Cyclical testing of zone II flexor tendon repairs

被引:58
|
作者
Choueka, J [1 ]
Heminger, H [1 ]
Mass, DP [1 ]
机构
[1] Univ Chicago, Dept Orthopaed Surg, Chicago, IL 60637 USA
来源
关键词
flexor tendon repair; cyclical testing;
D O I
10.1053/jhsu.2000.20155
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Kessler, Strickland, or modified Becker repairs, all augmented with a running circumferential epitenon suture, were performed for simulated zone II flexor tendon lacerations in the index, long, and ring fingers of 12 fresh-frozen cadaveric specimens. Each hand was tested with a tensiometer built for curvilinear testing of human flexor tendons in an intact hand. Each tendon was cycled 100 times, then examined for gapping before testing to failure. Maximum load to failure, including tendon load and pinch force, was recorded for each tendon. We propose that combining the advantages of cyclical testing and a curvilinear model is the most effective way of testing flexor tendon repairs capable of undergoing an early active motion protocol. None of the repaired tendons failed during the cyclic portion of testing. The average gapping after cycling for the 3 suture techniques was 0.12 +/- 0.35 mm for the Kessler technique, 0.00 +/- 0.00 mm for the Strickland technique, and 0.19 +/- 0.26 mm for the modified Becker technique. The maximum tendon loads to failure were 33.8 +/- 6.8 N for the Kessler technique, 30.4 +/- 5.64 N for the Strickland technique, and 76.3 +/- 9.02 N for the modified Becker technique. There was a statistically significant difference between the modified Becker repair and the other 2 repa irs for maximum tendon load and pinch force to failure. The results of th is study show that a Il 3 tendon repair techniques can withstand forces reported with passive motion, but only the modified Becker repair allows sufficient strength above those forces that are estimated for active motion during tendon healing. Copyright (C) 2000 by the American Society for Surgery of the Hand.
引用
收藏
页码:1127 / 1134
页数:8
相关论文
共 50 条
  • [31] A biomechanical comparison of multistrand flexor tendon repairs using an in situ testing model
    Barrie, KA
    Wolfe, SW
    Shean, C
    Shenbagamurthi, D
    Slade, FF
    Panjabi, MM
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (03): : 499 - 506
  • [32] Flexor Tendon Repair in Zone II Augmented With an Externalized Detensioning Suture: Protected Flexor Tendon Repair
    Suszynski, Thomas M.
    Coutinho, Dominic
    Kaufmann, Robert A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2023, 48 (10): : 1065.e1 - 1065.e4
  • [33] A comparative study of two methods of controlled mobilization of flexor tendon repairs in zone 2
    Peck, FH
    Bücher, CA
    Watson, JS
    Roe, A
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1998, 23B (01): : 41 - 45
  • [34] Negative Predictors of Outcomes of Flexor Tendon Repairs
    Hurley, C. M.
    Reilly, Frank
    Callaghan, Simon
    Baig, M. N.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (03)
  • [35] Recent evolutions in flexor tendon repairs and rehabilitation
    Tang, Jin Bo
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2018, 43 (05) : 469 - 473
  • [36] THE EFFECT OF ULTRASOUND ON FLEXOR TENDON REPAIRS IN THE RABBIT
    ROBERTS, M
    RUTHERFORD, JH
    HARRIS, D
    HAND, 1982, 14 (01): : 17 - 20
  • [37] Flexor Tendon Repairs: Techniques, Eponyms, and Evidence
    Chauhan, Aakash
    Palmer, Bradley A.
    Merrell, Gregory A.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (09): : 1846 - 1853
  • [38] Is microsurgical experience essential in Zone II flexor tendon injuries?
    Pamuk, Cagdas
    JOINT DISEASES AND RELATED SURGERY, 2023, 34 (01): : 183 - 189
  • [39] Device for zone-II flexor tendon repair - Reply
    Su, BW
    Rosenwasser, MP
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (11): : 2591 - 2591
  • [40] Zone II tendon repairs augmented with autogenous dorsal tendon graft: A biomechanical analysis
    Slade, JF
    Bhargava, M
    Barrie, KA
    Shenbagamurthi, D
    Wolfe, SW
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2001, 26A (05): : 813 - 820