Neutron-photon discrimination and spectrum unfolding with a stilbene detector

被引:5
|
作者
Mertens, C. [1 ]
De Lellis, C. [2 ]
Tondeur, F. [1 ]
机构
[1] Inst Super Ind Bruxelles, BE-1000 Brussels, Belgium
[2] Inst Natl Radioelements, BE-6220 Fleurus, Belgium
关键词
Scintillation detector; Neutron photon discrimination; MCNPX; Spectrum unfolding;
D O I
10.1016/j.apradiso.2009.10.014
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
As a first step into the development of a neutron dose monitor, a stilbene detector is used to test a procedure applicable to other organic scintillators allowing for neutron-photon discrimination. The pulses are measured by numerical acquisition and their amplitude and decay time are calculated by software. The discrimination is performed in an amplitude-decay time plot, and separate amplitude spectra are built. These spectra are unfolded MAXED, using the detector response matrices calculated with MCNPX. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:957 / 960
页数:4
相关论文
共 50 条
  • [31] Neutron Discrimination Evaluation of Neutron Diagnostic System using Stilbene Scintillator
    Son, Jaebum
    Park, Junesic
    Kim, Yong Kyun
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [32] Study on neutron energy spectrum unfolding algorithm with EJ309 liquid scintillation detector
    Yang, Xu
    Wei, Zheng
    Zhang, Shi-Yu
    Yu, Xiao-Xue
    Zhang, Peng-Qi
    Bai, Xiao-Hou
    Wu, Kang
    Huo, Dong-Ying
    Li, Ming
    Peng, Jing-Qiu
    Yao, Ze-En
    Zhang, Yu
    Wang, Jun-Run
    Deng, Zhi-Yong
    Wu, Lu
    Gao, Gen-Tao
    APPLIED RADIATION AND ISOTOPES, 2023, 201
  • [33] Results of a randomized prospective trial of sequential neutron-photon versus photon-neutron irradiation in organ confined prostate cancer
    Forman, JD
    Tekyi-Mensah, S
    Bolton, S
    Ben-Josef, E
    Porter, AT
    Maughan, RL
    CANCER JOURNAL, 2001, 7 (06): : 526 - 527
  • [34] Development and evaluation of a neutron-photon shield for transuranic (TRU) waste drums.
    Castro, J
    Montague, C
    Wannigman, D
    Wishau, R
    HEALTH PHYSICS, 2002, 82 (06): : S138 - S138
  • [35] Calibration of personal dosemeters in mixed neutron-photon fields: Some problems and their solution
    Schuhmacher, H.
    Nolte, R.
    Wiegel, B.
    Zimbal, A.
    RADIATION PROTECTION DOSIMETRY, 2007, 126 (1-4) : 482 - 486
  • [36] Dosimetric specification of mixed neutron-photon fields at the Czech nuclear power plant
    Kralik, M
    Novotny, T
    Studeny, J
    NEUTRONS IN RESEARCH AND INDUSTRY, INTERNATIONAL CONFERENCE, 1997, 2867 : 296 - 299
  • [37] Measured and simulated 252Cf(sf) prompt neutron-photon competition
    Marcath, Matthew J.
    Haight, Robert C.
    Vogt, Ramona
    Devlin, Matthew
    Talou, Patrick
    Stetcu, Ionel
    Randrup, Jorgen
    Schuster, Patricia F.
    Clarke, Shaun D.
    Pozzi, Sara A.
    PHYSICAL REVIEW C, 2018, 97 (04)
  • [38] Validation of coupled neutron-photon transport mode of Monte Carlo code MCS
    Lemaire, Matthieu
    Setiawan, Fathurrahman
    Lee, Hyunsuk
    Zhang, Peng
    Lee, Deokjung
    International Conference on Mathematics and Computational Methods Applied to Nuclear Science and Engineering, M and C 2019, 2019, : 588 - 597
  • [39] CORRECTION FOR FISSION NEUTRON DETECTOR EFFICIENCY AND UNFOLDING OF NEUTRON MULTIPLICITY HISTOGRAMS
    NIFENECKER, H
    NUCLEAR INSTRUMENTS & METHODS, 1970, 81 (01): : 45 - +
  • [40] NEUTRON-PHOTON MULTIGROUP CROSS-SECTIONS FOR NEUTRON ENERGIES LESS-THAN-OR-EQUAL-TO 60 MEV
    ALSMILLER, RG
    BARISH, J
    NUCLEAR SCIENCE AND ENGINEERING, 1979, 69 (03) : 378 - 388