Configuration of the ion exchange chromatography, hydrophilic interaction chromatography, and reversed-phase chromatography as off-line three-dimensional chromatography coupled with high-resolution quadrupole-Orbitrap mass spectrometry for the multicomponent characterization of Uncaria sessilifructus

被引:36
|
作者
Feng, Keyu [1 ,2 ]
Wang, Simiao [1 ,2 ]
Han, Lifeng [1 ,2 ]
Qian, Yuexin [1 ,2 ]
Li, Huifang [3 ]
Li, Xue [1 ,2 ]
Jia, Li [1 ,2 ]
Hu, Ying [1 ]
Wang, Huimin [1 ,2 ]
Liu, Meiyu [1 ,2 ]
Hu, Wandi [1 ,2 ]
Guo, Dean [1 ]
Yang, Wenzhi [1 ,2 ]
机构
[1] Tianjin Univ Tradit Chinese Med, State Key Lab Component Based Chinese Med, 10 Poyanghu Rd, Tianjin 301617, Peoples R China
[2] Tianjin Univ Tradit Chinese Med, Tianjin Key Lab TCM Chem & Anal, 10 Poyanghu Rd, Tianjin 301617, Peoples R China
[3] Thermo Fisher Sci, Bldg 6,27 Xinjinqiao Rd, Shanghai 201206, Peoples R China
基金
中国国家自然科学基金;
关键词
Three-dimensional liquid chromatography; Quadrupole-Orbitrap mass spectrometry; Uncaria sessilifructus; Alkaloid; Triterpenic acid; LIQUID; IDENTIFICATION; ONLINE; QUANTIFICATION; ACQUISITION; SEPARATION; DISCOVERY; STRATEGY; GINSENG; STEMS;
D O I
10.1016/j.chroma.2021.462237
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Herbs represent complex chemical systems involving various primary and secondary metabolites that are featured by large spans of acid-base property, polarity, molecular mass, and content, etc. , which thus poses great challenges to characterize the metabolites contained. Here, the combination of multiple mechanism chromatography coupled with improved data-dependent-MS2 acquisition (DDA-MS2) is presented as a strategy to support the deep metabolites characterization. Targeting Uncaria sessilifructus, a reputable medicinal herb containing alkaloids and triterpenic acids (TAs) as the main pharmacologically bioactive ingredients, a three-dimensional liquid chromatography (3D-LC) system was established by integrating ion exchange chromatography, hydrophilic interaction chromatography, and reversed-phase chromatography (IEC-HILIC-RPC). The first-dimensional chromatography, configuring a PhenoSphere SCX column eluted by methanol/20 mM ammonium acetate-0.05% formic acid in water, could well fractionate the total extract into two fractions (unretained ingredients and alkaloids). The subsequent HILIC using an XAmide column and RPC by a CSH Phenyl-Hexyl column achieved the sufficient resolution of the total TAs and total alkaloids, respectively. A polarity-switching precursor ions list-including DDA approach by Q-Orbitrap-MS enabled the high-efficiency, coverage-enhanced identification of alkaloids and TAs. This 3D-LC/Q-Orbitrap-MS system was validated as precise (RSD < 5% for intra-day/inter-day precision), Up to 308 components were separated from U. sessilifructus, and 128 thereof (including 85 alkaloids, 29 TAs, and 14 others) were identified or tentatively characterized, exhibiting superiority over the conventional one-dimensional LC/MS. Conclusively, 3D-LC/MS in an off-line mode can facilitate the flexible configuration of multiple chromatography to accomplish the fit-for-purpose characterization of the metabolites from an herbal extract or a biosample. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Simultaneously targeted and untargeted multicomponent characterization of Erzhi Pill by offline two-dimensional liquid chromatography/quadrupole-Orbitrap mass spectrometry
    Fu, Ling-ling
    Ding, Hui
    Han, Li-feng
    Jia, Li
    Yang, Wen-zhi
    Zhang, Chun-xia
    Hu, Ying
    Zuo, Tian-tian
    Gao, Xiu-mei
    Guo, De-an
    JOURNAL OF CHROMATOGRAPHY A, 2019, 1584 : 87 - 96
  • [22] Analysis of phthalates in milk and milk products by liquid chromatography coupled to quadrupole Orbitrap high-resolution mass spectrometry
    Jia, Wei
    Chu, Xiaogang
    Ling, Yun
    Huang, Junrong
    Chang, James
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1362 : 110 - 118
  • [23] Metabonomics study of the acute graft rejection in rat renal transplantation using reversed-phase liquid chromatography and hydrophilic interaction chromatography coupled with mass spectrometry
    Chen, Jihong
    Wen, Hao
    Liu, Jian
    Yu, Che
    Zhao, Xinjie
    Shi, Xianzhe
    Xu, Guowang
    MOLECULAR BIOSYSTEMS, 2012, 8 (03) : 871 - 878
  • [24] Chemical composition analysis of pomegranate seeds based on ultra-high-performance liquid chromatography coupled with quadrupole-Orbitrap high-resolution mass spectrometry
    Li, Guoping
    Chen, Meng
    Chen, Jing
    Shang, Yuhan
    Lian, Xianhui
    Wang, Penglong
    Lei, Haimin
    Ma, Qiang
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 187
  • [25] Comprehensive impurity profiling of nutritional infusion solutions by multidimensional off-line reversed-phase liquid chromatography x hydrophilic interaction chromatography-ion trap mass-spectrometry and charged aerosol detection with universal calibration
    Schiesel, Simone
    Laemmerhofer, Michael
    Lindner, Wolfgang
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1259 : 100 - 110
  • [26] Unveiling the complexity of Astragali Radix by comprehensive two-dimensional hydrophilic interaction liquid chromatography x reversed phase liquid chromatography system coupled to hybrid linear ion trap Orbitrap mass spectrometry
    Hua, Shiyao
    Liu, Jiayue
    Pu, Sijia
    Zou, Liang
    Zhang, Lei
    Li, Peng
    MICROCHEMICAL JOURNAL, 2025, 210
  • [27] Off-line comprehensive 2-dimensional hydrophilic interaction x reversed phase liquid chromatography analysis of procyanidins
    Kalili, Kathithileni M.
    de Villiers, Andre
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (35) : 6274 - 6284
  • [28] Sequential Hybrid Three-Dimensional Gas Chromatography with Accurate Mass Spectrometry: A Novel Tool for High-Resolution Characterization of Multicomponent Samples
    Yan, Dandan
    Wong, Yong Foo
    Whittock, Simon P.
    Koutoulis, Anthony
    Shellie, Robert A.
    Marriott, Philip J.
    ANALYTICAL CHEMISTRY, 2018, 90 (08) : 5264 - 5271
  • [29] Nontargeted Lipidomic Characterization of Porcine Organs Using Hydrophilic Interaction Liquid Chromatography and Off-Line Two-Dimensional Liquid Chromatography-Electrospray Ionization Mass Spectrometry
    Cifkova, Eva
    Holcapek, Michal
    Lisa, Miroslav
    LIPIDS, 2013, 48 (09) : 915 - 928
  • [30] Comprehensive Two-Dimensional Hydrophilic Interaction Chromatography (HILIC) x Reversed-Phase Liquid Chromatography Coupled to High-Resolution Mass Spectrometry (RP-LC-UV-MS) Analysis of Anthocyanins and Derived Pigments in Red Wine
    Willemse, Chandre M.
    Stander, Maria A.
    Vestner, Jochen
    Tredoux, Andreas G. J.
    de Villiers, Andre
    ANALYTICAL CHEMISTRY, 2015, 87 (24) : 12006 - 12015