Trimester-specific reference intervals for thyroxine and triiodothyronine in pregnancy in iodine-sufficient women using isotope dilution tandem mass spectrometry and immunoassays

被引:45
|
作者
Soldin, OP
Hilakivi-Clarke, L
Weiderpass, E
Soldin, SJ
机构
[1] Georgetown Univ, Med Ctr, Vincent T Lombardi Canc Res Ctr, Div Canc Genet & Epidemiol, Washington, DC 20007 USA
[2] Georgetown Univ, Dept Pharmacol & Endocrinol, Washington, DC 20007 USA
[3] Karolinska Inst, Dept Med Epidemiol & Biostat, Stockholm, Sweden
[4] Int Agcy Res Canc, F-69372 Lyon, France
[5] Finnish Canc Registry, FIN-00170 Helsinki, Finland
[6] Canc Registry Norway, Oslo, Norway
[7] Georgetown Univ, Georgetown Clin Res Ctr, Bioanalyt Core Lab, Washington, DC USA
[8] George Washington Univ, Childrens Natl Med Ctr, Washington, DC USA
关键词
thyroxine T4; triiodothyronine T3; reference intervals; pregnancy; thyroid hormones; isotope dilution tandem mass spectrometry LC/MS/MS;
D O I
10.1016/j.cccn.2004.06.021
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Accurate assessment of the pregnant woman's thyroid status is critical, for both the initiation of thyroid hormone therapy and for the adjustment of thyroid hormone dose in those already receiving thyroid hormone. Trimester-specific intervals are especially important during pregnancy when thyroid insufficiency may be associated with adverse obstetric outcome and fetal neurodevelopmental deficits. We defined pregnancy-specific reference intervals for thyroxine (T4) and 3,5,3'-triiodothyronine (T3). We used a novel isotope dilution tandem mass spectrometry (LC/MS/MS) method, and compare these to reference intervals obtained by immunoassays (IAs) performed on the same samples. Methods: Concentrations of circulating T4 and T3 were measured simultaneously during first, second and third trimesters and postpartum in iodine-sufficient, healthy, singleton pregnancies using API-3000 LC/MS/MS with deuterium-labeled internal standard (L-thyroxine-d(2)). Immunoassays were conducted on the same samples (T4 Dade Behring RxL, T3 DPC-Immumolite). Results: Linear regression is reported for method comparisons; for T4, the slope decreased from r=0.900 in nonpregnant women to 0.802-0.820 during pregnancy. For T3, correlations between LC/MS/MS and immunoassays were weaker in all cases (r=0.407-0.574). Conclusion: In this longitudinal study, we established trimester-specific reference intervals for T4 and T3 by LC/MS/MS and compare these to intervals obtained by immunoassays. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:181 / 189
页数:9
相关论文
共 48 条
  • [21] Measurement of reference intervals for urinary free adrenal steroid levels in Japanese newborn infants by using stable isotope dilution gas chromatography/mass spectrometry
    Koyama, Yuhei
    Homma, Keiko
    Miwa, Masayuki
    Ikeda, Kazushige
    Murata, Mitsuru
    Hasegawa, Tomonobu
    CLINICA CHIMICA ACTA, 2013, 415 : 302 - 305
  • [22] SIMULTANEOUS ANALYSIS OF 7 STEROID HORMONES BY ISOTOPE-DILUTION LIQUID CHROMATOGRAPHY TANDEM MASS SPECTROMETRY (LC-MS/MS) AND ESTABLISHMENT OF NEW PEDIATRIC REFERENCE INTERVALS
    Kyriakopoulou, L.
    Yazdanpanah, M.
    Colantonio, D.
    Chan, M. K.
    Venner, A. A.
    Adeli, K.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S643 - S643
  • [23] Age-Specific reference intervals for ethanolamine plasmalogen species in red blood cells using liquid chromatography tandem mass spectrometry
    De Biase, I.
    Miller, M.
    Zuromski, L. M.
    Steckel, S.
    Vachali, P. P.
    Yuzyuk, T.
    CLINICAL CHEMISTRY, 2024, 70 : I203 - I203
  • [24] Development of a matrix-based candidate reference material for human glycated albumin using isotope-dilution liquid chromatography/tandem mass spectrometry
    Zhang, Rui
    Zhao, Rui
    Ren, Wenhua
    Wang, Mo
    Fan, Gaowei
    Shi, Jie
    Song, Yichuan
    Zhou, Xiaojie
    Wang, Qingtao
    ANALYTICA CHIMICA ACTA, 2023, 1239
  • [25] Development and evaluation of a candidate reference measurement procedure for the determination of progesterone in human serum using isotope-dilution liquid chromatography/tandem mass spectrometry
    Tai, Susan S. -C.
    Xu, Bei
    Welch, Michael J.
    ANALYTICAL CHEMISTRY, 2006, 78 (18) : 6628 - 6633
  • [26] Development and evaluation of a candidate reference measurement procedure for detecting 17α-hydroxyprogesterone in dried blood spots using isotope dilution liquid chromatography tandem mass spectrometry
    He, Ziyun
    Dai, Haibing
    Shen, Jian
    Huang, Yanjie
    Liu, Jinsong
    Yan, Renqing
    Zhang, Feng
    Yan, Shengkai
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2024, 416 (20) : 4635 - 4645
  • [27] Specific and sensitive quantification of folate vitamers in foods by stable isotope dilution assays using high-performance liquid chromatography-tandem mass spectrometry
    Achim Freisleben
    Peter Schieberle
    Michael Rychlik
    Analytical and Bioanalytical Chemistry, 2003, 376 : 149 - 156
  • [28] A rapid, sensitive method for the quantitation of specific metabolites of sulfur mustard in human urine using isotope-dilution gas chromatography-tandem mass spectrometry
    Young, CL
    Ash, D
    Driskell, WJ
    Boyer, AE
    Martinez, RA
    Silks, LA
    Barr, JR
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2004, 28 (05) : 339 - 345
  • [29] Specific and sensitive quantification of folate vitamers in foods by stable isotope dilution assays using high-performance liquid chromatography-tandem mass spectrometry
    Freisleben, A
    Schieberle, P
    Rychlik, M
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (02) : 149 - 156
  • [30] Development and evaluation of a reference measurement procedure for the determination of estradiol-17β in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry
    Tai, SSC
    Welsh, MJ
    ANALYTICAL CHEMISTRY, 2005, 77 (19) : 6359 - 6363