ESIPT-based ratiometric fluorescence probe for the intracellular imaging of peroxynitrite

被引:99
|
作者
Wu, Luling [1 ]
Wang, Yang [2 ,3 ]
Weber, Maria [1 ]
Liu, Liyuan [1 ]
Sedgwick, Adam C. [1 ]
Bull, Steven D. [1 ]
Huang, Chusen [2 ,3 ]
James, Tony D. [1 ,4 ]
机构
[1] Univ Bath, Dept Chem, Bath BA2 7AY, Avon, England
[2] Shanghai Normal Univ, Educ Minist, Key Lab Resource Chem, Shanghai Key Lab Rare Earth Funct Mat, 100 Guilin Rd, Shanghai 200234, Peoples R China
[3] Shanghai Normal Univ, Shanghai Municipal Educ Comm, Key Lab Mol Imaging Probes & Sensors, Dept Chem, 100 Guilin Rd, Shanghai 200234, Peoples R China
[4] Sophia Univ, Fac Sci & Technol, Dept Mat & Life Sci, Chiyoda Ku, 7-1 Kioi Cho, Tokyo 1028554, Japan
关键词
INTRAMOLECULAR PROTON-TRANSFER; ENDOPLASMIC-RETICULUM STRESS; STATE; SENSOR;
D O I
10.1039/c8cc04919j
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this work, we set out to develop an endoplasmic reticulum (ER) directed ESIPT-based ONOO- ratiometric fluorescent probe (ABAH-LW). ABAH-LW was synthesized in four steps and found to have a high sensitivity and selectivity towards the detection of ONOO-. ABAH-LW was able to detect low concentrations of ONOO- (limit of detection = 21.4 nM) within seconds producing a ratiometric change in fluorescence intensity. ABAH-LW further demonstrated the ability to ratiometrically image endogenous and exogenous ONOO- in HeLa cells. Moreover, co-localization experiments were carried out using commercially available ER-Tracker Red, Lyso-Tracker Red and Mito-Tracker-Red, which were co-stained with ABAH-LW in HeLa cells. For ER-Tracker Red, Pearson's correlation co-efficient of 0.93 was determined and 3D surface plot analysis illustrated a large overlap between ABAH-LW and ER-Tracker Red using both red and blue channels. In addition some co-localisation with Mito-Tracker Red and ABAH-LW was observed (0.73).
引用
收藏
页码:9953 / 9956
页数:4
相关论文
共 50 条
  • [41] A coumarin-indole-based near-infrared ratiometric pH probe for intracellular fluorescence imaging
    Liu, Xiao-Dong
    Xu, Ying
    Sun, Ru
    Xu, Yu-Jie
    Lu, Jian-Mei
    Ge, Jian-Feng
    ANALYST, 2013, 138 (21) : 6542 - 6550
  • [42] Design and Synthesis of ESIPT-Based Imidazole Derivatives for Cell Imaging
    Gul, Sergen
    Acikgoz, Eda
    Cakir, Mustafa
    Menges, Nurettin
    ACS OMEGA, 2024, 9 (23): : 24291 - 24298
  • [43] Novel isophorone fluorescent probe for ratiometric peroxynitrite imaging in vivo
    Zhang, Deling
    Lin, Bin
    Han, Yifeng
    SENSORS AND ACTUATORS B-CHEMICAL, 2024, 421
  • [44] In vitro and in vivo imaging of peroxynitrite by a ratiometric boronatebased fluorescent probe
    Palanisamy, Sathyadevi
    Wu, Pei-Yu
    Wu, Shou-Cheng
    Chen, Yu-Jen
    Tzou, Shey-Cherng
    Wang, Chih-Hong
    Chen, Chiao-Yun
    Wang, Yun-Ming
    BIOSENSORS & BIOELECTRONICS, 2017, 91 : 849 - 856
  • [45] A profluorescent ratiometric probe for intracellular pH imaging
    Zhang, Qingqing
    Zhou, Ming
    TALANTA, 2015, 131 : 666 - 671
  • [46] A ratiometric pH probe for intracellular pH imaging
    Chao, Jianbin
    Liu, Yuhong
    Sun, Jinyu
    Fan, Li
    Zhang, Yongbin
    Tong, Hongbo
    Li, Zhiqing
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 427 - 433
  • [47] An ESIPT-based mitochondria-targeted ratiometric and NIR-emitting fluorescent probe for hydrogen peroxide and its bioimaging in living cells
    Tang, Lijun
    Tian, Mingyu
    Chen, Haibo
    Yan, Xiaomei
    Zhong, Keli
    Bian, Yanjiang
    DYES AND PIGMENTS, 2018, 158 : 482 - 489
  • [48] An ESIPT-based fluorescent probe for the determination of hypochlorous acid (HClO): mechanism study and its application in cell imaging
    He, Yonghuan
    Xu, Yan
    Shang, Yuting
    Zheng, Shuwen
    Chen, Weihua
    Pang, Yi
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (27) : 7007 - 7017
  • [49] An ESIPT-based fluorescent probe for the determination of hypochlorous acid (HClO): mechanism study and its application in cell imaging
    Yonghuan He
    Yan Xu
    Yuting Shang
    Shuwen Zheng
    Weihua Chen
    Yi Pang
    Analytical and Bioanalytical Chemistry, 2018, 410 : 7007 - 7017
  • [50] Naphthylamine-based ratiometric fluorescence probe with a large Stokes shift for monitoring mitochondrial peroxynitrite
    Guo, Bingpeng
    Sa, Honghan
    Zhang, Peng
    Hao, Guiwen
    Li, Mengyu
    Jiang, Qingqing
    Li, Baoying
    Shu, Wei
    Shao, Changxiang
    DYES AND PIGMENTS, 2024, 221