Determination of lead in hair and its segmental analysis by solid sampling electrothermal atomic absorption spectrometry

被引:29
|
作者
Baysal, Asli [1 ]
Akman, Suleyman [1 ]
机构
[1] Istanbul Tech Univ, Dept Chem, Fac Sci & Letters, TR-34469 Istanbul, Turkey
关键词
Solid sampling ETAAS; Lead; Hair; Segmental analysis; PLASMA-MASS SPECTROMETRY; BIOLOGICAL SAMPLES; TRACE-ELEMENTS; BREAST-CANCER; SCALP HAIR; POPULATION; METALS; STRAND; COPPER; DRUGS;
D O I
10.1016/j.sab.2010.02.016
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A rapid and practical solid sampling electrothermal atomic absorption spectrometric method was described for the determination of lead in scalp hair. Hair samples were washed once with acetone: thrice with distilled-deionized water and again once with acetone and dried at 75 degrees C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The effects of pyrolysis temperature, atomization temperature, the amount of sample as well as addition of a modifier (Pd/Mg) and/or auxiliary digesting agents (hydrogen peroxide and nitric acid) and/or a surfactant (Triton X-100) on the recovery of lead were investigated. Hair samples were washed once with acetone; thrice with distilled-deionized water and again once with acetone and dried at 75 degrees C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The limit of detection for lead (3 sigma, N = 10) was 0.3 ng/g The addition of modifier, acids, oxidant and surfactant hardly improved the results. Due to the risk of contamination and relatively high blank values, the lead in hair were determined directly without adding any reagent(s). Finally, the method was applied for the segmental determination of lead concentrations in hair of different persons which is important to know when and how much a person was exposed to the analyte. For this purpose, 0.5 cm of pieces were cut along the one or a few close strands and analyzed by solid sampling. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:340 / 344
页数:5
相关论文
共 50 条
  • [21] Determination of aluminium and manganese in human scalp hair by electrothermal atomic absorption spectrometry using slurry sampling
    Bermejo-Barrera, P
    Moreda-Pineiro, A
    Moreda-Pineiro, J
    Bermejo-Barrera, A
    TALANTA, 1998, 45 (06) : 1147 - 1154
  • [22] Determination of vanadium in human hair slurries by electrothermal atomic absorption spectrometry
    Fernandes, Kelly G.
    Nogueira, Ana Rita A.
    Neto, Jose A. Gomes
    Nobrega, Joaquim A.
    TALANTA, 2007, 71 (03) : 1118 - 1123
  • [23] Determination of Metal Impurities in Carbon Nanotubes by Direct Solid Sampling Electrothermal Atomic Absorption Spectrometry
    Mello, Paola A.
    Rodrigues, Luiz Frederico
    Nunes, Matheus A. G.
    Mattos, Julio Cezar P.
    Mueller, Edson I.
    Dressler, Valderi L.
    Flores, Erico M. M.
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2011, 22 (06) : 1040 - U62
  • [24] A solid sampling electrothermal atomic absorption spectrometry method for direct determination of silicon in titanium pieces
    Dong, HM
    Krivan, V
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (04) : 367 - 371
  • [25] Stabilizing Agents for Calibration in the Determination of Mercury Using Solid Sampling Electrothermal Atomic Absorption Spectrometry
    Zelinkova, Hana
    Cervenka, Rostislav
    Komarek, Josef
    SCIENTIFIC WORLD JOURNAL, 2012,
  • [26] Determination of trace impurities in titanium dioxide by direct solid sampling electrothermal atomic absorption spectrometry
    Docekal, Bohumil
    Vojtkova, Blanka
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (03) : 304 - 308
  • [27] A direct solid sampling electrothermal atomic absorption spectrometry method for the determination of silicon in biological materials
    Huang, M. D.
    Krivan, V.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2007, 62 (03) : 297 - 303
  • [28] Analysis of the distribution of lead, cadmium and mercury in the avian kidney by means of direct solid sampling electrothermal atomic absorption spectrometry
    Lucker, E
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (7-8): : 848 - 853
  • [29] Analysis of the distribution of lead, cadmium and mercury in the avian kidney by means of direct solid sampling electrothermal atomic absorption spectrometry
    Ernst Lücker
    Fresenius' Journal of Analytical Chemistry, 1997, 358 : 848 - 853
  • [30] Comparison of direct solid sampling and slurry sampling for the determination of cadmium in wheat flour by electrothermal atomic absorption spectrometry
    Araujo, Rennan G. O.
    Oleszczuk, Nedio
    Rampazzo, Roger T.
    Costa, Pedro A.
    Silva, Mdrcia M.
    Vale, Maria Goreti R.
    Welz, Bernhard
    Ferreira, Sergio L. C.
    TALANTA, 2008, 77 (01) : 400 - 406