Photon dose calculation analysis of a varian treatment planning system algorithm on a siemens linear accelerator in inhomogeneous media

被引:0
|
作者
Finlay, J. [1 ]
Mesina, C. [1 ]
机构
[1] Univ Penn, Philadelphia, PA 19104 USA
关键词
D O I
10.1118/1.2761009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the accuracy of photon dose calculations in inhomogeneous media using the analytical anisotropic algorithm (AAA) and pencil beam convolution (PBC) implemented in Varian Medical Systems' Eclipse treatment planning system with Siemens linear accelerators. Method and Materials: Using a 0.125 cm3 ionization chamber in a 3‐layer phantom with cork between water‐equivalent layers, we measured absolute depth doses (DD) for 6 and 15 MV, and 3, 5, 10, and 20 cm square fields. To assess lateral disequilibrium modeling, we irradiated another phantom in which the middle cork layer extended laterally only 2.5 cm beyond the central axis, the remainder of the layer being plastic with 10 and 20 cm square fields. Dose profiles were measured using EDR2 film placed at three depths and with a diode detector array placed in the bottom layer. Calculations were performed using AAA and PBC with inhomogeneity correction in Eclipse. Results: For both 6 and 15 MV, the DD calculated by AAA and PBC agreed with measurement within 2% and 3%, respectively proximal to the inhomogeneity beyond the buildup region. Within the inhomogeneity, the agreement was better than 6% for large fields, however, both algorithms overestimated the dose by up to 20% (AAA) or 55% (PBC) for the 3‐cm 6MV field. Distal to the inhomogeneity, AAA modeled the shape of the buildup more accurately than PBC. Lateral profiles indicated that the shape of the penumbra in the inhomogeneous region and the perturbation at the vertical interface predicted by AAA agreed with film and diode array measurements better than PBC. Conclusion: AAA offered an overall improvement over PBC in inhomogeneous media, particularly for small fields and in interface and buildup regions. The overestimate of dose within the inhomogeneity for small fields motivates further investigation, particularly if AAA is used for IMRT calculations in lung. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2481 / 2481
页数:1
相关论文
共 50 条
  • [1] IMRT planning based on various photon dose calculation techniques at inhomogeneous media
    Scholz, C
    Oelfke, U
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 2071 - 2071
  • [2] Comparison of Dose Based and Biological Based Treatment Planning Systems for the Siemens Artiste Linear Accelerator
    Day, E.
    Gayou, O.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [3] Comprehensive Validation of the Electron Monte Carlo Dose Calculation Algorithm in RayStation Treatment Planning System for An Elekta Linear Accelerator with AgilityTM Treatment Head
    Wang, Yi
    Park, Yang-Kyun
    Doppke, Karen P.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3382 - 3382
  • [4] Preliminary results from anisotropic analytical algorithm for photon dose calculation on Siemens and Elekta linear accelerators
    Cozzi, L.
    Glashoerster, M.
    Nicolini, G.
    Seelentag, W.
    Fogliata, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S30 - S30
  • [5] Photon Beam Modeling and Verification of Collapsed Cone Convolution Algorithm for Dose Calculation in a Radiation Treatment Planning System
    Jung, J.
    Cho, W.
    Lee, J.
    Kim, D.
    Kim, M.
    Suh, T.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3829 - 3829
  • [6] A Practical Method to Measure and Evaluate Different Dose Calculation Algorithms in Varian Eclipse Treatment Planning System
    Lu, L.
    Yembi-Goma, G.
    Wang, J.
    Gupta, N.
    Li, K.
    Zhang, H.
    Weldon, M.
    Huang, Z.
    Lo, S.
    Martin, D.
    Mayr, N.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [7] COMMISSIONING OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR 6 MV AND 15 MV PHOTON BEAMS FROM A 160 MLC SIEMENS ACCELERATOR
    Zucca Aparicio, D.
    Perez Moreno, J. M.
    Fernandez-Leton, P.
    Garcia Ruiz-Zorrilla, J.
    Minambres, A.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S521 - S522
  • [8] Photon dose calculations in homogeneous media for a treatment planning system using a collapsed cone superposition convolution algorithm
    Lydon, JM
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (06): : 1813 - 1822
  • [9] Comparison of 4MV photon surface dose among Varian, Siemens, and Elekta linear accelerators for tangential breast treatment: A phantom study
    Yamaguchi S.
    Karasawa K.
    Furuya T.
    Fujita T.
    Tutumi Y.
    Miura K.
    Takada T.
    Ito K.
    Ozawa S.
    [J]. Radiation Medicine, 2007, 25 (1): : 8 - 13
  • [10] Linear accelerator dose output difference to dose table and treatment planning system in recent years in Finland
    Niemela, J.
    Sipila, P.
    Bly, R.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S139 - S140