2D shear-wave ultrasound elastography (SWE) evaluation of ablation zone following radiofrequency ablation of liver lesions: is it more accurate?

被引:13
|
作者
Bo, Xiao W. [1 ,2 ]
Li, Xiao L. [1 ,2 ]
Xu, Hui X. [1 ,2 ,3 ]
Guo, Le H. [1 ,2 ]
Li, Dan D. [1 ,2 ]
Liu, Bo J. [1 ,2 ]
Wang, Dan [1 ,2 ]
He, Ya P. [1 ,2 ]
Xu, Xiao H. [3 ]
机构
[1] Tongji Univ, Sch Med, Shanghai Peoples Hosp 10, Dept Med Ultrasound, Shanghai 200092, Peoples R China
[2] Tongji Univ, Sch Med, Ultrasound Res & Educ Inst, Shanghai 200092, Peoples R China
[3] Guangdong Med Coll, Affiliated Hosp, Dept Ultrasound, Zhanjiang, Peoples R China
来源
BRITISH JOURNAL OF RADIOLOGY | 2016年 / 89卷 / 1060期
关键词
CONTRAST-ENHANCED US; HEPATOCELLULAR-CARCINOMA; THERMAL ABLATION; VOLUME;
D O I
10.1259/bjr.20150852
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the usefulness of two-dimensional quantitative ultrasound shear-wave elastography (2D-SWE) [i.e. virtual touch imaging quantification (VTIQ)] in assessing the ablation zone after radiofrequency ablation (RFA) for ex vivo swine livers. Methods: RFA was performed in 10 pieces of fresh ex vivo swine livers with a T20 electrode needle and 20-W output power. Conventional ultrasound, conventional strain elastography (SE) and VTIQ were performed to depict the ablation zone 0 min, 10 min, 30 min and 60 min after ablation. On VTIQ, the ablation zones were evaluated qualitatively by evaluating the shear-wave velocity (SWV) map and quantitatively by measuring the SWV. The ultrasound, SE and VTIQ results were compared against gross pathological and histopathological specimens. Results: VTIQ SWV maps gave more details about the ablation zone, the central necrotic zone appeared as red, lateral necrotic zone as green and transitional zone as light green, from inner to exterior, while the peripheral unablated liver appeared as blue. Conventional ultrasound and SE, however, only marginally depicted the whole ablation zone. The volumes of the whole ablation zone (central necrotic zone+lateral necrotic zone+transitional zone) and necrotic zone (central necrotic zone+lateral necrotic zone) measured by VTIQ showed excellent correlation (r=0.915, p < 0.001, and 0.856, p=0.002, respectively) with those by gross pathological specimen, whereas both conventional ultrasound and SE underestimated the volume of the whole ablation zone. The SWV values of the central necrotic zone, lateral necrotic zone, transitional zone and unablated liver parenchyma were 7.54-8.03 ms(-1), 5.13-5.28 ms(-1), 3.31-3.53 ms(-1) and 2.11-2.21 ms(-1), respectively (p, 0.001 for all the comparisons). The SWV value for each ablation zone did not change significantly at different observation times within an hour after RFA (all p > 0.05). Conclusion: The quantitative 2D-SWE of VTIQ is useful for the depiction of the ablation zone after RFA and it facilitates discrimination of different areas in the ablation zone qualitatively and quantitatively. This elastography technique might be useful for the therapeutic response evaluation instantly after RFA. Advances in knowledge: A new quantitative 2D-SWE (i.e. VTIQ) for evaluation treatment response after RFA is demonstrated. It facilitates discrimination of the different areas in the ablation zone qualitatively and quantitatively and may be useful for the therapeutic response evaluation instantly after RFA in the future.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Liver Stiffness Measurements by 2D Shear-Wave Elastography: Effect of Steatosis on Fibrosis Evaluation
    Kumada, Takashi
    Toyoda, Hidenori
    Yasuda, Satoshi
    Ogawa, Sadanobu
    Gotoh, Tatsuya
    Ito, Takanori
    Tada, Toshifumi
    Tanaka, Junko
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 219 (04) : 604 - 612
  • [2] Role of shear-wave elastography (SWE) in complex cystic and solid breast lesions in comparison with conventional ultrasound
    Lee, Bo Eun
    Chung, Jin
    Cha, Eun-Suk
    Lee, Jee Eun
    Kim, Jeoung Hyun
    EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (07) : 1236 - 1241
  • [3] Cardiac shear-wave elastography using a transesophageal transducer: application to the mapping of thermal lesions in ultrasound transesophageal cardiac ablation
    Kwiecinski, Wojciech
    Bessiere, Francis
    Colas, Elodie Constanciel
    N'Djin, W. Apoutou
    Tanter, Mickael
    Lafon, Cyril
    Pernot, Mathieu
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (20): : 7829 - 7846
  • [4] Evaluation of liver lesions by use of shear wave elastography and computed tomography perfusion imaging after radiofrequency ablation in clinically normal dogs
    Lee, Dahae
    Park, Seungjo
    Ang, Mary Jasmin C.
    Park, Jun-Gyu
    Yoon, Sooa
    Kim, Cheolhyun
    Lee, Sang-Kwon
    Cho, Kyoung-Oh
    Choi, Jihye
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2018, 79 (11) : 1140 - 1149
  • [5] Quantitative evaluation of atrial radio frequency ablation using intracardiac shear-wave elastography
    Kwiecinski, Wojciech
    Provost, Jean
    Dubois, Remi
    Sacher, Frederic
    Haissaguerre, Michel
    Legros, Mathieu
    An Nguyen-Dinh
    Dufait, Remi
    Tanter, Mickael
    Pernot, Mathieu
    MEDICAL PHYSICS, 2014, 41 (11)
  • [6] Liver Stiffness Measured by Two-Dimensional Shear-Wave Elastography: Prognostic Value after Radiofrequency Ablation for Hepatocellular Carcinoma
    Lee, Dong Ho
    Lee, Jeong Min
    Yoon, Jung-Hwan
    Kim, Yoon Jun
    Lee, Jeong-Hoon
    Yu, Su Jong
    Han, Joon Koo
    LIVER CANCER, 2018, 7 (01) : 65 - 75
  • [7] The evaluation of the use of 2D shear-wave ultrasound elastography in differentiation of clinically insignificant and significant liver fibrosis in pediatric age group
    Akyuz, Melih
    Gurcan Kaya, Neslihan
    Esendagli, Guldal
    Dalgic, Buket
    Ozhan Oktar, Suna
    ABDOMINAL RADIOLOGY, 2021, 46 (05) : 1941 - 1946
  • [8] The evaluation of the use of 2D shear-wave ultrasound elastography in differentiation of clinically insignificant and significant liver fibrosis in pediatric age group
    Melih Akyuz
    Neslihan Gurcan Kaya
    Guldal Esendagli
    Buket Dalgic
    Suna Ozhan Oktar
    Abdominal Radiology, 2021, 46 : 1941 - 1946
  • [9] EVALUATION OF MICROWAVE ABLATION EFFICACY BY STRAIN ELASTOGRAPHY AND SHEAR WAVE ELASTOGRAPHY IN EX VIVO PORCINE LIVER
    Luo, Chunyue
    Li, Tao
    Li, Zuojia
    Zuo, Yanling
    He, Guangmin
    Lin, Jianying
    Liu, Guancheng
    Dai, Lu
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (09): : 2636 - 2645
  • [10] Evaluation of 2D-Shear Wave Elastography for Characterisation of Focal Liver Lesions
    Gerber, Ludmila
    Fitting, Daniel
    Srikantharajah, Kajana
    Weiler, Nina
    Kyriakidou, Georgia
    Bojunga, Joerg
    Schulze, Falko
    Bone, Dimitra
    Zeuzem, Stefan
    Friedrich-Rust, Mireen
    JOURNAL OF GASTROINTESTINAL AND LIVER DISEASES, 2017, 26 (03) : 283 - 290