Control of Passing the Resonance Zone During Start-up of Above Resonance Vibration Machines

被引:0
|
作者
Nozhenko, Viktoriia [1 ]
Rodkin, Dmytro [1 ]
Bohatyrov, Kostyantin [2 ]
机构
[1] Kremenchuk Mykhailo Ostrohradskyi Natl Univ, Syst Automat Control & Elect Drive Dept, Kremenchuk, Ukraine
[2] PJSC Poltava Min & Concentrating Combine, Gorishni Plavni, Ukraine
关键词
vibration machine; induction motor; starting mode; resonance zone; frequency-controlled electric drive;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The features of the start-up of the electric drive of an above resonance vibration machine were considered. The possibility of using a variable-frequency electric drive to pass the resonance zone while starting the vibration machine was substantiated. It was noted that in the case of using drive motors in above resonance vibration machine with a capacity calculated for a stable operation, it is necessary to ensure an increase in the torque of the motors while overcoming the resonant zone. To increase the torque of the drive motors during the start-up process, the use of a linear law of frequency control and a sharp steplike increase in the supply voltage when approaching the resonance zone was proposed. Experimental studies of the formation of the frequency start-up of above resonance vibration machines in a laboratory setup were carried out.
引用
收藏
页码:146 / 149
页数:4
相关论文
共 50 条
  • [21] On the periodic images of start-up in repetitive control
    Longman, Richard W.
    Bao, Jiangcheng
    SPACE FLIGHT MECHANICS 2007, VOL 127, PTS 1 AND 2, 2007, 127 : 1743 - +
  • [22] CONTROL ISSUES RELATED TO START-UP OF TOKAMAKS
    Jackson, G. L.
    Humphreys, D. A.
    Hyatt, A. W.
    Leuer, J. A.
    FUSION SCIENCE AND TECHNOLOGY, 2011, 59 (03) : 621 - 622
  • [23] NONSTATIONARY VIBRATION OF A SYSTEM WITH BACKLASH PASSING THROUGH A RESONANCE
    YANABE, S
    TOKUHASHI, H
    TAMURA, A
    BULLETIN OF THE JSME-JAPAN SOCIETY OF MECHANICAL ENGINEERS, 1986, 29 (248): : 533 - 540
  • [24] Kinetics of Wood Devolatilization during Start-up
    Baumgarten, Bjoern
    Reinhardt, Jannis
    Lepski, Carola
    Risio, Benedetto
    Thorwarth, Harald
    ENERGY & FUELS, 2019, 33 (11) : 11285 - 11291
  • [25] Electrostatic Vibration Energy Harvester with Piezoelectric Start-up Generator
    Florentino, Helder R.
    Freire, Raimundo C. S.
    Sa, Alan V. S.
    Florentino, Caio
    Galayko, Dimitri
    2011 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2011, : 1343 - 1346
  • [26] Vibration fault detection method for turbopump in start-up process
    Xia, Lu-Rui
    Hu, Niao-Qing
    Qin, Guo-Jun
    Li, Jian-Chuan
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2010, 25 (03): : 704 - 708
  • [27] Control Algorithm Design For Passing Through Resonance Of Two-Rotor Vibration Unit
    Fradkov, Alexander L.
    Tomchin, Dmitry A.
    Chuev, Dmitry Yu.
    2008 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, VOLS 1 AND 2, 2008, : 188 - 193
  • [28] Water circulation control during once-through boiler start-up
    Eitelberg, E
    Boje, E
    CONTROL ENGINEERING PRACTICE, 2004, 12 (06) : 677 - 685
  • [29] Control of electron acceleration process during merging start-up of spherical tokamak
    Inomoto, M.
    Mihara, T.
    Kondo, K.
    Kaneko, H.
    Kusano, K.
    Kaneko, K.
    Maeda, Y.
    Shinohara, A.
    Jin, H.
    Suzuki, T.
    Tanabe, H.
    Ono, Y.
    Kamio, S.
    Kawamori, E.
    NUCLEAR FUSION, 2021, 61 (11)
  • [30] Hybrid adaptive resonance control using speed gradient approach for vibration machines
    Efimov, D. V.
    Fradkov, A. L.
    2007 AMERICAN CONTROL CONFERENCE, VOLS 1-13, 2007, : 881 - +