Diagnosis and management of iatrogenic cardiac perforation caused by pacemaker and defibrillator leads

被引:46
|
作者
Rajkumar, Christopher A. [1 ]
Claridge, Simon [2 ]
Jackson, Tom [2 ]
Behar, Jonathan [2 ]
Johnson, Jonathan [2 ]
Sohal, Manav [2 ]
Amraoui, Sana [1 ]
Nair, Arjun [3 ]
Preston, Rebecca [3 ]
Gill, Jaswinder [1 ]
Rajani, Ronak [1 ,3 ]
Rinaldi, Christopher A. [1 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Dept Cardiol, London, England
[2] Kings Coll London, Dept Imaging Sci, London, England
[3] Guys & St Thomas NHS Fdn Trust, Dept Cardiac Comp Tomog, London, England
来源
EUROPACE | 2017年 / 19卷 / 06期
关键词
Cardiac perforation diagnosis; Transthoracic echocardiography; Computed tomography; Pacemaker; Lead extraction; RIGHT-VENTRICULAR PERFORATION; REVISION;
D O I
10.1093/europace/euw074
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Cardiac perforations caused by pacemaker or implantable cardioverter-defibrillator (ICD) leads are uncommon but potentially fatal events. The optimal approach to such cases is unclear. The aim of this study was to identify the optimal imaging modality and management strategy for cardiac perforation. Methods and results All patients presenting to a single institution with cardiac perforation >24 h since implant between 2011 and 2015 were identified retrospectively. Assessment of the diagnostic performance of pre-extraction chest radiography, transthoracic echocardiography (TTE), and computed tomography (CT) was carried out by blinded review. The method of lead extraction and any associated complications were examined. Eighteen cases of cardiac perforation were identified from 426 lead extraction procedures. Sixteen patients had abnormal electrical parameters at device interrogation. In all cases, the perforating lead was an active fixation model, and in four cases, this was an ICD coil. The accuracy of CT imaging for the diagnosis of cardiac perforation was 92.9%, with sensitivity and specificity of 100 and 85.7%, respectively. This was superior to both TTE (accuracy 62.7%, sensitivity and specificity 41.2 and 84.2%, respectively) and chest radiography (accuracy 61.1%, sensitivity and specificity 27.7 and 94.4%, respectively). Transvenous lead extraction (TLE) was performed in 17 patients, and a hybrid surgical approach in 1 patient. Of those who underwent TLE, there was 100% complete procedural success as per Heart Rhythm Society definitions. Conclusion In the setting of cardiac perforation, CT is the imaging modality of choice. Transvenous lead extraction can be recommended as a safe, efficacious, and versatile intervention.
引用
收藏
页码:1031 / 1037
页数:7
相关论文
共 50 条
  • [1] Iatrogenic cardiac perforation due to pacemaker and defibrillator leads: a contemporary multicentre experience
    Waddingham, Peter H.
    Elliott, James
    Bates, Alexander
    Bilham, James
    Muthumala, Amal
    Honarbakhsh, Shohreh
    Ullah, Waqas
    Hunter, Ross J.
    Lambiase, Pier D.
    Lane, Rebecca E.
    Chow, Anthony W. C.
    EUROPACE, 2022, 24 (11): : 1824 - 1833
  • [2] Management of iatrogenic atrial perforation caused by pacemaker electrodes: a case report
    Fiorillo, Graziano
    Ghazihosseini, Seyedali
    Agizza, Simone
    Lanza, Francesco
    Piccirillo, Simona
    Gargiulo, Giuseppe
    Gargiulo, Paola
    Pinna, Giovanni Battista
    Pilato, Emanuele
    De Rosa, Carlo
    Morisco, Carmine
    Esposito, Giovanni
    JOURNAL OF MEDICAL CASE REPORTS, 2024, 18 (01)
  • [3] Cardiac chambers perforation by pacemaker and cardioverter-defibrillator leads. Own experience in diagnosis, treatment and preventive methods
    Maziarz, Andrzej
    Zabek, Andrzej
    Malecka, Barbara
    Kutarski, Andrzej
    Lelakowski, Jacek
    KARDIOLOGIA POLSKA, 2012, 70 (05) : 508 - 510
  • [4] Incidence, Management, and Prevention of Right Ventricular Perforation by Pacemaker and Implantable Cardioverter Defibrillator Leads
    Migliore, Federico
    Zorzi, Alessandro
    Bertaglia, Emanuele
    Leoni, Loira
    Siciliano, Mariachiara
    De Lazzari, Manuel
    Ignatiuk, Barbara
    Veronese, Marta
    Verlato, Roberto
    Tarantini, Giuseppe
    Iliceto, Sabino
    Corrado, Domenico
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2014, 37 (12): : 1602 - 1609
  • [5] Management of arterial injuries caused by laser extraction of indwelling venous pacemaker and defibrillator leads
    Lawton, Jennifer S.
    Moon, Marc R.
    Curci, John A.
    Rubin, Brian G.
    Smith, Timothy W.
    Gleva, Marye J.
    Damiano, Ralph J., Jr.
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (08): : 917 - 920
  • [6] Delayed cardiac tamponade by iatrogenic aortic perforation with pacemaker implantation
    Sticco, CC
    Barrett, LO
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (02): : 480 - 481
  • [7] Ventricular perforation by pacemaker leads: Diagnosis by computed tomography
    Awamleh Garcia, P.
    Talavera Calle, P.
    RADIOLOGIA, 2014, 56 (05): : 472 - 474
  • [8] Role of the echocardiography laboratory in diagnosis and management of pacemaker and implantable cardiac defibrillator infection
    Kerut, Edmund Kenneth
    Hanawalt, Curtis
    Everson, Charles T.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (09): : 1008 - 1012
  • [9] Subclinical cardiac perforation caused by a Micra leadless pacemaker
    Togashi, Ikuko
    Sato, Toshiaki
    Hoshida, Kyoko
    Soejima, Kyoko
    JOURNAL OF ARRHYTHMIA, 2018, 34 (03) : 326 - 328
  • [10] Diagnosis and surgical management of iatrogenic esophageal perforation
    Wendl, K
    Fernandez, FF
    Hofheinz, H
    Richter, A
    Lorenz, D
    Manegold, BC
    2ND EUROPEAN CONGRESS OF TRAUMA AND EMERGENCY SURGERY, 1997, : 19 - 22