Zalucki, Z
    Kutzner, J