Cryoballoon pulmonary vein isolation temporarily modulates the intrinsic cardiac autonomic nervous system

被引:44
|
作者
Oswald, Hanno [1 ]
Klein, Gunnar [1 ]
Koenig, Thorben [1 ]
Luesebrink, Ulrich [1 ]
Duncker, David [1 ]
Gardiwal, Ajmal [1 ]
机构
[1] Hannover Med Sch, Dept Cardiovasc Med, D-30625 Hannover, Germany
关键词
Atrial fibrillation; Ablation; Cryoablation; Pulmonary vein isolation; Heart rate variability; CIRCUMFERENTIAL ABLATION; ATRIAL-FIBRILLATION; GANGLIONIC PLEXI; HEART-RATE; INITIATION; MECHANISM;
D O I
10.1007/s10840-010-9491-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Modulation of the intrinsic cardiac autonomic nervous system (ICANS) has been described to occur during radiofrequency pulmonary vein (PV) isolation for paroxysmal atrial fibrillation (AF) and has been controversially proposed to increase clinical success. Energy source used for PV isolation might influence ICANS modulation. The effect of balloon-delivered cryoenergy on the ICANS is unknown. We conducted a study investigating acute periprocedural effect on ICAN as well as changes in heart rate variability (HRV) for standard deviation of normal-to-normal intervals (SDNN) and triangular index (TI) as surrogates for ICANS modulation after cryoballoon PV isolation. Fourteen consecutive patients without structural heart disease underwent cryoballoon PV isolation for paroxysmal atrial fibrillation. Acute changes in heart rate requiring pacing during the procedure were recorded. HRV was tested by Holter ECG for SDNN and TI before ablation and after 1 week, 1 month, and 3 months following ablation. Fifty-five out of 56 PV were isolated (98%) with short-term 6-month freedom from paroxysmal AF of 64% by one single procedure. Five patients (36%) showed significant bradycardia during balloon thawing requiring temporary pacing. HRV decreased significantly immediately after PV isolation for both SDNN and TI until 1 month, gradually normalizing toward 3 months follow-up. HRV modulation was not different between patients with or without AF recurrences. Cryoballoon PV isolation significantly modulates the ICANS, but only temporarily for up to 3 months, measured by HRV changes after ablation.
引用
收藏
页码:57 / 62
页数:6
相关论文
共 50 条
  • [21] Cardiac autonomic regulation in patients undergoing pulmonary vein isolation for atrial fibrillation
    Styczkiewicz, Katarzyna
    Spadacini, Giammario
    Tritto, Massimo
    Perego, Giovanni B.
    Facchini, Mario
    Bilo, Grzegorz
    Kawecka-Jaszcz, Kalina
    Czarnecka, Danuta
    Malfatto, Gabriella
    Parati, Gianfranco
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2019, 20 (05) : 297 - 305
  • [22] "REDO" PULMONARY VEIN ISOLATION WITH THE CRYOBALLOON: IS IT TECHNICALLY FEASIBLE AND SAFE?
    Mondesert, B.
    Andrade, J. G.
    Clementy, N.
    Agustin, V.
    Macle, L.
    Rivard, L.
    Roy, D.
    Guerra, P. G.
    Talajic, M.
    Thibault, B.
    Khairy, P.
    Dubuc, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2012, 28 (05) : S113 - S113
  • [23] Cryoballoon pulmonary vein isolation: Effects on neural control of the heart
    Hanna, Peter
    Zhu, Ching
    Shivkumar, Kalyanam
    Buch, Eric
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 314 : 77 - 78
  • [24] Pulmonary vein isolation using an occluding cryoballoon for circumferential ablation
    Van Belle, Y.
    Thornton, A. S.
    Rivero-Ayerza, M.
    Jansse, P.
    Jordaens, L.
    EUROPEAN HEART JOURNAL, 2006, 27 : 42 - 43
  • [25] Vagal impact of cryoballoon ablation during pulmonary vein isolation
    Chang, Ting-Yung
    Lin, Chin-Yu
    Chen, Shih-Ann
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 265 : 132 - 133
  • [26] Breakage of a Circular Catheter Wedged in a Right Pulmonary Vein during Cryoballoon Pulmonary Vein Isolation
    Makimoto, Hisaki
    Kelm, Malte
    Shin, Dong-In
    Blockhaus, Christian
    INTERNAL MEDICINE, 2017, 56 (09) : 1057 - 1059
  • [27] An occluding cryoballoon for circumferential pulmonary vein isolation: feasibility and efficacy
    Van Belle, Y.
    Jansse, P.
    Rivero-Ayerza, M. J.
    Theuns, D. A. M. J.
    Jessurun, E. R.
    Jordaens, L.
    EUROPEAN HEART JOURNAL, 2007, 28 : 167 - 167
  • [28] Biophysical Indicators of Acute Pulmonary Vein Isolation With a Novel Cryoballoon
    Anic, Ante
    Martin, Andrew
    Breskovic, Toni
    Ouss, Alexandre
    Dekker, Lukas
    Sulkin, Matthew
    Binh Tran
    Yap, Sing-Chien
    Bhagwandien, Rohit E.
    Lever, Nigel
    Varma, Niraj
    CIRCULATION, 2020, 142
  • [29] Finding the right timing in cryoballoon ablation for pulmonary vein isolation
    Eickholt, C.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2018, 255 : 99 - 100
  • [30] Treating Atrial Fibrillation: Pulmonary Vein Isolation with the Cryoballoon Technique
    Jackson, Nick
    Barlow, Malcolm
    Leitch, James
    Attia, John
    HEART LUNG AND CIRCULATION, 2012, 21 (08): : 427 - 432