2D shear-wave ultrasound elastography (SWE) evaluation of ablation zone following radiofrequency ablation of liver lesions: is it more accurate?

被引:13
|
作者
Bo, Xiao W. [1 ,2 ]
Li, Xiao L. [1 ,2 ]
Xu, Hui X. [1 ,2 ,3 ]
Guo, Le H. [1 ,2 ]
Li, Dan D. [1 ,2 ]
Liu, Bo J. [1 ,2 ]
Wang, Dan [1 ,2 ]
He, Ya P. [1 ,2 ]
Xu, Xiao H. [3 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Med Ultrasound, Shanghai 200092, Peoples R China
[2] Tongji Univ, Sch Med, Ultrasound Res & Educ Inst, Shanghai 200092, Peoples R China
[3] Guangdong Med Coll, Affiliated Hosp, Dept Ultrasound, Zhanjiang, Peoples R China
来源
BRITISH JOURNAL OF RADIOLOGY | 2016年 / 89卷 / 1060期
关键词
CONTRAST-ENHANCED US; HEPATOCELLULAR-CARCINOMA; THERMAL ABLATION; VOLUME;
D O I
10.1259/bjr.20150852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the usefulness of two-dimensional quantitative ultrasound shear-wave elastography (2D-SWE) [i.e. virtual touch imaging quantification (VTIQ)] in assessing the ablation zone after radiofrequency ablation (RFA) for ex vivo swine livers. Methods: RFA was performed in 10 pieces of fresh ex vivo swine livers with a T20 electrode needle and 20-W output power. Conventional ultrasound, conventional strain elastography (SE) and VTIQ were performed to depict the ablation zone 0 min, 10 min, 30 min and 60 min after ablation. On VTIQ, the ablation zones were evaluated qualitatively by evaluating the shear-wave velocity (SWV) map and quantitatively by measuring the SWV. The ultrasound, SE and VTIQ results were compared against gross pathological and histopathological specimens. Results: VTIQ SWV maps gave more details about the ablation zone, the central necrotic zone appeared as red, lateral necrotic zone as green and transitional zone as light green, from inner to exterior, while the peripheral unablated liver appeared as blue. Conventional ultrasound and SE, however, only marginally depicted the whole ablation zone. The volumes of the whole ablation zone (central necrotic zone+lateral necrotic zone+transitional zone) and necrotic zone (central necrotic zone+lateral necrotic zone) measured by VTIQ showed excellent correlation (r=0.915, p < 0.001, and 0.856, p=0.002, respectively) with those by gross pathological specimen, whereas both conventional ultrasound and SE underestimated the volume of the whole ablation zone. The SWV values of the central necrotic zone, lateral necrotic zone, transitional zone and unablated liver parenchyma were 7.54-8.03 ms(-1), 5.13-5.28 ms(-1), 3.31-3.53 ms(-1) and 2.11-2.21 ms(-1), respectively (p, 0.001 for all the comparisons). The SWV value for each ablation zone did not change significantly at different observation times within an hour after RFA (all p > 0.05). Conclusion: The quantitative 2D-SWE of VTIQ is useful for the depiction of the ablation zone after RFA and it facilitates discrimination of different areas in the ablation zone qualitatively and quantitatively. This elastography technique might be useful for the therapeutic response evaluation instantly after RFA. Advances in knowledge: A new quantitative 2D-SWE (i.e. VTIQ) for evaluation treatment response after RFA is demonstrated. It facilitates discrimination of the different areas in the ablation zone qualitatively and quantitatively and may be useful for the therapeutic response evaluation instantly after RFA in the future.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] High risk of misclassifying liver stiffness using 2D shear-wave and transient elastography during a moderate or high calorie meal
    Kjaergaard, Maria
    Thiele, Maja
    Madsen, Bjorn S.
    Jansen, Christian
    Trebicka, Jonel
    Krag, Aleksander
    HEPATOLOGY, 2015, 62 : 594A - 595A
  • [42] 2D-Shear Wave Elastography in the Evaluation of Parathyroid Lesions in Patients with Hyperparathyroidism\
    Golu, Ioana
    Sporea, Ioan
    Moleriu, Lavinia
    Tudor, Anca
    Cornianu, Marioara
    Vlad, Adrian
    Timar, Romulus
    Balas, Melania
    Amzar, Daniela
    Vlad, Mihaela
    INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2017, 2017
  • [43] The novel point shear-wave elastography method ElastPQ® is accurate for non-invasive evaluation of liver fibrosis and portal hypertension
    Bucsics, T.
    Grasl, B.
    Schwabl, P.
    Mandorfer, M.
    Dmitrieva, J.
    Peck-Radosavljevic, M.
    Trauner, M.
    Sieghart, W.
    Ferlitsch, A.
    Reiberger, T.
    JOURNAL OF HEPATOLOGY, 2017, 66 (01) : S674 - S674
  • [44] Application of 3D and 2D quantitative shear wave elastography (SWE) to differentiate between benign and malignant breast masses
    Jie Tian
    Qianqi Liu
    Xi Wang
    Ping Xing
    Zhuowen Yang
    Changjun Wu
    Scientific Reports, 7
  • [45] Application of 3D and 2D quantitative shear wave elastography (SWE) to differentiate between benign and malignant breast masses
    Tian, Jie
    Liu, Qianqi
    Wang, Xi
    Xing, Ping
    Yang, Zhuowen
    Wu, Changjun
    SCIENTIFIC REPORTS, 2017, 7
  • [46] Diagnostic Performance of 2D Shear Wave (2D-SWE) for Liver Fibrosis in Adults Undergoing Bariatric Surgery
    Ana L. Alcantara-Diaz
    Jaime F. Ruiz-Fernandez
    Jorge L. Salazar-Alarcon
    Gustavo Salinas-Sedo
    Carlos J. Toro-Huamanchumo
    Obesity Surgery, 2023, 33 : 3120 - 3126
  • [47] High risk of misinterpreting liver and spleen stiffness using 2D shear-wave and transient elastography after a moderate or high calorie meal
    Kjaergaard, Maria
    Thiele, Maja
    Jansen, Christian
    Madsen, Bjom Staehr
    Goertzen, Jan
    Strassburg, Christian
    Trebicka, Jonel
    Krag, Aleksander
    PLOS ONE, 2017, 12 (04):
  • [48] INTEROBSERVER REPRODUCIBILITY OF A 2D-SHEAR WAVE ELASTOGRAPHY (2D-SWE) TECHNIQUE AND THE IMPACT OF ULTRASOUND EXPERIENCE IN ACHIVIENG RELIABLE DATA
    Moga, T. V.
    Stepan, A. M.
    Pienar, C.
    Popescu, A.
    Sirli, R.
    Danila, M.
    Sporea, I.
    JOURNAL OF HEPATOLOGY, 2016, 64 : S740 - S741
  • [49] Diagnostic Performance of 2D Shear Wave (2D-SWE) for Liver Fibrosis in Adults Undergoing Bariatric Surgery
    Alcantara-Diaz, Ana L.
    Ruiz-Fernandez, Jaime F.
    Salazar-Alarcon, Jorge L.
    Salinas-Sedo, Gustavo
    Toro-Huamanchumo, Carlos J.
    OBESITY SURGERY, 2023, 33 (10) : 3120 - 3126
  • [50] Understanding confounding factors allows for accurate interpretation of liver stiffness measurements by ElastQ, a novel 2D shear wave elastography technique
    Bauer, David J. M.
    De Silvestri, Annalisa
    Maiocchi, Laura
    Raimondi, Ambra
    Mare, Ruxandra
    Mandorfer, Mattias
    Sporea, Ioan
    Muellner-Bucsics, Theresa
    Ferraioli, Giovanna
    Reiberger, Thomas
    ULTRASCHALL IN DER MEDIZIN, 2024,