Dependence of the Chopping Current Level of a Vacuum Interrupter on Parallel Capacitance

被引:4
|
作者
Dullni, Edgar [1 ]
Lindell, Elisabeth [2 ]
Liljestrand, Lars [2 ]
机构
[1] ABB AG, D-40472 Ratingen, Germany
[2] ABB AB Corp Res, S-72178 Vasteras, Sweden
关键词
Arc discharge; current measurement; traveling waves; vacuum interrupter; ARCS;
D O I
10.1109/TPS.2017.2695329
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The distribution of chopping currents of a vacuum circuit breaker using CuCr25 contact material was measured in a laboratory circuit consisting of a three-phase 20-kV cable system and a dry-type distribution transformer rated 900 kVA. The cable length between the upstream feeding transformer and the circuit breaker was several hundreds of meters. An inductive load connected to the distribution transformer provided a 50-Hz current of 10 A rms. Under these conditions, the mean chopping current level was between 3.2 and 3.5 A and showed no significant dependence on the arcing time, which was varied between 2 and 8 ms. After addition of a surge capacitor of 130 nF between the transformer terminals and ground, which very much reduces the overvoltage during switching, the chopping current level increased to 5.6 to 7.7 A in dependence of the arcing time. In order to explain this, the interaction of the arc with the electric circuit in particular with the cables on both sides of the breaker has to be evaluated. If the cables are long, travelling waves need to be considered as well as all return current paths in a three-phase circuit. The coincidence of excited network oscillations with random arc instabilities may result in either momentary amplification or damping of such oscillations. An additionally installed capacitor serves as a source sustaining a momentary current reduction after an arc instability and allows the excitation of a subsequent arc instability leading to an increase of the chopping current with longer arcing times. With low capacitance on the load side, there is no interaction and therefore no influence from the arcing time.
引用
收藏
页码:2150 / 2156
页数:7
相关论文
共 50 条
  • [1] Dependence of the Chopping Current Level of a Vacuum Interrupter on Parallel Capacitance
    Lindell, E.
    Liljestrand, L.
    Dullni, E.
    PROCEEDINGS OF THE 27TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV), VOL 1, 2016, : 161 - 164
  • [2] Investigation of transient electric field of vacuum interrupter during current chopping
    Gao, YH
    Wang, EZ
    Hong, Y
    ISDEIV: XXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, PROCEEDINGS, 2002, 20 : 507 - 510
  • [3] DEPENDENCE OF CHOPPING CURRENT OF A VACUUM ARC ON AMBIENT PRESSURE AND ELECTRODE DISTANCE
    SCHUOCKER, D
    REIF, W
    APPLIED PHYSICS, 1975, 7 (04): : 279 - 285
  • [4] ARC INSTABILITY AND CURRENT CHOPPING IN AN AIR-BLAST INTERRUPTER
    GARDNER, GE
    URWIN, RJ
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1977, 124 (07): : 619 - 627
  • [5] The chopping current level of vacuum interrupters influenced by the arc quenching operations
    Dan, SH
    Wang, Z
    Wang, JM
    Wu, JW
    ISDEIV: XIXTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, VOLS 1 AND 2, PROCEEDINGS, 2000, 19 : 536 - 539
  • [6] THE ORIGIN OF CURRENT CHOPPING IN VACUUM ARCS
    SMEETS, RPP
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1989, 17 (02) : 303 - 310
  • [7] ARC INSTABILITY AND CURRENT CHOPPING IN AN AIR-BLAST INTERRUPTER - DISCUSSION
    GONEK, SM
    MORRIS, C
    BOYLE, D
    RYAN, HM
    LUGTON, WT
    BLACKETT, J
    GARDNER, GE
    URWIN, RW
    PROCEEDINGS OF THE INSTITUTION OF ELECTRICAL ENGINEERS-LONDON, 1978, 125 (10): : 1027 - 1029
  • [8] Experimental Study of Dynamics of Current Redistribution at Parallel Connection of Vacuum Interrupter and Diode Assembly
    Popov, S. A.
    Schneider, A. V.
    Batrakov, A. V.
    Lavrinovich, V. A.
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 501 - 503
  • [9] Increase of Current Carrying Ability of Vacuum Interrupter
    Sato, Y.
    Arazoe, S.
    Okumo, H.
    Takao, N.
    Yanabu, S.
    ISDEIV 2010: XXIVTH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM, 2010, : 197 - 200
  • [10] Uses of Magnetron Discharge to Assess the Vacuum Level of Vacuum Interrupter
    Acharya, Viren
    Kulkarni, Sandeep
    Rajhans, Rupesh
    Paulzagade, Dinesh
    PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 1, 2018, : 93 - 96